Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Spatial resolution of the detectors based on Gas Electron Multipliers. / Kudryavtsev, V. N.; Maltsev, T. V.; Shekhtman, L. I.
в: Journal of Instrumentation, Том 15, № 5, C05018, 01.05.2020.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Spatial resolution of the detectors based on Gas Electron Multipliers
AU - Kudryavtsev, V. N.
AU - Maltsev, T. V.
AU - Shekhtman, L. I.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Coordinate detectors based on Gas Electron Multipliers (GEM) are used in experiments at many high energy physics centers and at Budker Institute of Nuclear Physics particularly. Spatial resolution of these detectors is known to be in tens microns scale. Also the detectors possess a rate capability up to 107 cm-2s-1. Consequently, the precise study of best possible coordinate resolution, achieved with GEM-detectors, is a significant task. The experimental data, collected by the moment, provides the possibility to compare it with the results of the simulation. The simulation of the detector performance includes transport of electrons through the detector medium, tracking of an avalanche evolution inside the working volume, as well as registering of the signal distribution on the readout strips. The simulation of individual detector shows that its spatial resolution is considerably better than the experimental results with the difference about two standard deviations. In order to find out possible reasons of the contradiction between measurements and the simulation of the individual detector, the simulation of complete experimental set-up (including tracking detectors) is performed. The results of complete set-up and individual detector simulations are determined to coincide in general.
AB - Coordinate detectors based on Gas Electron Multipliers (GEM) are used in experiments at many high energy physics centers and at Budker Institute of Nuclear Physics particularly. Spatial resolution of these detectors is known to be in tens microns scale. Also the detectors possess a rate capability up to 107 cm-2s-1. Consequently, the precise study of best possible coordinate resolution, achieved with GEM-detectors, is a significant task. The experimental data, collected by the moment, provides the possibility to compare it with the results of the simulation. The simulation of the detector performance includes transport of electrons through the detector medium, tracking of an avalanche evolution inside the working volume, as well as registering of the signal distribution on the readout strips. The simulation of individual detector shows that its spatial resolution is considerably better than the experimental results with the difference about two standard deviations. In order to find out possible reasons of the contradiction between measurements and the simulation of the individual detector, the simulation of complete experimental set-up (including tracking detectors) is performed. The results of complete set-up and individual detector simulations are determined to coincide in general.
KW - charge transport
KW - Detector modelling and simulations II (electric fields
KW - electron emission
KW - Electron multipliers (gas)
KW - etc)
KW - Gaseous detectors
KW - Gaseous imaging and tracking detectors
KW - multiplication and induction
KW - pulse formation
KW - Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc)
KW - GEM
UR - http://www.scopus.com/inward/record.url?scp=85085739490&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/15/05/C05018
DO - 10.1088/1748-0221/15/05/C05018
M3 - Article
AN - SCOPUS:85085739490
VL - 15
JO - Journal of Instrumentation
JF - Journal of Instrumentation
SN - 1748-0221
IS - 5
M1 - C05018
ER -
ID: 24411048