Shilov, AM, Zagainov, SD, Kuzovnikov, VM, Batrakov, AY, Uliyanov, EY & Mandrueva, AE 2022, Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019. в 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON). Institute of Electrical and Electronics Engineers (IEEE), стр. 1530-1534, 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences, SIBIRCON 2022, Екатеринбург, Российская Федерация, 11.11.2022. https://doi.org/10.1109/sibircon56155.2022.10017078

APA

Shilov, A. M., Zagainov, S. D., Kuzovnikov, V. M., Batrakov, A. Y., Uliyanov, E. Y., & Mandrueva, A. E. (2022). Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019. в 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON) (стр. 1530-1534). Institute of Electrical and Electronics Engineers (IEEE). https://doi.org/10.1109/sibircon56155.2022.10017078

Vancouver

Shilov AM, Zagainov SD, Kuzovnikov VM, Batrakov AY, Uliyanov EY, Mandrueva AE. Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019. в 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON). Institute of Electrical and Electronics Engineers (IEEE). 2022. стр. 1530-1534 doi: 10.1109/sibircon56155.2022.10017078

Author

Shilov, Alexander M. ; Zagainov, Sergey D. ; Kuzovnikov, Viktor M. и др. / Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019. 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON). Institute of Electrical and Electronics Engineers (IEEE), 2022. стр. 1530-1534

BibTeX

@inproceedings{f691c814041f4db28058832ee19088fe,
title = "Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019",
abstract = "The paper describes the composition and characteristics of the State Primary Special Standard unit of capacitance in the frequency range from 1 to 300 MHz GET 107- 2019. The upper frequency limit of the capacitance reproduction of GET 107-2019 is 300 MHz. This was achieved as a result of the development of a reference installation with an operating frequency of 300 MHz. The paper considers the principle of operation of the installation and algorithms for processing the measurements. The relative systematic residual error of GET 107-2019 is 5•10 -5 -1•10 -3 depending on the operating frequency, the relative standard deviation of the measurement result when reproducing the unit is 3•10 -6 -3•10 -4 , which exceeds the capabilities of national standards of other countries. The State Verification Scheme for measuring electrical capacitance in the frequency range 1-300 MHz has been developed and approved. GET 107-2019, as well as the subordinate standards and measuring instruments are widely used in micro- and nano-electronics, biomedicine, radio electronic industry, instrumentation, in the development and production of modern materials and equipment.",
author = "Shilov, {Alexander M.} and Zagainov, {Sergey D.} and Kuzovnikov, {Viktor M.} and Batrakov, {Alexander Yu.} and Uliyanov, {Eugeniy Yu.} and Mandrueva, {Anastasiya Ev.}",
year = "2022",
doi = "10.1109/sibircon56155.2022.10017078",
language = "English",
isbn = "9781665464802",
pages = "1530--1534",
booktitle = "2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON)",
publisher = "Institute of Electrical and Electronics Engineers (IEEE)",
note = "2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences, SIBIRCON 2022, SIBIRCON 2022 ; Conference date: 11-11-2022 Through 13-11-2022",
url = "https://sibircon.ieeesiberia.org/",

}

RIS

TY - GEN

T1 - Improved State Primary Special Standard for the Unit of Capacitance in the Frequency Range from 1 to 300 MHz GET 107-2019

AU - Shilov, Alexander M.

AU - Zagainov, Sergey D.

AU - Kuzovnikov, Viktor M.

AU - Batrakov, Alexander Yu.

AU - Uliyanov, Eugeniy Yu.

AU - Mandrueva, Anastasiya Ev.

PY - 2022

Y1 - 2022

N2 - The paper describes the composition and characteristics of the State Primary Special Standard unit of capacitance in the frequency range from 1 to 300 MHz GET 107- 2019. The upper frequency limit of the capacitance reproduction of GET 107-2019 is 300 MHz. This was achieved as a result of the development of a reference installation with an operating frequency of 300 MHz. The paper considers the principle of operation of the installation and algorithms for processing the measurements. The relative systematic residual error of GET 107-2019 is 5•10 -5 -1•10 -3 depending on the operating frequency, the relative standard deviation of the measurement result when reproducing the unit is 3•10 -6 -3•10 -4 , which exceeds the capabilities of national standards of other countries. The State Verification Scheme for measuring electrical capacitance in the frequency range 1-300 MHz has been developed and approved. GET 107-2019, as well as the subordinate standards and measuring instruments are widely used in micro- and nano-electronics, biomedicine, radio electronic industry, instrumentation, in the development and production of modern materials and equipment.

AB - The paper describes the composition and characteristics of the State Primary Special Standard unit of capacitance in the frequency range from 1 to 300 MHz GET 107- 2019. The upper frequency limit of the capacitance reproduction of GET 107-2019 is 300 MHz. This was achieved as a result of the development of a reference installation with an operating frequency of 300 MHz. The paper considers the principle of operation of the installation and algorithms for processing the measurements. The relative systematic residual error of GET 107-2019 is 5•10 -5 -1•10 -3 depending on the operating frequency, the relative standard deviation of the measurement result when reproducing the unit is 3•10 -6 -3•10 -4 , which exceeds the capabilities of national standards of other countries. The State Verification Scheme for measuring electrical capacitance in the frequency range 1-300 MHz has been developed and approved. GET 107-2019, as well as the subordinate standards and measuring instruments are widely used in micro- and nano-electronics, biomedicine, radio electronic industry, instrumentation, in the development and production of modern materials and equipment.

UR - https://www.scopus.com/inward/record.url?eid=2-s2.0-85147529053&partnerID=40&md5=b59157f79c7ac8bb93af01536559affc

UR - https://www.mendeley.com/catalogue/ba25c31c-ee1b-3ab8-b9e9-fce329b730b6/

U2 - 10.1109/sibircon56155.2022.10017078

DO - 10.1109/sibircon56155.2022.10017078

M3 - Conference contribution

SN - 9781665464802

SP - 1530

EP - 1534

BT - 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON)

PB - Institute of Electrical and Electronics Engineers (IEEE)

T2 - 2022 IEEE International Multi-Conference on Engineering, Computer and Information Sciences, SIBIRCON 2022

Y2 - 11 November 2022 through 13 November 2022

ER -

ID: 45973286