Research output: Contribution to journal › Article › peer-review
Development of data acquisition system for Belle II electromagnetic calorimeter. / Aulchenko, V.; Bobrov, A.; Cheon, B. G. et al.
In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 1030, 166468, 01.05.2022.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Development of data acquisition system for Belle II electromagnetic calorimeter
AU - Aulchenko, V.
AU - Bobrov, A.
AU - Cheon, B. G.
AU - Kuzmin, A.
AU - Longo, S.
AU - Matvienko, D.
AU - Miyabayashi, K.
AU - Nakamura, I.
AU - Nakao, M.
AU - Remnev, M.
AU - Roney, J. M.
AU - Shebalin, V.
AU - Shwartz, B.
AU - Unno, Y.
AU - Usov, Yu V.
AU - Vinokurova, A.
AU - Yamada, S.
AU - Zhulanov, V.
N1 - Funding Information: We are very grateful to the staff of KEK and collaborating institutions for their contributions to the present work. We acknowledge support from Ministry of Science and High Education of the Russian Federation . Publisher Copyright: © 2022 Elsevier B.V.
PY - 2022/5/1
Y1 - 2022/5/1
N2 - The electromagnetic calorimeter (ECL) is one of the primary subsystems of the Belle II detector, used to measure the direction and momentum of photons in a wide energy range. The ECL and its data acquisition system include 8736 CsI(Tl) counters and 628 highly configurable modules for data readout. Several features both in the firmware and in the software were implemented to ensure efficient operation during data taking. This paper describes the development of ECL firmware, corresponding configuration, initialization and monitoring software, along with the development of ECL run control.
AB - The electromagnetic calorimeter (ECL) is one of the primary subsystems of the Belle II detector, used to measure the direction and momentum of photons in a wide energy range. The ECL and its data acquisition system include 8736 CsI(Tl) counters and 628 highly configurable modules for data readout. Several features both in the firmware and in the software were implemented to ensure efficient operation during data taking. This paper describes the development of ECL firmware, corresponding configuration, initialization and monitoring software, along with the development of ECL run control.
KW - Belle II
KW - DAQ
KW - Electromagnetic calorimeter
KW - Slow control
UR - http://www.scopus.com/inward/record.url?scp=85125778949&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2022.166468
DO - 10.1016/j.nima.2022.166468
M3 - Article
AN - SCOPUS:85125778949
VL - 1030
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
M1 - 166468
ER -
ID: 35635227