Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
The project of Kirkpatrick – Baez focusing system for beam diagnostics on the SKIF. / Meshkov, O. I.; Dorokhov, V. L.; Reshetov, D. F. и др.
Proceedings of the International Beam Instrumentation Conference, IBIC. ред. / Jianshe Cao; Junhui Yue; Lin Bian; Ivan Andrian; Volker RW Schaa; Zhichu Chen. Joint Accelerator Conferences Website (JACoW), 2024. стр. 262-265 (Proceedings of the International Beam Instrumentation Conference, IBIC).Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
}
TY - GEN
T1 - The project of Kirkpatrick – Baez focusing system for beam diagnostics on the SKIF
AU - Meshkov, O. I.
AU - Dorokhov, V. L.
AU - Reshetov, D. F.
AU - Glushkov, E.
AU - Malushev, I.
N1 - Conference code: 13
PY - 2024
Y1 - 2024
N2 - The Siberian Ring Radiation Source (SKIF) is an upcoming 4th-generation SR source under construction in Novosibirsk, Russia. The designed beam emittance for SKIF is 75 pm-rad, which corresponds to a beam size of 6 micrometers at the observation point within the dipole magnet. The transverse beam dimensions are essential parameters for tuning and reliable operation of the facility. The SKIF diagnostic suite includes a double-slit interferometer operating in the ultraviolet region of the spectrum. This device's spatial resolution should be sufficient to measure the radial size of the beam to an accuracy of 10 percent. These diagnostics will be used during the commissioning of SKIF and afterwards. Although an additional source of information on beam dimensions and dynamics would be desirable for assurance, taking into account the record designed value of beam emittance. The application of X-ray optics and the Kirkpatrick-Baez focusing system seem to be the most suitable option. The paper discusses the project of this system, which will acquire X-rays from a SKIF dipole magnet.
AB - The Siberian Ring Radiation Source (SKIF) is an upcoming 4th-generation SR source under construction in Novosibirsk, Russia. The designed beam emittance for SKIF is 75 pm-rad, which corresponds to a beam size of 6 micrometers at the observation point within the dipole magnet. The transverse beam dimensions are essential parameters for tuning and reliable operation of the facility. The SKIF diagnostic suite includes a double-slit interferometer operating in the ultraviolet region of the spectrum. This device's spatial resolution should be sufficient to measure the radial size of the beam to an accuracy of 10 percent. These diagnostics will be used during the commissioning of SKIF and afterwards. Although an additional source of information on beam dimensions and dynamics would be desirable for assurance, taking into account the record designed value of beam emittance. The application of X-ray optics and the Kirkpatrick-Baez focusing system seem to be the most suitable option. The paper discusses the project of this system, which will acquire X-rays from a SKIF dipole magnet.
UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85219756250&origin=inward&txGid=d2084cbbed73115637658878c3057f90
UR - https://www.mendeley.com/catalogue/1751583f-b9aa-35ea-8b2a-5beab51fb5f2/
U2 - 10.18429/JACoW-IBIC2024-WEP08
DO - 10.18429/JACoW-IBIC2024-WEP08
M3 - Conference contribution
T3 - Proceedings of the International Beam Instrumentation Conference, IBIC
SP - 262
EP - 265
BT - Proceedings of the International Beam Instrumentation Conference, IBIC
A2 - Cao, Jianshe
A2 - Yue, Junhui
A2 - Bian, Lin
A2 - Andrian, Ivan
A2 - Schaa, Volker RW
A2 - Chen, Zhichu
PB - Joint Accelerator Conferences Website (JACoW)
T2 - 13th International Beam Instrumentation Conference
Y2 - 9 September 2024 through 13 September 2024
ER -
ID: 65075263