Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Calorimetry of the CMD-3 detector. / Akhmetshin, R. R.; Anisenkov, A. V.; Aulchenko, V. M. и др.
в: Journal of Physics: Conference Series, Том 928, № 1, 012011, 27.11.2017.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Calorimetry of the CMD-3 detector
AU - Akhmetshin, R. R.
AU - Anisenkov, A. V.
AU - Aulchenko, V. M.
AU - Bashtovoy, N. S.
AU - Epifanov, D. A.
AU - Epshteyn, L. B.
AU - Erofeev, A. L.
AU - Grebenuk, A. A.
AU - Grigoriev, D. N.
AU - Kazanin, V. F.
AU - Kovalenko, O. A.
AU - Kozyrev, A. N.
AU - Kuzmenko, A. E.
AU - Kuzmin, A. S.
AU - Logashenko, I. B.
AU - Mikhailov, K. Yu
AU - Okhapkin, V. S.
AU - Razuvaev, G. P.
AU - Ruban, A. A.
AU - Shebalin, V. E.
AU - Shwartz, B. A.
AU - Titov, V. M.
AU - Talyshev, A. A.
AU - Yudin, Yu V.
PY - 2017/11/27
Y1 - 2017/11/27
N2 - The CMD-3 detector has been collecting data since 2010 at the e + e - collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e + e - annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.
AB - The CMD-3 detector has been collecting data since 2010 at the e + e - collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e + e - annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.
KW - VEPP-2000
KW - E(+)E(-)
KW - PHYSICS
UR - http://www.scopus.com/inward/record.url?scp=85039427189&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/928/1/012011
DO - 10.1088/1742-6596/928/1/012011
M3 - Article
AN - SCOPUS:85039427189
VL - 928
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
SN - 1742-6588
IS - 1
M1 - 012011
ER -
ID: 9643436