Standard

Measurement of the ripple of magnet power supply and its effect to the beam energy. / Zhang, Jian Yong; Cai, Xiao; Mo, Xiao Hu и др.

в: Radiation Detection Technology and Methods, Том 1, № 1, 7, 01.06.2017.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Zhang, JY, Cai, X, Mo, XH, Tang, GY, Wei, SJ, Long, FL, Chen, B, Achasov, MN & Muchnoi, NY 2017, 'Measurement of the ripple of magnet power supply and its effect to the beam energy', Radiation Detection Technology and Methods, Том. 1, № 1, 7. https://doi.org/10.1007/s41605-017-0008-0

APA

Zhang, J. Y., Cai, X., Mo, X. H., Tang, G. Y., Wei, S. J., Long, F. L., Chen, B., Achasov, M. N., & Muchnoi, N. Y. (2017). Measurement of the ripple of magnet power supply and its effect to the beam energy. Radiation Detection Technology and Methods, 1(1), [7]. https://doi.org/10.1007/s41605-017-0008-0

Vancouver

Zhang JY, Cai X, Mo XH, Tang GY, Wei SJ, Long FL и др. Measurement of the ripple of magnet power supply and its effect to the beam energy. Radiation Detection Technology and Methods. 2017 июнь 1;1(1):7. doi: 10.1007/s41605-017-0008-0

Author

Zhang, Jian Yong ; Cai, Xiao ; Mo, Xiao Hu и др. / Measurement of the ripple of magnet power supply and its effect to the beam energy. в: Radiation Detection Technology and Methods. 2017 ; Том 1, № 1.

BibTeX

@article{0dec3c1499784cee9cde8ee6cc5328d6,
title = "Measurement of the ripple of magnet power supply and its effect to the beam energy",
abstract = "Objective:: This study is aimed at measuring the ripple of magnetic power supply of BEPCII and checking its effect to beam energy. Materials and methods:: A sensor made of printed circuit board coils is designed and manufactured. The sensor was inserted into a good area region of the magnetic field with the surface perpendicular to the field force lines. The change of the magnetic field would be detected according to Faraday{\textquoteright}s law. Results:: The experiment result indicates that the time-dependent ripple of the magnetic field is in the magnitude of ppm. Conclusion:: Such a small effect of the time-dependent ripplecan be negligibleto beam energy.",
keywords = "29.00.00, 29.30.Kv, 78.40.Fy, Beam energy measurement, HPGe detector, Laser, MEASUREMENT SYSTEM",
author = "Zhang, {Jian Yong} and Xiao Cai and Mo, {Xiao Hu} and Tang, {Guang Yi} and Wei, {Shu Jun} and Long, {Feng Li} and Bin Chen and Achasov, {M. N.} and Muchnoi, {N. Yu}",
year = "2017",
month = jun,
day = "1",
doi = "10.1007/s41605-017-0008-0",
language = "English",
volume = "1",
journal = "Radiation Detection Technology and Methods",
issn = "2509-9930",
publisher = "Springer Singapore",
number = "1",

}

RIS

TY - JOUR

T1 - Measurement of the ripple of magnet power supply and its effect to the beam energy

AU - Zhang, Jian Yong

AU - Cai, Xiao

AU - Mo, Xiao Hu

AU - Tang, Guang Yi

AU - Wei, Shu Jun

AU - Long, Feng Li

AU - Chen, Bin

AU - Achasov, M. N.

AU - Muchnoi, N. Yu

PY - 2017/6/1

Y1 - 2017/6/1

N2 - Objective:: This study is aimed at measuring the ripple of magnetic power supply of BEPCII and checking its effect to beam energy. Materials and methods:: A sensor made of printed circuit board coils is designed and manufactured. The sensor was inserted into a good area region of the magnetic field with the surface perpendicular to the field force lines. The change of the magnetic field would be detected according to Faraday’s law. Results:: The experiment result indicates that the time-dependent ripple of the magnetic field is in the magnitude of ppm. Conclusion:: Such a small effect of the time-dependent ripplecan be negligibleto beam energy.

AB - Objective:: This study is aimed at measuring the ripple of magnetic power supply of BEPCII and checking its effect to beam energy. Materials and methods:: A sensor made of printed circuit board coils is designed and manufactured. The sensor was inserted into a good area region of the magnetic field with the surface perpendicular to the field force lines. The change of the magnetic field would be detected according to Faraday’s law. Results:: The experiment result indicates that the time-dependent ripple of the magnetic field is in the magnitude of ppm. Conclusion:: Such a small effect of the time-dependent ripplecan be negligibleto beam energy.

KW - 29.00.00

KW - 29.30.Kv

KW - 78.40.Fy

KW - Beam energy measurement

KW - HPGe detector

KW - Laser

KW - MEASUREMENT SYSTEM

UR - http://www.scopus.com/inward/record.url?scp=85059447936&partnerID=8YFLogxK

U2 - 10.1007/s41605-017-0008-0

DO - 10.1007/s41605-017-0008-0

M3 - Article

AN - SCOPUS:85059447936

VL - 1

JO - Radiation Detection Technology and Methods

JF - Radiation Detection Technology and Methods

SN - 2509-9930

IS - 1

M1 - 7

ER -