Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Measuring the Current of a Beam of Argon Ions Accompanying a Beam of Protons in a Tandem Accelerator with Vacuum Insulation. / Kolesnikov, Ya A.; Ostreinov, G. M.; Ponomarev, P. D. и др.
в: Instruments and Experimental Techniques, Том 64, № 4, 07.2021, стр. 503-507.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Measuring the Current of a Beam of Argon Ions Accompanying a Beam of Protons in a Tandem Accelerator with Vacuum Insulation
AU - Kolesnikov, Ya A.
AU - Ostreinov, G. M.
AU - Ponomarev, P. D.
AU - Savinov, S. S.
AU - Taskaev, S. Yu
AU - Shchudlo, I. M.
N1 - Funding Information: This study was carried out with the financial support of the Russian Foundation for Basic Research within the framework of the scientific project no. 19-32-90118. Publisher Copyright: © 2021, Pleiades Publishing, Ltd. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2021/7
Y1 - 2021/7
N2 - In electrostatic tandem charged particle accelerators, gas stripping targets are used to convert negative ions into positive ones. Partial ionization of the gas by ions leads to the formation of an undesirable beam of stripping gas ions in the accelerating channels. In this work, the current of a beam of argon ions produced in a tandem accelerator with vacuum insulation was measured by mass spectroscopy. It is shown that the current of argon ions is 2000 times smaller than the current of the proton beam. The reliability of the measurements is provided by visualization of an argon ion beam on the surface of a lithium target and is also confirmed by an experiment with increased gas injection and an estimate of the possible contribution of the proton beam. It is shown that such a small value of the argon ion current does not pose a danger either as a source of additional heating of a lithium target, or as an additional load of a high-voltage power supply, and therefore does not require the previously proposed means for its suppression.
AB - In electrostatic tandem charged particle accelerators, gas stripping targets are used to convert negative ions into positive ones. Partial ionization of the gas by ions leads to the formation of an undesirable beam of stripping gas ions in the accelerating channels. In this work, the current of a beam of argon ions produced in a tandem accelerator with vacuum insulation was measured by mass spectroscopy. It is shown that the current of argon ions is 2000 times smaller than the current of the proton beam. The reliability of the measurements is provided by visualization of an argon ion beam on the surface of a lithium target and is also confirmed by an experiment with increased gas injection and an estimate of the possible contribution of the proton beam. It is shown that such a small value of the argon ion current does not pose a danger either as a source of additional heating of a lithium target, or as an additional load of a high-voltage power supply, and therefore does not require the previously proposed means for its suppression.
UR - http://www.scopus.com/inward/record.url?scp=85111402159&partnerID=8YFLogxK
U2 - 10.1134/S0020441221040199
DO - 10.1134/S0020441221040199
M3 - Article
AN - SCOPUS:85111402159
VL - 64
SP - 503
EP - 507
JO - Instruments and Experimental Techniques
JF - Instruments and Experimental Techniques
SN - 0020-4412
IS - 4
ER -