Standard

Study of the influence of moderator material on sensitivity of the epithermal neutron flux detector using the 71Ga(n,γ)72Ga reaction. / Byambatseren, E.; Bykov, T.; Kasatov, D. и др.

в: Applied Radiation and Isotopes, Том 222, 111844, 01.08.2025.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Byambatseren E, Bykov T, Kasatov D, Kolesnikov I, Savinov S, Shein T и др. Study of the influence of moderator material on sensitivity of the epithermal neutron flux detector using the 71Ga(n,γ)72Ga reaction. Applied Radiation and Isotopes. 2025 авг. 1;222:111844. doi: 10.1016/j.apradiso.2025.111844

Author

BibTeX

@article{8e0c81e3054c41d18388faa916b04f25,
title = "Study of the influence of moderator material on sensitivity of the epithermal neutron flux detector using the 71Ga(n,γ)72Ga reaction",
abstract = "An intense epithermal neutron flux is necessary for boron neutron capture therapy (BNCT), a promising technique for the treatment of malignant tumors. The epithermal neutron flux is an essential characteristic of the BNCT neutron beam, and its measurement is directly related to the reliability of the treatment planning system. Such a tool could be a cylindrical activation detector using 71Ga (n,γ)72Ga reaction. In the detector, the activation material is positioned in the geometrical center of a cylinder moderator covered with cadmium foil. Two different teams of researchers calculated the sensitivities of detectors of the same size, but with different moderators which differ by a factor of 1.6. In this work, the effect of the moderator material on the sensitivity of the detector was experimentally studied.",
author = "E. Byambatseren and T. Bykov and D. Kasatov and Ia Kolesnikov and S. Savinov and T. Shein and S. Taskaev",
note = "The work was carried out within the framework of the state assignment of the Ministry of Science and Higher Education of the Russian Federation (No. 1024011000011-7-1.4.2; 3.5.2, FEEM-2024-0011). ",
year = "2025",
month = aug,
day = "1",
doi = "10.1016/j.apradiso.2025.111844",
language = "English",
volume = "222",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier Science Publishing Company, Inc.",

}

RIS

TY - JOUR

T1 - Study of the influence of moderator material on sensitivity of the epithermal neutron flux detector using the 71Ga(n,γ)72Ga reaction

AU - Byambatseren, E.

AU - Bykov, T.

AU - Kasatov, D.

AU - Kolesnikov, Ia

AU - Savinov, S.

AU - Shein, T.

AU - Taskaev, S.

N1 - The work was carried out within the framework of the state assignment of the Ministry of Science and Higher Education of the Russian Federation (No. 1024011000011-7-1.4.2; 3.5.2, FEEM-2024-0011).

PY - 2025/8/1

Y1 - 2025/8/1

N2 - An intense epithermal neutron flux is necessary for boron neutron capture therapy (BNCT), a promising technique for the treatment of malignant tumors. The epithermal neutron flux is an essential characteristic of the BNCT neutron beam, and its measurement is directly related to the reliability of the treatment planning system. Such a tool could be a cylindrical activation detector using 71Ga (n,γ)72Ga reaction. In the detector, the activation material is positioned in the geometrical center of a cylinder moderator covered with cadmium foil. Two different teams of researchers calculated the sensitivities of detectors of the same size, but with different moderators which differ by a factor of 1.6. In this work, the effect of the moderator material on the sensitivity of the detector was experimentally studied.

AB - An intense epithermal neutron flux is necessary for boron neutron capture therapy (BNCT), a promising technique for the treatment of malignant tumors. The epithermal neutron flux is an essential characteristic of the BNCT neutron beam, and its measurement is directly related to the reliability of the treatment planning system. Such a tool could be a cylindrical activation detector using 71Ga (n,γ)72Ga reaction. In the detector, the activation material is positioned in the geometrical center of a cylinder moderator covered with cadmium foil. Two different teams of researchers calculated the sensitivities of detectors of the same size, but with different moderators which differ by a factor of 1.6. In this work, the effect of the moderator material on the sensitivity of the detector was experimentally studied.

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-105003008272&origin=inward&txGid=16527558f9300ff9bce7752e20064698

U2 - 10.1016/j.apradiso.2025.111844

DO - 10.1016/j.apradiso.2025.111844

M3 - Article

VL - 222

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

M1 - 111844

ER -

ID: 65301688