Standard

Calorimetry of the CMD-3 detector. / Akhmetshin, R. R.; Anisenkov, A. V.; Aulchenko, V. M. et al.

In: Journal of Physics: Conference Series, Vol. 928, No. 1, 012011, 27.11.2017.

Research output: Contribution to journalArticlepeer-review

Harvard

Akhmetshin, RR, Anisenkov, AV, Aulchenko, VM, Bashtovoy, NS, Epifanov, DA, Epshteyn, LB, Erofeev, AL, Grebenuk, AA, Grigoriev, DN, Kazanin, VF, Kovalenko, OA, Kozyrev, AN, Kuzmenko, AE, Kuzmin, AS, Logashenko, IB, Mikhailov, KY, Okhapkin, VS, Razuvaev, GP, Ruban, AA, Shebalin, VE, Shwartz, BA, Titov, VM, Talyshev, AA & Yudin, YV 2017, 'Calorimetry of the CMD-3 detector', Journal of Physics: Conference Series, vol. 928, no. 1, 012011. https://doi.org/10.1088/1742-6596/928/1/012011

APA

Akhmetshin, R. R., Anisenkov, A. V., Aulchenko, V. M., Bashtovoy, N. S., Epifanov, D. A., Epshteyn, L. B., Erofeev, A. L., Grebenuk, A. A., Grigoriev, D. N., Kazanin, V. F., Kovalenko, O. A., Kozyrev, A. N., Kuzmenko, A. E., Kuzmin, A. S., Logashenko, I. B., Mikhailov, K. Y., Okhapkin, V. S., Razuvaev, G. P., Ruban, A. A., ... Yudin, Y. V. (2017). Calorimetry of the CMD-3 detector. Journal of Physics: Conference Series, 928(1), [012011]. https://doi.org/10.1088/1742-6596/928/1/012011

Vancouver

Akhmetshin RR, Anisenkov AV, Aulchenko VM, Bashtovoy NS, Epifanov DA, Epshteyn LB et al. Calorimetry of the CMD-3 detector. Journal of Physics: Conference Series. 2017 Nov 27;928(1):012011. doi: 10.1088/1742-6596/928/1/012011

Author

Akhmetshin, R. R. ; Anisenkov, A. V. ; Aulchenko, V. M. et al. / Calorimetry of the CMD-3 detector. In: Journal of Physics: Conference Series. 2017 ; Vol. 928, No. 1.

BibTeX

@article{d53888c7ca8449b4a86fcd01938beff8,
title = "Calorimetry of the CMD-3 detector",
abstract = "The CMD-3 detector has been collecting data since 2010 at the e + e - collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e + e - annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.",
keywords = "VEPP-2000, E(+)E(-), PHYSICS",
author = "Akhmetshin, {R. R.} and Anisenkov, {A. V.} and Aulchenko, {V. M.} and Bashtovoy, {N. S.} and Epifanov, {D. A.} and Epshteyn, {L. B.} and Erofeev, {A. L.} and Grebenuk, {A. A.} and Grigoriev, {D. N.} and Kazanin, {V. F.} and Kovalenko, {O. A.} and Kozyrev, {A. N.} and Kuzmenko, {A. E.} and Kuzmin, {A. S.} and Logashenko, {I. B.} and Mikhailov, {K. Yu} and Okhapkin, {V. S.} and Razuvaev, {G. P.} and Ruban, {A. A.} and Shebalin, {V. E.} and Shwartz, {B. A.} and Titov, {V. M.} and Talyshev, {A. A.} and Yudin, {Yu V.}",
year = "2017",
month = nov,
day = "27",
doi = "10.1088/1742-6596/928/1/012011",
language = "English",
volume = "928",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Calorimetry of the CMD-3 detector

AU - Akhmetshin, R. R.

AU - Anisenkov, A. V.

AU - Aulchenko, V. M.

AU - Bashtovoy, N. S.

AU - Epifanov, D. A.

AU - Epshteyn, L. B.

AU - Erofeev, A. L.

AU - Grebenuk, A. A.

AU - Grigoriev, D. N.

AU - Kazanin, V. F.

AU - Kovalenko, O. A.

AU - Kozyrev, A. N.

AU - Kuzmenko, A. E.

AU - Kuzmin, A. S.

AU - Logashenko, I. B.

AU - Mikhailov, K. Yu

AU - Okhapkin, V. S.

AU - Razuvaev, G. P.

AU - Ruban, A. A.

AU - Shebalin, V. E.

AU - Shwartz, B. A.

AU - Titov, V. M.

AU - Talyshev, A. A.

AU - Yudin, Yu V.

PY - 2017/11/27

Y1 - 2017/11/27

N2 - The CMD-3 detector has been collecting data since 2010 at the e + e - collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e + e - annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.

AB - The CMD-3 detector has been collecting data since 2010 at the e + e - collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e + e - annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.

KW - VEPP-2000

KW - E(+)E(-)

KW - PHYSICS

UR - http://www.scopus.com/inward/record.url?scp=85039427189&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/928/1/012011

DO - 10.1088/1742-6596/928/1/012011

M3 - Article

AN - SCOPUS:85039427189

VL - 928

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012011

ER -

ID: 9643436