Standard

Measuring the Radiation Energy Density of a Pulsed X-Ray Source. / Akhmetshin, R. R.; Babichev, E. A.; Grigoriev, D. N. и др.

в: Instruments and Experimental Techniques, Том 62, № 2, 01.04.2019, стр. 232-235.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Akhmetshin, RR, Babichev, EA, Grigoriev, DN, Groshev, VR, Kazanin, VF, Komarskiy, AA, Korzhenevskiy, SR, Romakhin, AS, Serednyakov, SI, Stavrietskiy, GV, Talyshev, AA, Timofeev, AV, Shtol, DA & Chepusov, AS 2019, 'Measuring the Radiation Energy Density of a Pulsed X-Ray Source', Instruments and Experimental Techniques, Том. 62, № 2, стр. 232-235. https://doi.org/10.1134/S0020441219020015

APA

Akhmetshin, R. R., Babichev, E. A., Grigoriev, D. N., Groshev, V. R., Kazanin, V. F., Komarskiy, A. A., Korzhenevskiy, S. R., Romakhin, A. S., Serednyakov, S. I., Stavrietskiy, G. V., Talyshev, A. A., Timofeev, A. V., Shtol, D. A., & Chepusov, A. S. (2019). Measuring the Radiation Energy Density of a Pulsed X-Ray Source. Instruments and Experimental Techniques, 62(2), 232-235. https://doi.org/10.1134/S0020441219020015

Vancouver

Akhmetshin RR, Babichev EA, Grigoriev DN, Groshev VR, Kazanin VF, Komarskiy AA и др. Measuring the Radiation Energy Density of a Pulsed X-Ray Source. Instruments and Experimental Techniques. 2019 апр. 1;62(2):232-235. doi: 10.1134/S0020441219020015

Author

Akhmetshin, R. R. ; Babichev, E. A. ; Grigoriev, D. N. и др. / Measuring the Radiation Energy Density of a Pulsed X-Ray Source. в: Instruments and Experimental Techniques. 2019 ; Том 62, № 2. стр. 232-235.

BibTeX

@article{b8ea8271f79e45ddaac42c54978ba49f,
title = "Measuring the Radiation Energy Density of a Pulsed X-Ray Source",
abstract = "A method is presented for measuring the energy density of X-ray pulses with a duration of approximately 200 ns from a source with an energy of 2–3 J in its discharge circuit. A bismuth germanate (BGO) scintillator crystal is used for measurements. The absolute calibration of the energy scale has been carried out by measuring the amplitude spectrum of cosmic muons. The energy flux of an X-ray pulse, measured at a distance of 1 m from the anode of the source, is 20 GeV/cm 2 . ",
author = "Akhmetshin, {R. R.} and Babichev, {E. A.} and Grigoriev, {D. N.} and Groshev, {V. R.} and Kazanin, {V. F.} and Komarskiy, {A. A.} and Korzhenevskiy, {S. R.} and Romakhin, {A. S.} and Serednyakov, {S. I.} and Stavrietskiy, {G. V.} and Talyshev, {A. A.} and Timofeev, {A. V.} and Shtol, {D. A.} and Chepusov, {A. S.}",
year = "2019",
month = apr,
day = "1",
doi = "10.1134/S0020441219020015",
language = "English",
volume = "62",
pages = "232--235",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "2",

}

RIS

TY - JOUR

T1 - Measuring the Radiation Energy Density of a Pulsed X-Ray Source

AU - Akhmetshin, R. R.

AU - Babichev, E. A.

AU - Grigoriev, D. N.

AU - Groshev, V. R.

AU - Kazanin, V. F.

AU - Komarskiy, A. A.

AU - Korzhenevskiy, S. R.

AU - Romakhin, A. S.

AU - Serednyakov, S. I.

AU - Stavrietskiy, G. V.

AU - Talyshev, A. A.

AU - Timofeev, A. V.

AU - Shtol, D. A.

AU - Chepusov, A. S.

PY - 2019/4/1

Y1 - 2019/4/1

N2 - A method is presented for measuring the energy density of X-ray pulses with a duration of approximately 200 ns from a source with an energy of 2–3 J in its discharge circuit. A bismuth germanate (BGO) scintillator crystal is used for measurements. The absolute calibration of the energy scale has been carried out by measuring the amplitude spectrum of cosmic muons. The energy flux of an X-ray pulse, measured at a distance of 1 m from the anode of the source, is 20 GeV/cm 2 .

AB - A method is presented for measuring the energy density of X-ray pulses with a duration of approximately 200 ns from a source with an energy of 2–3 J in its discharge circuit. A bismuth germanate (BGO) scintillator crystal is used for measurements. The absolute calibration of the energy scale has been carried out by measuring the amplitude spectrum of cosmic muons. The energy flux of an X-ray pulse, measured at a distance of 1 m from the anode of the source, is 20 GeV/cm 2 .

UR - http://www.scopus.com/inward/record.url?scp=85065417842&partnerID=8YFLogxK

U2 - 10.1134/S0020441219020015

DO - 10.1134/S0020441219020015

M3 - Article

AN - SCOPUS:85065417842

VL - 62

SP - 232

EP - 235

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 2

ER -

ID: 20043182