Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
The Measuring System for the Thomson Scattering Diagnostics of the GOL-3 and GDT Facilities. / Puryga, E. A.; Khilchenko, A. D.; Kvashnin, A. N. и др.
в: Instruments and Experimental Techniques, Том 61, № 6, 01.11.2018, стр. 796-803.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - The Measuring System for the Thomson Scattering Diagnostics of the GOL-3 and GDT Facilities
AU - Puryga, E. A.
AU - Khilchenko, A. D.
AU - Kvashnin, A. N.
AU - Zubarev, P. V.
AU - Prikhodko, V. V.
AU - Ivanenko, S. V.
AU - Moiseev, D. V.
AU - Kasatov, A. A.
AU - Maksimov, V. V.
AU - Vyacheslavov, L. N.
N1 - Publisher Copyright: © 2018, Pleiades Publishing, Inc.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - The measuring system for Thomson scattering diagnostics of the GOL-3 and GDT facilities at the Budker Institute of Nuclear Physics is described. The system has a modular architecture and is based on eight-channel measuring subsystems, including photodetectors, two-channel recorders (ADC12500), synchronization modules, and the Ethernet/UART communication channel adapter. The photodetectors are based on avalanche photodiodes and are operable in the frequency range of 0–50 MHz. The ADC12500 recorders are used to measure scattering signals with a duration of ~20–30 ns at a sampling rate of to 500 MHz and an amplitude resolution of 12 bits and accumulate data in a buffer memory with a capacity as large as 2 MB.
AB - The measuring system for Thomson scattering diagnostics of the GOL-3 and GDT facilities at the Budker Institute of Nuclear Physics is described. The system has a modular architecture and is based on eight-channel measuring subsystems, including photodetectors, two-channel recorders (ADC12500), synchronization modules, and the Ethernet/UART communication channel adapter. The photodetectors are based on avalanche photodiodes and are operable in the frequency range of 0–50 MHz. The ADC12500 recorders are used to measure scattering signals with a duration of ~20–30 ns at a sampling rate of to 500 MHz and an amplitude resolution of 12 bits and accumulate data in a buffer memory with a capacity as large as 2 MB.
UR - http://www.scopus.com/inward/record.url?scp=85057630050&partnerID=8YFLogxK
U2 - 10.1134/S0020441218060118
DO - 10.1134/S0020441218060118
M3 - Article
AN - SCOPUS:85057630050
VL - 61
SP - 796
EP - 803
JO - Instruments and Experimental Techniques
JF - Instruments and Experimental Techniques
SN - 0020-4412
IS - 6
ER -
ID: 17687186