Standard

Initial trials of a dose monitoring detector for boron neutron capture therapy. / Bykov, T. A.; Kasatov, D. A.; Koshkarev, A. M. и др.

в: Journal of Instrumentation, Том 16, № 1, P01024, 01.2021.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Bykov TA, Kasatov DA, Koshkarev AM, Makarov AN, Porosev VV, Savinov GA и др. Initial trials of a dose monitoring detector for boron neutron capture therapy. Journal of Instrumentation. 2021 янв.;16(1):P01024. doi: 10.1088/1748-0221/16/01/P01024

Author

BibTeX

@article{05704a3f621140108496e33518b7862b,
title = "Initial trials of a dose monitoring detector for boron neutron capture therapy",
abstract = "In this study, we present results of initial trials of a scintillator-over-fiber detector system with a silicon photomultiplier readout designed at Budker Institute of Nuclear Physics. The results demonstrate that the proposed system, using a pair of boron-enriched and boron-free scintillators, could be successfully used for monitoring of thermal neutron flux and estimation of irradiation dose. Nevertheless, it is necessary to optimize the design of the detector head components to ensure long time detector stability with heavy radiation background.",
keywords = "APDs, CCDs, CMOS imagers, Dosimetry concepts and apparatus; Neutron detectors (cold, EBCCDs, EMCCDs, Etc); Scintillators, Fast neutrons); Photon detectors for UV, G-APDs, Gas, Liquid scintillators), Scintillation and light emission processes (solid, Si-PMTs, Thermal, Visible and IR photons (solid-state) (PIN diodes",
author = "Bykov, {T. A.} and Kasatov, {D. A.} and Koshkarev, {A. M.} and Makarov, {A. N.} and Porosev, {V. V.} and Savinov, {G. A.} and Shchudlo, {I. M.} and Taskaev, {S. Yu} and Verkhovod, {G. D.}",
note = "Funding Information: The research is partially supported by a grant of the Russian Science Foundation (project No. 19-72-30005). Publisher Copyright: {\textcopyright} 2021 Institute of Physics Publishing. All rights reserved. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.",
year = "2021",
month = jan,
doi = "10.1088/1748-0221/16/01/P01024",
language = "English",
volume = "16",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Initial trials of a dose monitoring detector for boron neutron capture therapy

AU - Bykov, T. A.

AU - Kasatov, D. A.

AU - Koshkarev, A. M.

AU - Makarov, A. N.

AU - Porosev, V. V.

AU - Savinov, G. A.

AU - Shchudlo, I. M.

AU - Taskaev, S. Yu

AU - Verkhovod, G. D.

N1 - Funding Information: The research is partially supported by a grant of the Russian Science Foundation (project No. 19-72-30005). Publisher Copyright: © 2021 Institute of Physics Publishing. All rights reserved. Copyright: Copyright 2021 Elsevier B.V., All rights reserved.

PY - 2021/1

Y1 - 2021/1

N2 - In this study, we present results of initial trials of a scintillator-over-fiber detector system with a silicon photomultiplier readout designed at Budker Institute of Nuclear Physics. The results demonstrate that the proposed system, using a pair of boron-enriched and boron-free scintillators, could be successfully used for monitoring of thermal neutron flux and estimation of irradiation dose. Nevertheless, it is necessary to optimize the design of the detector head components to ensure long time detector stability with heavy radiation background.

AB - In this study, we present results of initial trials of a scintillator-over-fiber detector system with a silicon photomultiplier readout designed at Budker Institute of Nuclear Physics. The results demonstrate that the proposed system, using a pair of boron-enriched and boron-free scintillators, could be successfully used for monitoring of thermal neutron flux and estimation of irradiation dose. Nevertheless, it is necessary to optimize the design of the detector head components to ensure long time detector stability with heavy radiation background.

KW - APDs

KW - CCDs

KW - CMOS imagers

KW - Dosimetry concepts and apparatus; Neutron detectors (cold

KW - EBCCDs

KW - EMCCDs

KW - Etc); Scintillators

KW - Fast neutrons); Photon detectors for UV

KW - G-APDs

KW - Gas

KW - Liquid scintillators)

KW - Scintillation and light emission processes (solid

KW - Si-PMTs

KW - Thermal

KW - Visible and IR photons (solid-state) (PIN diodes

UR - http://www.scopus.com/inward/record.url?scp=85099791553&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/16/01/P01024

DO - 10.1088/1748-0221/16/01/P01024

M3 - Article

AN - SCOPUS:85099791553

VL - 16

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 1

M1 - P01024

ER -

ID: 27640741