New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons. / Arzhannikov, A. V.; Makarov, M. A.; Samtsov, D. A. и др.

в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 942, 162349, 21.10.2019.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Arzhannikov, AV, Makarov, MA, Samtsov, DA, Sinitsky, SL & Stepanov, VD 2019, 'New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 942, 162349. https://doi.org/10.1016/j.nima.2019.162349

APA

Arzhannikov, A. V., Makarov, M. A., Samtsov, D. A., Sinitsky, S. L., & Stepanov, V. D. (2019). New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 942, [162349]. https://doi.org/10.1016/j.nima.2019.162349

Vancouver

Arzhannikov AV, Makarov MA, Samtsov DA, Sinitsky SL, Stepanov VD. New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 окт. 21;942:162349. doi: 10.1016/j.nima.2019.162349

Author

Arzhannikov, A. V. ; Makarov, M. A. ; Samtsov, D. A. и др. / New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 ; Том 942.

BibTeX

@article{f6ca2e764d5545b6b598a7f377545edc,
title = "New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons",
abstract = "Based on the regularities of the electron absorption in the ring collectors a new method for reconstructing the angular distribution function of the magnetized electrons has been worked out. To realize it the angular spread detector with a cylindrical channel of a variable cross-section was developed and applied in an experiment with a high-current electron beam. The results of the measurements with this detector have demonstrated the possibility to achieve an angular spread of 0.1 rad level in microsecond high-current beams generated in a magnetically insulated diode with an explosive-emission cathode at a voltage of ∼1 MV.",
keywords = "Angular spread detector, Distribution function of magnetized electrons, Electron beam",
author = "Arzhannikov, {A. V.} and Makarov, {M. A.} and Samtsov, {D. A.} and Sinitsky, {S. L.} and Stepanov, {V. D.}",
year = "2019",
month = oct,
day = "21",
doi = "10.1016/j.nima.2019.162349",
language = "English",
volume = "942",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",

}

RIS

TY - JOUR

T1 - New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons

AU - Arzhannikov, A. V.

AU - Makarov, M. A.

AU - Samtsov, D. A.

AU - Sinitsky, S. L.

AU - Stepanov, V. D.

PY - 2019/10/21

Y1 - 2019/10/21

N2 - Based on the regularities of the electron absorption in the ring collectors a new method for reconstructing the angular distribution function of the magnetized electrons has been worked out. To realize it the angular spread detector with a cylindrical channel of a variable cross-section was developed and applied in an experiment with a high-current electron beam. The results of the measurements with this detector have demonstrated the possibility to achieve an angular spread of 0.1 rad level in microsecond high-current beams generated in a magnetically insulated diode with an explosive-emission cathode at a voltage of ∼1 MV.

AB - Based on the regularities of the electron absorption in the ring collectors a new method for reconstructing the angular distribution function of the magnetized electrons has been worked out. To realize it the angular spread detector with a cylindrical channel of a variable cross-section was developed and applied in an experiment with a high-current electron beam. The results of the measurements with this detector have demonstrated the possibility to achieve an angular spread of 0.1 rad level in microsecond high-current beams generated in a magnetically insulated diode with an explosive-emission cathode at a voltage of ∼1 MV.

KW - Angular spread detector

KW - Distribution function of magnetized electrons

KW - Electron beam

UR - http://www.scopus.com/inward/record.url?scp=85069597250&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2019.162349

DO - 10.1016/j.nima.2019.162349

M3 - Article

AN - SCOPUS:85069597250

VL - 942

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

M1 - 162349

ER -

ID: 21044880