Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Luminosity online monitor for the Belle II detector. / Kovalenko, E.; Aulchenko, V.; Bondar, A. и др.
в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 1079, 170614, 10.2025.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Luminosity online monitor for the Belle II detector
AU - Kovalenko, E.
AU - Aulchenko, V.
AU - Bondar, A.
AU - Cheon, B. G.
AU - Garmash, A.
AU - Nakamura, I.
AU - Kania, K.
AU - Kozyrev, A.
AU - Kuzmin, A.
AU - Remnev, M.
AU - Shebalin, V.
AU - Shwartz, B.
AU - Unno, Y.
AU - Usov, Y.
AU - Zhilich, V.
PY - 2025/10
Y1 - 2025/10
N2 - To provide real-time luminosity values in the Belle II experiment at the SuperKEKB collider, the standalone system was designed. It evaluates luminosity from counting rate of Bhabha and two photon annihilation events based on the Belle II electromagnetic calorimeter information. At the design luminosity of 6×1035 cm−2s−1 the system will provide a counting rate of 18 kHz with systematic accuracy of 0.8% and statistical accuracy of 0.7% for the one second integration time. For the currently achieved luminosity, the statistical accuracy is 2.6%.
AB - To provide real-time luminosity values in the Belle II experiment at the SuperKEKB collider, the standalone system was designed. It evaluates luminosity from counting rate of Bhabha and two photon annihilation events based on the Belle II electromagnetic calorimeter information. At the design luminosity of 6×1035 cm−2s−1 the system will provide a counting rate of 18 kHz with systematic accuracy of 0.8% and statistical accuracy of 0.7% for the one second integration time. For the currently achieved luminosity, the statistical accuracy is 2.6%.
KW - Electromagnetic calorimeter
KW - Luminosity
KW - e+e− colliders
UR - https://www.mendeley.com/catalogue/8daee826-f0d7-3fc2-8bc0-17c845e43b85/
UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-105005589227&origin=inward&txGid=4836ab94febdf5942b56c8774352297e
U2 - 10.1016/j.nima.2025.170614
DO - 10.1016/j.nima.2025.170614
M3 - Article
VL - 1079
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
M1 - 170614
ER -