Standard

Detectors to Study Fast-Floating Processes on the SR Beam. / Kudashkin, D. V.; Arakcheev, A. S.; Aulchenko, V. M. et al.

In: Journal of Surface Investigation, Vol. 15, No. 2, 26, 03.2021, p. 371-377.

Research output: Contribution to journalArticlepeer-review

Harvard

Kudashkin, DV, Arakcheev, AS, Aulchenko, VM, Zhulanov, VV, Tolochko, BP & Shekhtman, LI 2021, 'Detectors to Study Fast-Floating Processes on the SR Beam', Journal of Surface Investigation, vol. 15, no. 2, 26, pp. 371-377. https://doi.org/10.1134/S1027451021020269

APA

Vancouver

Kudashkin DV, Arakcheev AS, Aulchenko VM, Zhulanov VV, Tolochko BP, Shekhtman LI. Detectors to Study Fast-Floating Processes on the SR Beam. Journal of Surface Investigation. 2021 Mar;15(2):371-377. 26. doi: 10.1134/S1027451021020269

Author

Kudashkin, D. V. ; Arakcheev, A. S. ; Aulchenko, V. M. et al. / Detectors to Study Fast-Floating Processes on the SR Beam. In: Journal of Surface Investigation. 2021 ; Vol. 15, No. 2. pp. 371-377.

BibTeX

@article{e0658852bf6843298be03da983c433e5,
title = "Detectors to Study Fast-Floating Processes on the SR Beam",
abstract = "This paper describes systematic measurements of the main parameters of the DIMEX-Si silicon microstrip detector prototype, designed to study fast processes in a beam of synchrotron radiation (SR). The dynamic range, spatial resolution and temporal parameters of the detector are estimated. The parameters of the prototype silicon detector are compared with the DIMEX-G gas version. The maximum flux which can be measured by the silicon detector is 40 times higher than that of the gas detector. The spatial resolution of the silicon detector is 130 microns and that of the gas detector is 250 microns. The estimated time resolution of the silicon detector is 15 ns, while for a gas detector this value is about 50 ns. All the characteristics of DIMEX-Si are measured with a cycle time of 25 ns. The results of the first tests of a full-scale silicon detector for diffraction studies, operating in the integrating mode at a speed of up to 2 Mframes/s, are also given. The sensor contains 1024 strips 30 mm long with a step of 50 microns; 512 of these strips are connected to readout electronics based on APC128 ASIC. Each chip contains 128 channels, which consist of a low-noise integrator with 32 analog memory cells. The possibility of signal visualization from single photons and electrons from 109Cd and 90Sr sources is shown.",
keywords = "high-speed processes, SR detectors, synchrotron radiation",
author = "Kudashkin, {D. V.} and Arakcheev, {A. S.} and Aulchenko, {V. M.} and Zhulanov, {V. V.} and Tolochko, {B. P.} and Shekhtman, {L. I.}",
note = "Publisher Copyright: {\textcopyright} 2021, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.",
year = "2021",
month = mar,
doi = "10.1134/S1027451021020269",
language = "English",
volume = "15",
pages = "371--377",
journal = "Journal of Surface Investigation",
issn = "1027-4510",
publisher = "Maik Nauka Publishing / Springer SBM",
number = "2",

}

RIS

TY - JOUR

T1 - Detectors to Study Fast-Floating Processes on the SR Beam

AU - Kudashkin, D. V.

AU - Arakcheev, A. S.

AU - Aulchenko, V. M.

AU - Zhulanov, V. V.

AU - Tolochko, B. P.

AU - Shekhtman, L. I.

N1 - Publisher Copyright: © 2021, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.

PY - 2021/3

Y1 - 2021/3

N2 - This paper describes systematic measurements of the main parameters of the DIMEX-Si silicon microstrip detector prototype, designed to study fast processes in a beam of synchrotron radiation (SR). The dynamic range, spatial resolution and temporal parameters of the detector are estimated. The parameters of the prototype silicon detector are compared with the DIMEX-G gas version. The maximum flux which can be measured by the silicon detector is 40 times higher than that of the gas detector. The spatial resolution of the silicon detector is 130 microns and that of the gas detector is 250 microns. The estimated time resolution of the silicon detector is 15 ns, while for a gas detector this value is about 50 ns. All the characteristics of DIMEX-Si are measured with a cycle time of 25 ns. The results of the first tests of a full-scale silicon detector for diffraction studies, operating in the integrating mode at a speed of up to 2 Mframes/s, are also given. The sensor contains 1024 strips 30 mm long with a step of 50 microns; 512 of these strips are connected to readout electronics based on APC128 ASIC. Each chip contains 128 channels, which consist of a low-noise integrator with 32 analog memory cells. The possibility of signal visualization from single photons and electrons from 109Cd and 90Sr sources is shown.

AB - This paper describes systematic measurements of the main parameters of the DIMEX-Si silicon microstrip detector prototype, designed to study fast processes in a beam of synchrotron radiation (SR). The dynamic range, spatial resolution and temporal parameters of the detector are estimated. The parameters of the prototype silicon detector are compared with the DIMEX-G gas version. The maximum flux which can be measured by the silicon detector is 40 times higher than that of the gas detector. The spatial resolution of the silicon detector is 130 microns and that of the gas detector is 250 microns. The estimated time resolution of the silicon detector is 15 ns, while for a gas detector this value is about 50 ns. All the characteristics of DIMEX-Si are measured with a cycle time of 25 ns. The results of the first tests of a full-scale silicon detector for diffraction studies, operating in the integrating mode at a speed of up to 2 Mframes/s, are also given. The sensor contains 1024 strips 30 mm long with a step of 50 microns; 512 of these strips are connected to readout electronics based on APC128 ASIC. Each chip contains 128 channels, which consist of a low-noise integrator with 32 analog memory cells. The possibility of signal visualization from single photons and electrons from 109Cd and 90Sr sources is shown.

KW - high-speed processes

KW - SR detectors

KW - synchrotron radiation

UR - http://www.scopus.com/inward/record.url?scp=85104612672&partnerID=8YFLogxK

UR - https://www.elibrary.ru/item.asp?id=46026158

U2 - 10.1134/S1027451021020269

DO - 10.1134/S1027451021020269

M3 - Article

AN - SCOPUS:85104612672

VL - 15

SP - 371

EP - 377

JO - Journal of Surface Investigation

JF - Journal of Surface Investigation

SN - 1027-4510

IS - 2

M1 - 26

ER -

ID: 28445937