Standard

Test of microchannel plates in magnetic fields up to 4.5 T. / Barnyakov, A. Yu; Barnyakov, M. Yu; Prisekin, V. G. et al.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 845, 11.02.2017, p. 588-590.

Research output: Contribution to journalArticlepeer-review

Harvard

Barnyakov, AY, Barnyakov, MY, Prisekin, VG, Karpov, SV & Katcin, AA 2017, 'Test of microchannel plates in magnetic fields up to 4.5 T', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 845, pp. 588-590. https://doi.org/10.1016/j.nima.2016.05.131

APA

Barnyakov, A. Y., Barnyakov, M. Y., Prisekin, V. G., Karpov, S. V., & Katcin, A. A. (2017). Test of microchannel plates in magnetic fields up to 4.5 T. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 845, 588-590. https://doi.org/10.1016/j.nima.2016.05.131

Vancouver

Barnyakov AY, Barnyakov MY, Prisekin VG, Karpov SV, Katcin AA. Test of microchannel plates in magnetic fields up to 4.5 T. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2017 Feb 11;845:588-590. doi: 10.1016/j.nima.2016.05.131

Author

Barnyakov, A. Yu ; Barnyakov, M. Yu ; Prisekin, V. G. et al. / Test of microchannel plates in magnetic fields up to 4.5 T. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2017 ; Vol. 845. pp. 588-590.

BibTeX

@article{fd96c16e1e67484a9576691d5fbcfca5,
title = "Test of microchannel plates in magnetic fields up to 4.5 T",
abstract = "Detectors based on microchannel plates (MCP) can provide high time resolution and are able to operate in high magnetic field. An experimental setup based on a superconductive solenoid with 120 mm bore was created in BINP. The influence of magnetic field up to 4.5 T on the MCP photomultiplier parameters was studied. Several types of photodetectors produced in Novosibirsk were tested. Results of time resolution measurements, dependencies of gain and photon detection efficiency on magnetic field are presented. (C) 2016 Elsevier B.V. All rights reserved.",
keywords = "Magnetic field, Microchannel plate, Photomultiplier, PMT, Time resolution, PHOTOTUBES",
author = "Barnyakov, {A. Yu} and Barnyakov, {M. Yu} and Prisekin, {V. G.} and Karpov, {S. V.} and Katcin, {A. A.}",
note = "Publisher Copyright: {\textcopyright} 2016 Elsevier B.V.",
year = "2017",
month = feb,
day = "11",
doi = "10.1016/j.nima.2016.05.131",
language = "English",
volume = "845",
pages = "588--590",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",

}

RIS

TY - JOUR

T1 - Test of microchannel plates in magnetic fields up to 4.5 T

AU - Barnyakov, A. Yu

AU - Barnyakov, M. Yu

AU - Prisekin, V. G.

AU - Karpov, S. V.

AU - Katcin, A. A.

N1 - Publisher Copyright: © 2016 Elsevier B.V.

PY - 2017/2/11

Y1 - 2017/2/11

N2 - Detectors based on microchannel plates (MCP) can provide high time resolution and are able to operate in high magnetic field. An experimental setup based on a superconductive solenoid with 120 mm bore was created in BINP. The influence of magnetic field up to 4.5 T on the MCP photomultiplier parameters was studied. Several types of photodetectors produced in Novosibirsk were tested. Results of time resolution measurements, dependencies of gain and photon detection efficiency on magnetic field are presented. (C) 2016 Elsevier B.V. All rights reserved.

AB - Detectors based on microchannel plates (MCP) can provide high time resolution and are able to operate in high magnetic field. An experimental setup based on a superconductive solenoid with 120 mm bore was created in BINP. The influence of magnetic field up to 4.5 T on the MCP photomultiplier parameters was studied. Several types of photodetectors produced in Novosibirsk were tested. Results of time resolution measurements, dependencies of gain and photon detection efficiency on magnetic field are presented. (C) 2016 Elsevier B.V. All rights reserved.

KW - Magnetic field

KW - Microchannel plate

KW - Photomultiplier

KW - PMT

KW - Time resolution

KW - PHOTOTUBES

UR - http://www.scopus.com/inward/record.url?scp=84973467781&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2016.05.131

DO - 10.1016/j.nima.2016.05.131

M3 - Article

AN - SCOPUS:84973467781

VL - 845

SP - 588

EP - 590

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

ER -

ID: 8683446