Measurement of the lithium layer thickness using a proton beam. / Касатов, Дмитрий Александрович; Кошкарев, Алексей Михайлович; Макаров, Александр Николаевич и др.
19th International Congress on Neutron Capture Therapy Granada, Spain, September 27th - October 1st, 2021. Book of Abstacts. Вена : International Atomic Energy Agency, 2021. стр. 96 Р10.Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
}
TY - GEN
T1 - Measurement of the lithium layer thickness using a proton beam
AU - Касатов, Дмитрий Александрович
AU - Кошкарев, Алексей Михайлович
AU - Макаров, Александр Николаевич
AU - Соколова, Евгения Олеговна
AU - Щудло, Иван Михайлович
AU - Таскаев, Сергей Юрьевич
N1 - Conference code: 19
PY - 2021
Y1 - 2021
N2 - In Budker Institute of Nuclear Physics an epithermal neutron source based on a tandem accelerator with vacuum insulation and a solid lithium target for 7 Li(p,n)7 Be reaction was developed. Lithium target is prepared by thermal vacuum evaporation of the thin (typically 60 µm) lithium layer on the water cooled substrate. Average thickness of the layer is calculated knowing the mass of evaporated lithium, but the distribution of the deposited lithium was still unknown. Due to fast oxidation of the lithium in air and its poor mechanical properties direct measurement of the lithium layer thickness is a challenging task. In this work we proposed and realized two different methods for measurement of the lithium distribution over the substrate surface. For this purpose we irradiated different spots of the target by collimated 2 mm proton beam along one axis. Scanning along x-axis is performed using flexible connection between accelerator and lithium target and actuator for target movement. For the first method we used 1.8 MeV protons and measured by a HPGe gamma-spectrometer the intensity of the emitted 478 keV photons in each spot. Lithium thickness distribution is calculated knowing the 7 Li(p,p'γ) 7 Li reaction cross section and 478 keV photon yield from a thick lithium target that we have measured previously [1]. For the second method we used 2.05 MeV protons scanning over lithium target with average thickness of 7 µm and a neutron dosimeter for neutron yield measurement. In this case neutron yield is directly dependent on lithium thickness. The results of the measurements by two methods are compared and presented in this work. These two measurements are in good agreement with calculations and with each other.
AB - In Budker Institute of Nuclear Physics an epithermal neutron source based on a tandem accelerator with vacuum insulation and a solid lithium target for 7 Li(p,n)7 Be reaction was developed. Lithium target is prepared by thermal vacuum evaporation of the thin (typically 60 µm) lithium layer on the water cooled substrate. Average thickness of the layer is calculated knowing the mass of evaporated lithium, but the distribution of the deposited lithium was still unknown. Due to fast oxidation of the lithium in air and its poor mechanical properties direct measurement of the lithium layer thickness is a challenging task. In this work we proposed and realized two different methods for measurement of the lithium distribution over the substrate surface. For this purpose we irradiated different spots of the target by collimated 2 mm proton beam along one axis. Scanning along x-axis is performed using flexible connection between accelerator and lithium target and actuator for target movement. For the first method we used 1.8 MeV protons and measured by a HPGe gamma-spectrometer the intensity of the emitted 478 keV photons in each spot. Lithium thickness distribution is calculated knowing the 7 Li(p,p'γ) 7 Li reaction cross section and 478 keV photon yield from a thick lithium target that we have measured previously [1]. For the second method we used 2.05 MeV protons scanning over lithium target with average thickness of 7 µm and a neutron dosimeter for neutron yield measurement. In this case neutron yield is directly dependent on lithium thickness. The results of the measurements by two methods are compared and presented in this work. These two measurements are in good agreement with calculations and with each other.
UR - https://elibrary.ru/item.asp?pff=1&id=47962111
M3 - Conference contribution
SP - 96
BT - 19th International Congress on Neutron Capture Therapy Granada, Spain, September 27th - October 1st, 2021. Book of Abstacts
PB - International Atomic Energy Agency
CY - Вена
T2 - 19th International Congress on Neutron Capture Therapy
Y2 - 27 September 2021 through 1 October 2021
ER -
ID: 34998881