Standard

Kinetic titration method in flow cytometry for quantification of cell receptors. / Khalo, Irina V; Karpenko, Andrei A; Kozyreva, Viktoriya S и др.

в: Journal of immunological methods, Том 521, 113555, 10.2023.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Khalo, IV, Karpenko, AA, Kozyreva, VS, Shilova, AN, Abubakirova, OA, Strokotov, DI, Nekrasov, VM, Maltsev, VP & Chernyshev, AV 2023, 'Kinetic titration method in flow cytometry for quantification of cell receptors', Journal of immunological methods, Том. 521, 113555. https://doi.org/10.1016/j.jim.2023.113555

APA

Khalo, I. V., Karpenko, A. A., Kozyreva, V. S., Shilova, A. N., Abubakirova, O. A., Strokotov, D. I., Nekrasov, V. M., Maltsev, V. P., & Chernyshev, A. V. (2023). Kinetic titration method in flow cytometry for quantification of cell receptors. Journal of immunological methods, 521, [113555]. https://doi.org/10.1016/j.jim.2023.113555

Vancouver

Khalo IV, Karpenko AA, Kozyreva VS, Shilova AN, Abubakirova OA, Strokotov DI и др. Kinetic titration method in flow cytometry for quantification of cell receptors. Journal of immunological methods. 2023 окт.;521:113555. Epub 2023 сент. 2. doi: 10.1016/j.jim.2023.113555

Author

Khalo, Irina V ; Karpenko, Andrei A ; Kozyreva, Viktoriya S и др. / Kinetic titration method in flow cytometry for quantification of cell receptors. в: Journal of immunological methods. 2023 ; Том 521.

BibTeX

@article{293e73f94a5745ea9f310ea2dc63f943,
title = "Kinetic titration method in flow cytometry for quantification of cell receptors",
abstract = "For the quantitative determination of cell receptors by fluorescence flow cytometry, we proposed a new method, which takes into account the reaction kinetics. The binding reaction of the ligand with receptors begins after placing the cells in the ligand solution. In the proposed method, there are several samples with the same concentration of cells and different initial concentrations of fluorescently labeled ligand, and each sample is measured by a flow cytometer once at the time when the following condition is met: the product of the incubation time (cells with ligand) and the initial concentration of ligand is the same for all samples. The proposed approach eliminates disadvantages and combines advantages of both kinetic and titration methods for quantification of receptors on single cells without the use of traditional calibration fluorescent beads. Practical application of the method was demonstrated in quantification of CD8 and CD14 on peripheral blood human leukocytes. Particularly, we found decreased (by a factor of two) mean number of CD14 on monocytes and granulocytes in patients with atherosclerosis (treated in the hospital) compared to conditionally healthy donors, whereas no difference was found in the mean CD8 expression on leukocytes between the same patient and donor groups.",
keywords = "Flow Cytometry, Humans, Kinetics, Leukocytes, Ligands, Receptors, Cell Surface",
author = "Khalo, {Irina V} and Karpenko, {Andrei A} and Kozyreva, {Viktoriya S} and Shilova, {Anna N} and Abubakirova, {Olga A} and Strokotov, {Dmitry I} and Nekrasov, {Vyacheslav M} and Maltsev, {Valeri P} and Chernyshev, {Andrei V}",
note = "This work was supported by Russian Science Foundation (grant 17-75-20117). Copyright {\textcopyright} 2023. Published by Elsevier B.V.",
year = "2023",
month = oct,
doi = "10.1016/j.jim.2023.113555",
language = "English",
volume = "521",
journal = "Journal of immunological methods",
issn = "0022-1759",
publisher = "Elsevier Science Publishing Company, Inc.",

}

RIS

TY - JOUR

T1 - Kinetic titration method in flow cytometry for quantification of cell receptors

AU - Khalo, Irina V

AU - Karpenko, Andrei A

AU - Kozyreva, Viktoriya S

AU - Shilova, Anna N

AU - Abubakirova, Olga A

AU - Strokotov, Dmitry I

AU - Nekrasov, Vyacheslav M

AU - Maltsev, Valeri P

AU - Chernyshev, Andrei V

N1 - This work was supported by Russian Science Foundation (grant 17-75-20117). Copyright © 2023. Published by Elsevier B.V.

PY - 2023/10

Y1 - 2023/10

N2 - For the quantitative determination of cell receptors by fluorescence flow cytometry, we proposed a new method, which takes into account the reaction kinetics. The binding reaction of the ligand with receptors begins after placing the cells in the ligand solution. In the proposed method, there are several samples with the same concentration of cells and different initial concentrations of fluorescently labeled ligand, and each sample is measured by a flow cytometer once at the time when the following condition is met: the product of the incubation time (cells with ligand) and the initial concentration of ligand is the same for all samples. The proposed approach eliminates disadvantages and combines advantages of both kinetic and titration methods for quantification of receptors on single cells without the use of traditional calibration fluorescent beads. Practical application of the method was demonstrated in quantification of CD8 and CD14 on peripheral blood human leukocytes. Particularly, we found decreased (by a factor of two) mean number of CD14 on monocytes and granulocytes in patients with atherosclerosis (treated in the hospital) compared to conditionally healthy donors, whereas no difference was found in the mean CD8 expression on leukocytes between the same patient and donor groups.

AB - For the quantitative determination of cell receptors by fluorescence flow cytometry, we proposed a new method, which takes into account the reaction kinetics. The binding reaction of the ligand with receptors begins after placing the cells in the ligand solution. In the proposed method, there are several samples with the same concentration of cells and different initial concentrations of fluorescently labeled ligand, and each sample is measured by a flow cytometer once at the time when the following condition is met: the product of the incubation time (cells with ligand) and the initial concentration of ligand is the same for all samples. The proposed approach eliminates disadvantages and combines advantages of both kinetic and titration methods for quantification of receptors on single cells without the use of traditional calibration fluorescent beads. Practical application of the method was demonstrated in quantification of CD8 and CD14 on peripheral blood human leukocytes. Particularly, we found decreased (by a factor of two) mean number of CD14 on monocytes and granulocytes in patients with atherosclerosis (treated in the hospital) compared to conditionally healthy donors, whereas no difference was found in the mean CD8 expression on leukocytes between the same patient and donor groups.

KW - Flow Cytometry

KW - Humans

KW - Kinetics

KW - Leukocytes

KW - Ligands

KW - Receptors, Cell Surface

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85171547329&origin=inward&txGid=1d286b52dc57b479ff7a9ed6694939e2

UR - https://www.mendeley.com/catalogue/251746a0-5bff-36ee-811c-896de035f8bd/

U2 - 10.1016/j.jim.2023.113555

DO - 10.1016/j.jim.2023.113555

M3 - Article

C2 - 37666317

VL - 521

JO - Journal of immunological methods

JF - Journal of immunological methods

SN - 0022-1759

M1 - 113555

ER -

ID: 55076509