Standard

Performance of a Group II Intron Reverse Transcriptase from Anoxybacillus flavithermus in Duplex RT-LAMP for SARS-CoV-2 Detection. / Oscorbin, Igor P.; Baranova, Elizaveta D.; Filipenko, Maxim L.

в: ACS Infectious Diseases, Том 12, № 10, 2026, стр. 3351-3361.

Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование

Harvard

APA

Vancouver

Oscorbin IP, Baranova ED, Filipenko ML. Performance of a Group II Intron Reverse Transcriptase from Anoxybacillus flavithermus in Duplex RT-LAMP for SARS-CoV-2 Detection. ACS Infectious Diseases. 2026;12(10):3351-3361. doi: 10.1021/acsinfecdis.6c00293

Author

Oscorbin, Igor P. ; Baranova, Elizaveta D. ; Filipenko, Maxim L. / Performance of a Group II Intron Reverse Transcriptase from Anoxybacillus flavithermus in Duplex RT-LAMP for SARS-CoV-2 Detection. в: ACS Infectious Diseases. 2026 ; Том 12, № 10. стр. 3351-3361.

BibTeX

@article{65059b9d0991473bb1def6018e61a758,
title = "Performance of a Group II Intron Reverse Transcriptase from Anoxybacillus flavithermus in Duplex RT-LAMP for SARS-CoV-2 Detection",
abstract = "Reverse transcriptases from bacterial group II introns (GII RTs) demonstrate superior thermostability and processivity compared with retroviral counterparts. While GII RTs have proven advantageous for RNA-seq, their performance in other applications, such as reverse transcription loop-mediated isothermal amplification (RT-LAMP), remains poorly studied. RT-LAMP is a widely used method suitable for point-of-care diagnostics of RNA viruses and other pathogens. In this study, we compared the performance in RT-LAMP of GII RT from the thermophilic bacterium Anoxybacillus flavithermus (Afl RT) with that of the retroviral RNase H-deficient reverse transcriptase M-MuLV. A duplex RT-LAMP targeting SARS-CoV-2 and MS2 phage genomic RNA (internal control) served as a model. Preheating at 95 °C and 1.5 M betaine increased the efficiency of RT-LAMP with both reverse transcriptases. Under these conditions, the optimal temperature range and time of reverse transcription were similar for both enzymes, 55–60 °C and 15 min, respectively. However, high concentrations of Afl RT (>50 U/reaction) inhibited RT-LAMP. Notably, RT-LAMP with Afl RT demonstrated higher sensitivity for detecting both in vitro-transcribed RNA fragments and SARS-CoV-2–positive samples. In validation against RT-qPCR using nasal swabs (200 SARS-CoV-2-positive and 200 negative samples) from patients with respiratory symptoms, the observed sensitivity of RT-LAMP with Afl RT was 100% (200/200; 95% CI, 98.17–100%), whereas with M-MuLV RT, sensitivity was 97.0% (194/200; 95% CI, 93.58–98.89%). Specificity was 100% for both RTs (200/200; 95% CI, 98.17–100%). These observations demonstrate that Afl RT is suitable for RT-LAMP and may increase the sensitivity of LAMP-based diagnostics.",
keywords = "Afl RT, Anoxybacillus flavithermus, LAMP, M-MuLV RT, SARS-CoV-2, reverse transcriptase",
author = "Oscorbin, {Igor P.} and Baranova, {Elizaveta D.} and Filipenko, {Maxim L.}",
year = "2026",
doi = "10.1021/acsinfecdis.6c00293",
language = "English",
volume = "12",
pages = "3351--3361",
journal = "ACS Infectious Diseases",
issn = "2373-8227",
number = "10",

}

RIS

TY - JOUR

T1 - Performance of a Group II Intron Reverse Transcriptase from Anoxybacillus flavithermus in Duplex RT-LAMP for SARS-CoV-2 Detection

AU - Oscorbin, Igor P.

AU - Baranova, Elizaveta D.

AU - Filipenko, Maxim L.

