Standard

Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector. / Aulchenko, V.; Bobrov, A.; Ferber, T. и др.

в: Journal of Instrumentation, Том 12, № 8, 08001, 01.08.2017.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Aulchenko, V, Bobrov, A, Ferber, T, Kuzmin, A, Miyabayshi, K, De Nardo, G, Shebalin, V, Sibidanov, A, Usov, Y & Zhulanov, V 2017, 'Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector', Journal of Instrumentation, Том. 12, № 8, 08001. https://doi.org/10.1088/1748-0221/12/08/C08001

APA

Aulchenko, V., Bobrov, A., Ferber, T., Kuzmin, A., Miyabayshi, K., De Nardo, G., Shebalin, V., Sibidanov, A., Usov, Y., & Zhulanov, V. (2017). Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector. Journal of Instrumentation, 12(8), [08001]. https://doi.org/10.1088/1748-0221/12/08/C08001

Vancouver

Aulchenko V, Bobrov A, Ferber T, Kuzmin A, Miyabayshi K, De Nardo G и др. Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector. Journal of Instrumentation. 2017 авг. 1;12(8):08001. doi: 10.1088/1748-0221/12/08/C08001

Author

Aulchenko, V. ; Bobrov, A. ; Ferber, T. и др. / Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector. в: Journal of Instrumentation. 2017 ; Том 12, № 8.

BibTeX

@article{7967573099a542f7abf1d281be2bc81c,
title = "Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector",
abstract = "The Belle-II electromagnetic calorimeter inherited crystals and front-end electronics from the Belle detector, however the readout electronics was essentially modified. New electronics provides continuous digitization of the shaped signal followed by the signal wave form analysis with the further reconstruction of both, amplitude and time of the signal. The time information allows one to suppress background essentially. The algorithm, which is implemented in FPGA, is properly simulated. We implemented this algorithm to the simulation software and studied it with the MC background data. The procedure for the calibration of the response function has been developed and tested with the barrel counters using cosmic-ray data.",
keywords = "Calorimeter methods, Digital signal processing (DSP), Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)",
author = "V. Aulchenko and A. Bobrov and T. Ferber and A. Kuzmin and K. Miyabayshi and {De Nardo}, G. and V. Shebalin and A. Sibidanov and Yu Usov and V. Zhulanov",
year = "2017",
month = aug,
day = "1",
doi = "10.1088/1748-0221/12/08/C08001",
language = "English",
volume = "12",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "8",

}

RIS

TY - JOUR

T1 - Time and energy reconstruction at the electromagnetic calorimeter of the Belle-II detector

AU - Aulchenko, V.

AU - Bobrov, A.

AU - Ferber, T.

AU - Kuzmin, A.

AU - Miyabayshi, K.

AU - De Nardo, G.

AU - Shebalin, V.

AU - Sibidanov, A.

AU - Usov, Yu

AU - Zhulanov, V.

PY - 2017/8/1

Y1 - 2017/8/1

N2 - The Belle-II electromagnetic calorimeter inherited crystals and front-end electronics from the Belle detector, however the readout electronics was essentially modified. New electronics provides continuous digitization of the shaped signal followed by the signal wave form analysis with the further reconstruction of both, amplitude and time of the signal. The time information allows one to suppress background essentially. The algorithm, which is implemented in FPGA, is properly simulated. We implemented this algorithm to the simulation software and studied it with the MC background data. The procedure for the calibration of the response function has been developed and tested with the barrel counters using cosmic-ray data.

AB - The Belle-II electromagnetic calorimeter inherited crystals and front-end electronics from the Belle detector, however the readout electronics was essentially modified. New electronics provides continuous digitization of the shaped signal followed by the signal wave form analysis with the further reconstruction of both, amplitude and time of the signal. The time information allows one to suppress background essentially. The algorithm, which is implemented in FPGA, is properly simulated. We implemented this algorithm to the simulation software and studied it with the MC background data. The procedure for the calibration of the response function has been developed and tested with the barrel counters using cosmic-ray data.

KW - Calorimeter methods

KW - Digital signal processing (DSP)

KW - Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)

UR - http://www.scopus.com/inward/record.url?scp=85031030138&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/12/08/C08001

DO - 10.1088/1748-0221/12/08/C08001

M3 - Article

AN - SCOPUS:85031030138

VL - 12

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 8

M1 - 08001

ER -

ID: 9895062