Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards. / Ivanova, Y. A.; Kudryavtsev, A. L.; Serebrennikova, P. S. и др.
в: Journal of Structural Chemistry, Том 66, № 10, 20, 08.11.2025, стр. 2225-2238.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards
AU - Ivanova, Y. A.
AU - Kudryavtsev, A. L.
AU - Serebrennikova, P. S.
AU - Gromilov, S. A.
N1 - Ivanova, Y.A., Kudryavtsev, A.L., Serebrennikova, P.S. et al. Accounting the Eccentricity of a Polycrystalline Sample in the Debye–Scherrer Scheme. Certification of a New Y2O3 XRD Standards. J. Struct. Chem. 66, 2225–2238 (2025). https://doi.org/10.1134/S0022476625100208 This study was funded by the Russian Science Foundation and the Government of the Novosibirsk region (project No. 24-22-20017, https://rscf.ru/project/24-22-20017/).
PY - 2025/11/8
Y1 - 2025/11/8
N2 - Issues related to the procedure of optimizing the calibration of modern area-detector diffractometers using reference single crystals are considered. It is shown that the accuracy of measuring the unit cell parameters (UCPs) of polycrystalline samples in the Debye–Scherrer scheme can be improved by considering the eccentricity. The procedure is tested on a CeO2 polycrystalline sample (SRM674b). The value obtained for the cubic unit cell parameter a = 5.4117(2) Å differs from the reference one by 0.0002 Å, in agreement with the experiment′s absolute error. The XRD certification of a promising Y2O3 XRD standard is performed (TU 48-4-524-90; ItO-V grade; 99.999% purity; cubic unit cell parameter a is 10.6047(3) Å).
AB - Issues related to the procedure of optimizing the calibration of modern area-detector diffractometers using reference single crystals are considered. It is shown that the accuracy of measuring the unit cell parameters (UCPs) of polycrystalline samples in the Debye–Scherrer scheme can be improved by considering the eccentricity. The procedure is tested on a CeO2 polycrystalline sample (SRM674b). The value obtained for the cubic unit cell parameter a = 5.4117(2) Å differs from the reference one by 0.0002 Å, in agreement with the experiment′s absolute error. The XRD certification of a promising Y2O3 XRD standard is performed (TU 48-4-524-90; ItO-V grade; 99.999% purity; cubic unit cell parameter a is 10.6047(3) Å).
KW - XRD
KW - accuracy
KW - area detector
KW - calibration
KW - eccentricity
KW - reference
KW - small crystals
KW - unit cell parameters
KW - XRD
KW - area detector
KW - calibration
KW - small crystals
KW - unit cell parameters
KW - accuracy
KW - reference
KW - eccentricity
UR - https://www.scopus.com/pages/publications/105021234340
UR - https://elibrary.ru/item.asp?id=83185964
UR - https://elibrary.ru/item.asp?id=83134053
UR - https://www.mendeley.com/catalogue/df1ac443-02fc-34fe-b731-5675fd6c3736/
U2 - 10.1134/S0022476625100208
DO - 10.1134/S0022476625100208
M3 - Article
VL - 66
SP - 2225
EP - 2238
JO - Journal of Structural Chemistry
JF - Journal of Structural Chemistry
SN - 0022-4766
IS - 10
M1 - 20
ER -
ID: 72580071