Standard

Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition. / Shvets, V. A.; Marin, D. V.; Remesnik, V. G. и др.

в: Optics and Spectroscopy, Том 128, № 12, 12.2020, стр. 1948-1953.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Shvets, VA, Marin, DV, Remesnik, VG, Azarov, IA, Yakushev, MV & Rykhlitskii, SV 2020, 'Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition', Optics and Spectroscopy, Том. 128, № 12, стр. 1948-1953. https://doi.org/10.1134/S0030400X20121042

APA

Shvets, V. A., Marin, D. V., Remesnik, V. G., Azarov, I. A., Yakushev, M. V., & Rykhlitskii, S. V. (2020). Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition. Optics and Spectroscopy, 128(12), 1948-1953. https://doi.org/10.1134/S0030400X20121042

Vancouver

Shvets VA, Marin DV, Remesnik VG, Azarov IA, Yakushev MV, Rykhlitskii SV. Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition. Optics and Spectroscopy. 2020 дек.;128(12):1948-1953. doi: 10.1134/S0030400X20121042

Author

Shvets, V. A. ; Marin, D. V. ; Remesnik, V. G. и др. / Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition. в: Optics and Spectroscopy. 2020 ; Том 128, № 12. стр. 1948-1953.

BibTeX

@article{e1df16a23a9b479e8df7b0f54b89f8d7,
title = "Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition",
abstract = "A parametric model describing the spectra of optical constants n(λ) and k(λ) of a Hg1 – xCdxTe (MCT) solid solution for the x values in the range from 0.2 to 0.4 is developed. This model is based on empirical data measured in situ during the epitaxial growth of solid-solution layers. Several versions of application of the obtained model for in situ real-time determination of the MCT composition have been considered. A technique for determining the composition using spectral ellipsometric measurements is proposed, which ensures the error of no more than δx = ±0.0035.",
keywords = "compound composition, ellipsometry, in situ monitoring, mercury–cadmium–tellurium, optical constant spectra",
author = "Shvets, {V. A.} and Marin, {D. V.} and Remesnik, {V. G.} and Azarov, {I. A.} and Yakushev, {M. V.} and Rykhlitskii, {S. V.}",
note = "Funding Information: This study was supported by the Ministry of Science and Higher Education of the Russian Federation (state contract no. 0306-2019-0004) and, in part, the Russian Foundation for Basic Research (project no. 19-29-20053). Publisher Copyright: {\textcopyright} 2020, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.",
year = "2020",
month = dec,
doi = "10.1134/S0030400X20121042",
language = "English",
volume = "128",
pages = "1948--1953",
journal = "Optics and Spectroscopy (English translation of Optika i Spektroskopiya)",
issn = "0030-400X",
publisher = "Maik Nauka Publishing / Springer SBM",
number = "12",

}

RIS

TY - JOUR

T1 - Parametric Model of the Optical Constant Spectra of Hg1 –xCdxTe and Determination of the Compound Composition

AU - Shvets, V. A.

AU - Marin, D. V.

AU - Remesnik, V. G.

AU - Azarov, I. A.

AU - Yakushev, M. V.

AU - Rykhlitskii, S. V.

N1 - Funding Information: This study was supported by the Ministry of Science and Higher Education of the Russian Federation (state contract no. 0306-2019-0004) and, in part, the Russian Foundation for Basic Research (project no. 19-29-20053). Publisher Copyright: © 2020, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.

PY - 2020/12

Y1 - 2020/12

N2 - A parametric model describing the spectra of optical constants n(λ) and k(λ) of a Hg1 – xCdxTe (MCT) solid solution for the x values in the range from 0.2 to 0.4 is developed. This model is based on empirical data measured in situ during the epitaxial growth of solid-solution layers. Several versions of application of the obtained model for in situ real-time determination of the MCT composition have been considered. A technique for determining the composition using spectral ellipsometric measurements is proposed, which ensures the error of no more than δx = ±0.0035.

AB - A parametric model describing the spectra of optical constants n(λ) and k(λ) of a Hg1 – xCdxTe (MCT) solid solution for the x values in the range from 0.2 to 0.4 is developed. This model is based on empirical data measured in situ during the epitaxial growth of solid-solution layers. Several versions of application of the obtained model for in situ real-time determination of the MCT composition have been considered. A technique for determining the composition using spectral ellipsometric measurements is proposed, which ensures the error of no more than δx = ±0.0035.

KW - compound composition

KW - ellipsometry

KW - in situ monitoring

KW - mercury–cadmium–tellurium

KW - optical constant spectra

UR - http://www.scopus.com/inward/record.url?scp=85102765526&partnerID=8YFLogxK

U2 - 10.1134/S0030400X20121042

DO - 10.1134/S0030400X20121042

M3 - Article

AN - SCOPUS:85102765526

VL - 128

SP - 1948

EP - 1953

JO - Optics and Spectroscopy (English translation of Optika i Spektroskopiya)

JF - Optics and Spectroscopy (English translation of Optika i Spektroskopiya)

SN - 0030-400X

IS - 12

ER -

ID: 28134222