Standard

The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2. / Piterimova, M. V.; Kosinov, A. D.; Panina, A. V. и др.

в: Journal of Physics: Conference Series, Том 1404, № 1, 012094, 06.12.2019.

Результаты исследований: Научные публикации в периодических изданияхстатья по материалам конференцииРецензирование

Harvard

Piterimova, MV, Kosinov, AD, Panina, AV, Semionov, NV, Ermolaev, YG & Yatskikh, AA 2019, 'The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2', Journal of Physics: Conference Series, Том. 1404, № 1, 012094. https://doi.org/10.1088/1742-6596/1404/1/012094

APA

Vancouver

Piterimova MV, Kosinov AD, Panina AV, Semionov NV, Ermolaev YG, Yatskikh AA. The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2. Journal of Physics: Conference Series. 2019 дек. 6;1404(1):012094. doi: 10.1088/1742-6596/1404/1/012094

Author

Piterimova, M. V. ; Kosinov, A. D. ; Panina, A. V. и др. / The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2. в: Journal of Physics: Conference Series. 2019 ; Том 1404, № 1.

BibTeX

@article{5efb3b6af80d4c7485bbc9d196cf2799,
title = "The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2",
abstract = "Experimental data on the development of controlled disturbances in the boundary layer with a longitudinal vortex are analysed. It is found experimentally that the mean flow nonuniformity can vary from 0.7 to 0.9 V in terms of the CTA mean voltage or 30-40% in ρU. Such flow nonuniformity complicates the estimation of the wave spectra, where normalization on the mean voltage of the anemometer is required. The applicability of the standard processing procedure is investigated. Comparative analysis of the data shows that both normalization types considered in the work can be applicable. However, in the case of flow nonuniformity in the transverse direction, it is preferable to use the normalization on the median value over the mean voltage spanwise distribution.",
author = "Piterimova, {M. V.} and Kosinov, {A. D.} and Panina, {A. V.} and Semionov, {N. V.} and Ermolaev, {Yu G.} and Yatskikh, {A. A.}",
year = "2019",
month = dec,
day = "6",
doi = "10.1088/1742-6596/1404/1/012094",
language = "English",
volume = "1404",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",
note = "16th All-Russian Seminar with International Participation on Dynamics of Multiphase Media, DMM 2019 ; Conference date: 30-09-2019 Through 05-10-2019",

}

RIS

TY - JOUR

T1 - The controlled periodic impact on the longitudinal vortex in the boundary layer at Mach 2

AU - Piterimova, M. V.

AU - Kosinov, A. D.

AU - Panina, A. V.

AU - Semionov, N. V.

AU - Ermolaev, Yu G.

AU - Yatskikh, A. A.

PY - 2019/12/6

Y1 - 2019/12/6

N2 - Experimental data on the development of controlled disturbances in the boundary layer with a longitudinal vortex are analysed. It is found experimentally that the mean flow nonuniformity can vary from 0.7 to 0.9 V in terms of the CTA mean voltage or 30-40% in ρU. Such flow nonuniformity complicates the estimation of the wave spectra, where normalization on the mean voltage of the anemometer is required. The applicability of the standard processing procedure is investigated. Comparative analysis of the data shows that both normalization types considered in the work can be applicable. However, in the case of flow nonuniformity in the transverse direction, it is preferable to use the normalization on the median value over the mean voltage spanwise distribution.

AB - Experimental data on the development of controlled disturbances in the boundary layer with a longitudinal vortex are analysed. It is found experimentally that the mean flow nonuniformity can vary from 0.7 to 0.9 V in terms of the CTA mean voltage or 30-40% in ρU. Such flow nonuniformity complicates the estimation of the wave spectra, where normalization on the mean voltage of the anemometer is required. The applicability of the standard processing procedure is investigated. Comparative analysis of the data shows that both normalization types considered in the work can be applicable. However, in the case of flow nonuniformity in the transverse direction, it is preferable to use the normalization on the median value over the mean voltage spanwise distribution.

UR - http://www.scopus.com/inward/record.url?scp=85077816774&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/1404/1/012094

DO - 10.1088/1742-6596/1404/1/012094

M3 - Conference article

AN - SCOPUS:85077816774

VL - 1404

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012094

T2 - 16th All-Russian Seminar with International Participation on Dynamics of Multiphase Media, DMM 2019

Y2 - 30 September 2019 through 5 October 2019

ER -

ID: 23120381