PY - 2026

Y1 - 2026

N2 - Reverse transcriptases from bacterial group II introns (GII RTs) demonstrate superior thermostability and processivity compared with retroviral counterparts. While GII RTs have proven advantageous for RNA-seq, their performance in other applications, such as reverse transcription loop-mediated isothermal amplification (RT-LAMP), remains poorly studied. RT-LAMP is a widely used method suitable for point-of-care diagnostics of RNA viruses and other pathogens. In this study, we compared the performance in RT-LAMP of GII RT from the thermophilic bacterium Anoxybacillus flavithermus (Afl RT) with that of the retroviral RNase H-deficient reverse transcriptase M-MuLV. A duplex RT-LAMP targeting SARS-CoV-2 and MS2 phage genomic RNA (internal control) served as a model. Preheating at 95 °C and 1.5 M betaine increased the efficiency of RT-LAMP with both reverse transcriptases. Under these conditions, the optimal temperature range and time of reverse transcription were similar for both enzymes, 55–60 °C and 15 min, respectively. However, high concentrations of Afl RT (>50 U/reaction) inhibited RT-LAMP. Notably, RT-LAMP with Afl RT demonstrated higher sensitivity for detecting both in vitro-transcribed RNA fragments and SARS-CoV-2–positive samples. In validation against RT-qPCR using nasal swabs (200 SARS-CoV-2-positive and 200 negative samples) from patients with respiratory symptoms, the observed sensitivity of RT-LAMP with Afl RT was 100% (200/200; 95% CI, 98.17–100%), whereas with M-MuLV RT, sensitivity was 97.0% (194/200; 95% CI, 93.58–98.89%). Specificity was 100% for both RTs (200/200; 95% CI, 98.17–100%). These observations demonstrate that Afl RT is suitable for RT-LAMP and may increase the sensitivity of LAMP-based diagnostics.

AB - Reverse transcriptases from bacterial group II introns (GII RTs) demonstrate superior thermostability and processivity compared with retroviral counterparts. While GII RTs have proven advantageous for RNA-seq, their performance in other applications, such as reverse transcription loop-mediated isothermal amplification (RT-LAMP), remains poorly studied. RT-LAMP is a widely used method suitable for point-of-care diagnostics of RNA viruses and other pathogens. In this study, we compared the performance in RT-LAMP of GII RT from the thermophilic bacterium Anoxybacillus flavithermus (Afl RT) with that of the retroviral RNase H-deficient reverse transcriptase M-MuLV. A duplex RT-LAMP targeting SARS-CoV-2 and MS2 phage genomic RNA (internal control) served as a model. Preheating at 95 °C and 1.5 M betaine increased the efficiency of RT-LAMP with both reverse transcriptases. Under these conditions, the optimal temperature range and time of reverse transcription were similar for both enzymes, 55–60 °C and 15 min, respectively. However, high concentrations of Afl RT (>50 U/reaction) inhibited RT-LAMP. Notably, RT-LAMP with Afl RT demonstrated higher sensitivity for detecting both in vitro-transcribed RNA fragments and SARS-CoV-2–positive samples. In validation against RT-qPCR using nasal swabs (200 SARS-CoV-2-positive and 200 negative samples) from patients with respiratory symptoms, the observed sensitivity of RT-LAMP with Afl RT was 100% (200/200; 95% CI, 98.17–100%), whereas with M-MuLV RT, sensitivity was 97.0% (194/200; 95% CI, 93.58–98.89%). Specificity was 100% for both RTs (200/200; 95% CI, 98.17–100%). These observations demonstrate that Afl RT is suitable for RT-LAMP and may increase the sensitivity of LAMP-based diagnostics.

KW - Afl RT

KW - Anoxybacillus flavithermus

KW - LAMP

KW - M-MuLV RT

KW - SARS-CoV-2

KW - reverse transcriptase

UR - https://www.scopus.com/pages/publications/105052795134

UR - https://www.mendeley.com/catalogue/04f626c6-476e-3c08-b2d1-7f95913adb92/

U2 - 10.1021/acsinfecdis.6c00293

DO - 10.1021/acsinfecdis.6c00293

M3 - Article

C2 - 42917122

VL - 12

SP - 3351

EP - 3361

JO - ACS Infectious Diseases

JF - ACS Infectious Diseases

SN - 2373-8227

IS - 10

ER -

ID: 85048129