Standard

Energy calibration of the barrel calorimeter of the CMD-3 detector. / Anisenkov, A. V.; Aulchenko, V. M.; Bashtovoy, N. S. et al.

In: Journal of Instrumentation, Vol. 12, No. 4, 04011, 10.04.2017.

Research output: Contribution to journalArticlepeer-review

Harvard

Anisenkov, AV, Aulchenko, VM, Bashtovoy, NS, Bondar, AE, Grebenuk, AA, Epifanov, DA, Epshteyn, LB, Erofeev, AL, Kovalenko, OA, Kozyrev, AN, Kuzmin, AS, Mikhailov, KY, Logashenko, IB, Razuvaev, GP, Ruban, AA, Shebalin, VE, Shwartz, BA, Talyshev, AA, Titov, VM & Yudin, YV 2017, 'Energy calibration of the barrel calorimeter of the CMD-3 detector', Journal of Instrumentation, vol. 12, no. 4, 04011. https://doi.org/10.1088/1748-0221/12/04/P04011

APA

Anisenkov, A. V., Aulchenko, V. M., Bashtovoy, N. S., Bondar, A. E., Grebenuk, A. A., Epifanov, D. A., Epshteyn, L. B., Erofeev, A. L., Kovalenko, O. A., Kozyrev, A. N., Kuzmin, A. S., Mikhailov, K. Y., Logashenko, I. B., Razuvaev, G. P., Ruban, A. A., Shebalin, V. E., Shwartz, B. A., Talyshev, A. A., Titov, V. M., & Yudin, Y. V. (2017). Energy calibration of the barrel calorimeter of the CMD-3 detector. Journal of Instrumentation, 12(4), [04011]. https://doi.org/10.1088/1748-0221/12/04/P04011

Vancouver

Anisenkov AV, Aulchenko VM, Bashtovoy NS, Bondar AE, Grebenuk AA, Epifanov DA et al. Energy calibration of the barrel calorimeter of the CMD-3 detector. Journal of Instrumentation. 2017 Apr 10;12(4):04011. doi: 10.1088/1748-0221/12/04/P04011

Author

Anisenkov, A. V. ; Aulchenko, V. M. ; Bashtovoy, N. S. et al. / Energy calibration of the barrel calorimeter of the CMD-3 detector. In: Journal of Instrumentation. 2017 ; Vol. 12, No. 4.

BibTeX

@article{8d78a1501ded4b36bc3ebf0837492dbb,
title = "Energy calibration of the barrel calorimeter of the CMD-3 detector",
abstract = "The VEPP-2000 e+e- collider has been operated in the Budker Institute of Nuclear Physics since 2010. Experiments are carried out with two detectors CMD-3 and SND. The calorimetry at the CMD-3 detector is based on three subsystems, two coaxial barrel calorimeters - Liquid Xenon calorimeter and crystal CsI calorimeter, and end cap calorimeter with BGO crystals. This paper describes the procedures of the energy calibration of the combined barrel calorimeter of the CMD-3 detector.",
keywords = "Calorimeters, Detector alignment and calibration methods (lasers, sources, particlebeams), Detector alignment and calibration methods (lasers, sources, particle-beams), COLLIDER, VEPP-2000",
author = "Anisenkov, {A. V.} and Aulchenko, {V. M.} and Bashtovoy, {N. S.} and Bondar, {A. E.} and Grebenuk, {A. A.} and Epifanov, {D. A.} and Epshteyn, {L. B.} and Erofeev, {A. L.} and Kovalenko, {O. A.} and Kozyrev, {A. N.} and Kuzmin, {A. S.} and Mikhailov, {K. Yu} and Logashenko, {I. B.} and Razuvaev, {G. P.} and Ruban, {A. A.} and Shebalin, {V. E.} and Shwartz, {B. A.} and Talyshev, {A. A.} and Titov, {V. M.} and Yudin, {Yu V.}",
note = "Publisher Copyright: {\textcopyright} 2017 IOP Publishing Ltd and Sissa Medialab srl.",
year = "2017",
month = apr,
day = "10",
doi = "10.1088/1748-0221/12/04/P04011",
language = "English",
volume = "12",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "4",

}

RIS

TY - JOUR

T1 - Energy calibration of the barrel calorimeter of the CMD-3 detector

AU - Anisenkov, A. V.

AU - Aulchenko, V. M.

AU - Bashtovoy, N. S.

AU - Bondar, A. E.

AU - Grebenuk, A. A.

AU - Epifanov, D. A.

AU - Epshteyn, L. B.

AU - Erofeev, A. L.

AU - Kovalenko, O. A.

AU - Kozyrev, A. N.

AU - Kuzmin, A. S.

AU - Mikhailov, K. Yu

AU - Logashenko, I. B.

AU - Razuvaev, G. P.

AU - Ruban, A. A.

AU - Shebalin, V. E.

AU - Shwartz, B. A.

AU - Talyshev, A. A.

AU - Titov, V. M.

AU - Yudin, Yu V.

N1 - Publisher Copyright: © 2017 IOP Publishing Ltd and Sissa Medialab srl.

PY - 2017/4/10

Y1 - 2017/4/10

N2 - The VEPP-2000 e+e- collider has been operated in the Budker Institute of Nuclear Physics since 2010. Experiments are carried out with two detectors CMD-3 and SND. The calorimetry at the CMD-3 detector is based on three subsystems, two coaxial barrel calorimeters - Liquid Xenon calorimeter and crystal CsI calorimeter, and end cap calorimeter with BGO crystals. This paper describes the procedures of the energy calibration of the combined barrel calorimeter of the CMD-3 detector.

AB - The VEPP-2000 e+e- collider has been operated in the Budker Institute of Nuclear Physics since 2010. Experiments are carried out with two detectors CMD-3 and SND. The calorimetry at the CMD-3 detector is based on three subsystems, two coaxial barrel calorimeters - Liquid Xenon calorimeter and crystal CsI calorimeter, and end cap calorimeter with BGO crystals. This paper describes the procedures of the energy calibration of the combined barrel calorimeter of the CMD-3 detector.

KW - Calorimeters

KW - Detector alignment and calibration methods (lasers, sources, particlebeams)

KW - Detector alignment and calibration methods (lasers, sources, particle-beams)

KW - COLLIDER

KW - VEPP-2000

UR - http://www.scopus.com/inward/record.url?scp=85019434090&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/12/04/P04011

DO - 10.1088/1748-0221/12/04/P04011

M3 - Article

AN - SCOPUS:85019434090

VL - 12

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 4

M1 - 04011

ER -

ID: 8835803