Standard

Status and R&D of ASHIPH-SiPM option for PID. / Barnyakov, A. Y.; Bobrovnikov, V. S.; Buzykaev, A. R. и др.

в: International Journal of Modern Physics A, Том 39, № 26-27, 2442005, 30.09.2024.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Barnyakov, AY, Bobrovnikov, VS, Buzykaev, AR, Chepelev, AV, Danilyuk, AF, Efremov, RA, Katcin, AA, Kravchenko, EA, Kononov, SA, Kuyanov, IA, Ovtin, IV & Petrukhin, KG 2024, 'Status and R&D of ASHIPH-SiPM option for PID', International Journal of Modern Physics A, Том. 39, № 26-27, 2442005. https://doi.org/10.1142/S0217751X24420053

APA

Barnyakov, A. Y., Bobrovnikov, V. S., Buzykaev, A. R., Chepelev, A. V., Danilyuk, A. F., Efremov, R. A., Katcin, A. A., Kravchenko, E. A., Kononov, S. A., Kuyanov, I. A., Ovtin, I. V., & Petrukhin, K. G. (2024). Status and R&D of ASHIPH-SiPM option for PID. International Journal of Modern Physics A, 39(26-27), [2442005]. https://doi.org/10.1142/S0217751X24420053

Vancouver

Barnyakov AY, Bobrovnikov VS, Buzykaev AR, Chepelev AV, Danilyuk AF, Efremov RA и др. Status and R&D of ASHIPH-SiPM option for PID. International Journal of Modern Physics A. 2024 сент. 30;39(26-27):2442005. doi: 10.1142/S0217751X24420053

Author

Barnyakov, A. Y. ; Bobrovnikov, V. S. ; Buzykaev, A. R. и др. / Status and R&D of ASHIPH-SiPM option for PID. в: International Journal of Modern Physics A. 2024 ; Том 39, № 26-27.

BibTeX

@article{9330580b9491422bb435cfbebf855aab,
title = "Status and R&D of ASHIPH-SiPM option for PID",
abstract = "The ASHIPH (Aerogel, SHifter, PHotomultiplier) Cherenkov counters are considered as a particle identification system alternative option for the detector on future Super Charm-Tau factory. The ASHIPH counters have been operating successfully in the KEDR and SND experiments in Novosibirsk at the Budker Institute of Nuclear Physics. Previously in our experiments Micro Channel Plate PMTs were used for the photon detection in the ASHIPH counters. Now, we have developed a prototype of the ASHIPH counter with SiPM (Silicon PMTs) array as a photodetector. Such an upgrade will increase the number of detected photoelectrons by 2.5 times and consequently improve the quality of particle separation. The results of testing the ASHIPH counter prototype on the electron test beam facility of the VEPP-4M accelerator is presented.",
keywords = "ASHIPH, Aerogel, Particle identification, SiPM",
author = "Barnyakov, {A. Y.} and Bobrovnikov, {V. S.} and Buzykaev, {A. R.} and Chepelev, {A. V.} and Danilyuk, {A. F.} and Efremov, {R. A.} and Katcin, {A. A.} and Kravchenko, {E. A.} and Kononov, {S. A.} and Kuyanov, {I. A.} and Ovtin, {I. V.} and Petrukhin, {K. G.}",
year = "2024",
month = sep,
day = "30",
doi = "10.1142/S0217751X24420053",
language = "English",
volume = "39",
journal = "International Journal of Modern Physics A",
issn = "0217-751X",
publisher = "World Scientific Publishing Co. Pte Ltd",
number = "26-27",

}

RIS

TY - JOUR

T1 - Status and R&D of ASHIPH-SiPM option for PID

AU - Barnyakov, A. Y.

AU - Bobrovnikov, V. S.

AU - Buzykaev, A. R.

AU - Chepelev, A. V.

AU - Danilyuk, A. F.

AU - Efremov, R. A.

AU - Katcin, A. A.

AU - Kravchenko, E. A.

AU - Kononov, S. A.

AU - Kuyanov, I. A.

AU - Ovtin, I. V.

AU - Petrukhin, K. G.

PY - 2024/9/30

Y1 - 2024/9/30

N2 - The ASHIPH (Aerogel, SHifter, PHotomultiplier) Cherenkov counters are considered as a particle identification system alternative option for the detector on future Super Charm-Tau factory. The ASHIPH counters have been operating successfully in the KEDR and SND experiments in Novosibirsk at the Budker Institute of Nuclear Physics. Previously in our experiments Micro Channel Plate PMTs were used for the photon detection in the ASHIPH counters. Now, we have developed a prototype of the ASHIPH counter with SiPM (Silicon PMTs) array as a photodetector. Such an upgrade will increase the number of detected photoelectrons by 2.5 times and consequently improve the quality of particle separation. The results of testing the ASHIPH counter prototype on the electron test beam facility of the VEPP-4M accelerator is presented.

AB - The ASHIPH (Aerogel, SHifter, PHotomultiplier) Cherenkov counters are considered as a particle identification system alternative option for the detector on future Super Charm-Tau factory. The ASHIPH counters have been operating successfully in the KEDR and SND experiments in Novosibirsk at the Budker Institute of Nuclear Physics. Previously in our experiments Micro Channel Plate PMTs were used for the photon detection in the ASHIPH counters. Now, we have developed a prototype of the ASHIPH counter with SiPM (Silicon PMTs) array as a photodetector. Such an upgrade will increase the number of detected photoelectrons by 2.5 times and consequently improve the quality of particle separation. The results of testing the ASHIPH counter prototype on the electron test beam facility of the VEPP-4M accelerator is presented.

KW - ASHIPH

KW - Aerogel

KW - Particle identification

KW - SiPM

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85202880493&origin=inward&txGid=0e82f0795471a3bf59f047e05f4bcabb

UR - https://www.mendeley.com/catalogue/b75ed1e8-baee-3aef-b833-e033b409343c/

U2 - 10.1142/S0217751X24420053

DO - 10.1142/S0217751X24420053

M3 - Article

VL - 39

JO - International Journal of Modern Physics A

JF - International Journal of Modern Physics A

SN - 0217-751X

IS - 26-27

M1 - 2442005

ER -

ID: 61115496