Standard

New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. / Zhabin, V. N.; Achasov, M. N.; Bogdanchikov, A. G. и др.

в: Instruments and Experimental Techniques, Том 68, № 5, 10.2025, стр. 695-706.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Zhabin, VN, Achasov, MN, Bogdanchikov, AG, Botov, AA, Druzhinin, VP, Zhulanov, VV, Korol, AA, Kryukov, AP, Obrazovskiy, AE, Pugachev, KV, Tekutiev, AI, Usov, YV & Kharlamov, AG 2025, 'New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000', Instruments and Experimental Techniques, Том. 68, № 5, стр. 695-706. https://doi.org/10.1134/S0020441225701088

APA

Zhabin, V. N., Achasov, M. N., Bogdanchikov, A. G., Botov, A. A., Druzhinin, V. P., Zhulanov, V. V., Korol, A. A., Kryukov, A. P., Obrazovskiy, A. E., Pugachev, K. V., Tekutiev, A. I., Usov, Y. V., & Kharlamov, A. G. (2025). New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. Instruments and Experimental Techniques, 68(5), 695-706. https://doi.org/10.1134/S0020441225701088

Vancouver

Zhabin VN, Achasov MN, Bogdanchikov AG, Botov AA, Druzhinin VP, Zhulanov VV и др. New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. Instruments and Experimental Techniques. 2025 окт.;68(5):695-706. doi: 10.1134/S0020441225701088

Author

Zhabin, V. N. ; Achasov, M. N. ; Bogdanchikov, A. G. и др. / New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. в: Instruments and Experimental Techniques. 2025 ; Том 68, № 5. стр. 695-706.

BibTeX

@article{c14bb145af7d4dcf829ab39c4bc5930c,
title = "New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000",
abstract = "New electronics was developed and mounted in 2022 to digitize signals from the tracking system of the Spherical Neutral Detector at the VEPP-2000 collider of the Budker Institute of Nuclear Physics. It is based on flash analog-to-digital converters and field programmable gate arrays and is used for digitization at a signal sampling rate of about 200 MHz with a resolution of 12 bits. Data are transmitted from each board to the data acquisition system via Ethernet with the bandwidth of 1 Gbit/s. Thanks to this, the new electronics is significantly better than the previous version in terms of the maximum event recording rate, and events can be recorded at a rate as high as 1.5 kHz. A special algorithm for extracting the amplitudes and response times from oscillograms has been developed. Data acquisition has been carried out with the new electronics since 2023. The resolution measured for the parameters of reconstructed tracks meets the requirements of 0.82° for the polar angle and 0.38° for the azimuthal angle.",
author = "Zhabin, {V. N.} and Achasov, {M. N.} and Bogdanchikov, {A. G.} and Botov, {A. A.} and Druzhinin, {V. P.} and Zhulanov, {V. V.} and Korol, {A. A.} and Kryukov, {A. P.} and Obrazovskiy, {A. E.} and Pugachev, {K. V.} and Tekutiev, {A. I.} and Usov, {Yu V.} and Kharlamov, {A. G.}",
note = "Zhabin, V.N., Achasov, M.N., Bogdanchikov, A.G. et al. New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. Instrum Exp Tech 68, 695–706 (2025). https://doi.org/10.1134/S0020441225701088.",
year = "2025",
month = oct,
doi = "10.1134/S0020441225701088",
language = "English",
volume = "68",
pages = "695--706",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "5",

}

RIS

TY - JOUR

T1 - New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000

AU - Zhabin, V. N.

AU - Achasov, M. N.

AU - Bogdanchikov, A. G.

AU - Botov, A. A.

AU - Druzhinin, V. P.

AU - Zhulanov, V. V.

AU - Korol, A. A.

AU - Kryukov, A. P.

AU - Obrazovskiy, A. E.

AU - Pugachev, K. V.

AU - Tekutiev, A. I.

AU - Usov, Yu V.

AU - Kharlamov, A. G.

N1 - Zhabin, V.N., Achasov, M.N., Bogdanchikov, A.G. et al. New Electronics for the Tracking System of the Spherical Neutral Detector at VEPP-2000. Instrum Exp Tech 68, 695–706 (2025). https://doi.org/10.1134/S0020441225701088.

PY - 2025/10

Y1 - 2025/10

N2 - New electronics was developed and mounted in 2022 to digitize signals from the tracking system of the Spherical Neutral Detector at the VEPP-2000 collider of the Budker Institute of Nuclear Physics. It is based on flash analog-to-digital converters and field programmable gate arrays and is used for digitization at a signal sampling rate of about 200 MHz with a resolution of 12 bits. Data are transmitted from each board to the data acquisition system via Ethernet with the bandwidth of 1 Gbit/s. Thanks to this, the new electronics is significantly better than the previous version in terms of the maximum event recording rate, and events can be recorded at a rate as high as 1.5 kHz. A special algorithm for extracting the amplitudes and response times from oscillograms has been developed. Data acquisition has been carried out with the new electronics since 2023. The resolution measured for the parameters of reconstructed tracks meets the requirements of 0.82° for the polar angle and 0.38° for the azimuthal angle.

AB - New electronics was developed and mounted in 2022 to digitize signals from the tracking system of the Spherical Neutral Detector at the VEPP-2000 collider of the Budker Institute of Nuclear Physics. It is based on flash analog-to-digital converters and field programmable gate arrays and is used for digitization at a signal sampling rate of about 200 MHz with a resolution of 12 bits. Data are transmitted from each board to the data acquisition system via Ethernet with the bandwidth of 1 Gbit/s. Thanks to this, the new electronics is significantly better than the previous version in terms of the maximum event recording rate, and events can be recorded at a rate as high as 1.5 kHz. A special algorithm for extracting the amplitudes and response times from oscillograms has been developed. Data acquisition has been carried out with the new electronics since 2023. The resolution measured for the parameters of reconstructed tracks meets the requirements of 0.82° for the polar angle and 0.38° for the azimuthal angle.

UR - https://www.scopus.com/pages/publications/105029357667

UR - https://elibrary.ru/item.asp?id=88796980

UR - https://www.mendeley.com/catalogue/a80bce39-8665-3a7f-b809-1e43a0ec4437/

U2 - 10.1134/S0020441225701088

DO - 10.1134/S0020441225701088

M3 - Article

VL - 68

SP - 695

EP - 706

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 5

ER -

ID: 74605170