Research output: Contribution to journal › Article › peer-review
Separation of the Process (Formula presented.) by Means of time Measurements in the Caloriment. / Achasov, M. N.; Barnyakov, A. Yu; Baykov, A. A. et al.
In: Physics of Atomic Nuclei, Vol. 83, No. 6, 11.2020, p. 937-939.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Separation of the Process (Formula presented.) by Means of time Measurements in the Caloriment
AU - Achasov, M. N.
AU - Barnyakov, A. Yu
AU - Baykov, A. A.
AU - Beloborodov, K. I.
AU - Berdyugin, A. V.
AU - Bogdanchikov, A. G.
AU - Botov, A. A.
AU - Golubev, V. B.
AU - Dimova, T. V.
AU - Druzhinin, V. P.
AU - Zhabin, V. N.
AU - Zhulanov, V. V.
AU - Kardapoltsev, L. V.
AU - Kovrizhin, D. P.
AU - Korol, A. A.
AU - Kupich, A. S.
AU - Martin, K. A.
AU - Melnikova, N. A.
AU - Muchnoi, N. Yu
AU - Obrazovsky, A. E.
AU - Pakhtusova, E. V.
AU - Pugachev, K. V.
AU - Savchenko, Ya S.
AU - Serednyakov, S. I.
AU - Silagadze, Z. K.
AU - Surin, I. K.
AU - Usov, Yu V.
AU - Kharlamov, A. G.
AU - Shtol, D. A.
N1 - Funding Information: This work was supported in part by Russian Foundation for Basic Research (project no. 18-02-00147A). Publisher Copyright: © 2020, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2020/11
Y1 - 2020/11
N2 - In the experiment with the SND detector at the VEPP-2000 (Formula presented.) collider, events of the process (Formula presented.) were separated via measuring, in each counter of the multichannel calorimeter based on 1640 NaI(Tl) crystals, the time of delay of the signal from nonrelativistic antineutrons. The time resolution for events of the process (Formula presented.) was 0.8 ns. The measured time spectrum of delays of the signal from antineutrons in the calorimeter at the c.m. energy of 1902 MeV agrees with the results of calculations.
AB - In the experiment with the SND detector at the VEPP-2000 (Formula presented.) collider, events of the process (Formula presented.) were separated via measuring, in each counter of the multichannel calorimeter based on 1640 NaI(Tl) crystals, the time of delay of the signal from nonrelativistic antineutrons. The time resolution for events of the process (Formula presented.) was 0.8 ns. The measured time spectrum of delays of the signal from antineutrons in the calorimeter at the c.m. energy of 1902 MeV agrees with the results of calculations.
UR - http://www.scopus.com/inward/record.url?scp=85100838580&partnerID=8YFLogxK
U2 - 10.1134/S1063778820060010
DO - 10.1134/S1063778820060010
M3 - Article
AN - SCOPUS:85100838580
VL - 83
SP - 937
EP - 939
JO - Physics of Atomic Nuclei
JF - Physics of Atomic Nuclei
SN - 1063-7788
IS - 6
ER -
ID: 27865288