Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Measuring Proton Beam Parameters Using Boron-Enriched Plastic Scintillators. / Bykov, T. A.; Verkhovod, G. D.; Porosev, V. V. и др.
в: Instruments and Experimental Techniques, Том 69, № 1, 19.05.2026, стр. 160-165.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Measuring Proton Beam Parameters Using Boron-Enriched Plastic Scintillators
AU - Bykov, T. A.
AU - Verkhovod, G. D.
AU - Porosev, V. V.
AU - Taskaev, S. Yu
AU - Shemyakov, A. E.
N1 - Measuring Proton Beam Parameters Using Boron-Enriched Plastic Scintillators / T. A. Bykov, G. D. Verkhovod, V. V. Porosev [et al.] // Instruments and Experimental Techniques. – 2026. – Vol. 69, No. 1. – P. 160-165. – DOI 10.1134/S0020441226700089. – EDN ZUXDFY. The study was supported by the Russian Science Foundation (grant no. 19-72-30005, https://rscf.ru/project/19-72-30005/). Proton irradiation was carried out at the Collective Use Center based at the Prometheus proton therapy complex of the Physicotechnical Center (Lebedev Physical Institute, Russian Academy of Sciences) in Protvino.
PY - 2026/5/19
Y1 - 2026/5/19
N2 - The presented work reports the results of measuring the spatial distribution of proton and secondary particle fluxes at the Prometheus proton therapy facility of the Physico-technical Center, Lebedev Physical Institute, and gives a comparison with simulation results obtained using the Geant4 software package. Measurements conducted with a water phantom, as well as with a compact neutron detector based on a boron-enriched scintillator developed at the Budker Institute of Nuclear Physics, demonstrated good agreement between the observed neutron fluxes and the simulations. The simulation data suggest that the mechanism of enhanced biological effectiveness observed in several studies during proton irradiation with the use of boron-containing compounds is questionable, given the significantly lower contribution to the radiation dose from alpha particles compared to the dominant component caused by protons and other reaction products.
AB - The presented work reports the results of measuring the spatial distribution of proton and secondary particle fluxes at the Prometheus proton therapy facility of the Physico-technical Center, Lebedev Physical Institute, and gives a comparison with simulation results obtained using the Geant4 software package. Measurements conducted with a water phantom, as well as with a compact neutron detector based on a boron-enriched scintillator developed at the Budker Institute of Nuclear Physics, demonstrated good agreement between the observed neutron fluxes and the simulations. The simulation data suggest that the mechanism of enhanced biological effectiveness observed in several studies during proton irradiation with the use of boron-containing compounds is questionable, given the significantly lower contribution to the radiation dose from alpha particles compared to the dominant component caused by protons and other reaction products.
KW - devices for biology and medicine
KW - neutron detectors
KW - нейтронные детекторы
KW - устройства для биологии и медицины
UR - https://www.mendeley.com/catalogue/6265db2b-b644-3cb9-aa1b-779196539db1/
UR - https://www.scopus.com/pages/publications/105039617281
UR - https://elibrary.ru/item.asp?id=90790113
U2 - 10.1134/S0020441226700089
DO - 10.1134/S0020441226700089
M3 - Article
VL - 69
SP - 160
EP - 165
JO - Instruments and Experimental Techniques
JF - Instruments and Experimental Techniques
SN - 0020-4412
IS - 1
ER -
ID: 85422238