Standard

Calibration of the calorimeter signal waveform in the SND detector. / Achasov, M. N.; Bogdanchikov, A. G.; Druzhinin, V. P. et al.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 936, 21.08.2019, p. 117-118.

Research output: Contribution to journalReview articlepeer-review

Harvard

Achasov, MN, Bogdanchikov, AG, Druzhinin, VP, Korol, AA, Koshuba, SV, Kovrizhin, DP, Surin, IK, Tekut'ev, AI, Usov, YV & Zhulanov, VV 2019, 'Calibration of the calorimeter signal waveform in the SND detector', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 936, pp. 117-118. https://doi.org/10.1016/j.nima.2018.10.038

APA

Achasov, M. N., Bogdanchikov, A. G., Druzhinin, V. P., Korol, A. A., Koshuba, S. V., Kovrizhin, D. P., Surin, I. K., Tekut'ev, A. I., Usov, Y. V., & Zhulanov, V. V. (2019). Calibration of the calorimeter signal waveform in the SND detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 936, 117-118. https://doi.org/10.1016/j.nima.2018.10.038

Vancouver

Achasov MN, Bogdanchikov AG, Druzhinin VP, Korol AA, Koshuba SV, Kovrizhin DP et al. Calibration of the calorimeter signal waveform in the SND detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 Aug 21;936:117-118. doi: 10.1016/j.nima.2018.10.038

Author

Achasov, M. N. ; Bogdanchikov, A. G. ; Druzhinin, V. P. et al. / Calibration of the calorimeter signal waveform in the SND detector. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 ; Vol. 936. pp. 117-118.

BibTeX

@article{2c76f30918e14260bae44d998714bea0,
title = "Calibration of the calorimeter signal waveform in the SND detector",
abstract = "The new spectrometric channel for the Spherical Neutral Detector (SND) electromagnetic calorimeter (EMC) is described. It provides measurement of the calorimeter signal arrival time and amplitude with 1 ns and 250 keV resolutions, respectively. The new electronics is useful for reliable detection of low-speed anti-neutrons from the e +e −→n{\=n} reaction near threshold and needed for increasing the EMC operation rate. The algorithm of determination of signal parameters (time, amplitude) is based on invariability of the signal waveform. We present the procedure of the waveform calibration using signals from cosmic-muon and Bhabha scattering events. ",
keywords = "Calorimetry",
author = "Achasov, {M. N.} and Bogdanchikov, {A. G.} and Druzhinin, {V. P.} and Korol, {A. A.} and Koshuba, {S. V.} and Kovrizhin, {D. P.} and Surin, {I. K.} and Tekut'ev, {A. I.} and Usov, {Yu V.} and Zhulanov, {V. V.}",
year = "2019",
month = aug,
day = "21",
doi = "10.1016/j.nima.2018.10.038",
language = "English",
volume = "936",
pages = "117--118",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",

}

RIS

TY - JOUR

T1 - Calibration of the calorimeter signal waveform in the SND detector

AU - Achasov, M. N.

AU - Bogdanchikov, A. G.

AU - Druzhinin, V. P.

AU - Korol, A. A.

AU - Koshuba, S. V.

AU - Kovrizhin, D. P.

AU - Surin, I. K.

AU - Tekut'ev, A. I.

AU - Usov, Yu V.

AU - Zhulanov, V. V.

PY - 2019/8/21

Y1 - 2019/8/21

N2 - The new spectrometric channel for the Spherical Neutral Detector (SND) electromagnetic calorimeter (EMC) is described. It provides measurement of the calorimeter signal arrival time and amplitude with 1 ns and 250 keV resolutions, respectively. The new electronics is useful for reliable detection of low-speed anti-neutrons from the e +e −→nn̄ reaction near threshold and needed for increasing the EMC operation rate. The algorithm of determination of signal parameters (time, amplitude) is based on invariability of the signal waveform. We present the procedure of the waveform calibration using signals from cosmic-muon and Bhabha scattering events.

AB - The new spectrometric channel for the Spherical Neutral Detector (SND) electromagnetic calorimeter (EMC) is described. It provides measurement of the calorimeter signal arrival time and amplitude with 1 ns and 250 keV resolutions, respectively. The new electronics is useful for reliable detection of low-speed anti-neutrons from the e +e −→nn̄ reaction near threshold and needed for increasing the EMC operation rate. The algorithm of determination of signal parameters (time, amplitude) is based on invariability of the signal waveform. We present the procedure of the waveform calibration using signals from cosmic-muon and Bhabha scattering events.

KW - Calorimetry

UR - http://www.scopus.com/inward/record.url?scp=85055734807&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2018.10.038

DO - 10.1016/j.nima.2018.10.038

M3 - Review article

AN - SCOPUS:85055734807

VL - 936

SP - 117

EP - 118

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

ER -

ID: 17282372