Standard

Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements. / Alymov, A. O.; Balkov, E. V.; Beloborodov, V. A.

Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition. European Association of Geoscientists and Engineers, EAGE, 2018.

Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференцийстатья в сборнике материалов конференциинаучнаяРецензирование

Harvard

Alymov, AO, Balkov, EV & Beloborodov, VA 2018, Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements. в Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition. European Association of Geoscientists and Engineers, EAGE, 14th Conference and Exhibition on Engineering and Mining Geophysics 2018, Almaty, Казахстан, 23.04.2018.

APA

Alymov, A. O., Balkov, E. V., & Beloborodov, V. A. (2018). Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements. в Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition European Association of Geoscientists and Engineers, EAGE.

Vancouver

Alymov AO, Balkov EV, Beloborodov VA. Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements. в Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition. European Association of Geoscientists and Engineers, EAGE. 2018

Author

Alymov, A. O. ; Balkov, E. V. ; Beloborodov, V. A. / Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements. Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition. European Association of Geoscientists and Engineers, EAGE, 2018.

BibTeX

@inproceedings{397752fc1f9e443e8be8391e0f2c1b95,
title = "Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements",
abstract = "DC resistivity data by using computer-controlled multi-channel multi-electrode arrays is be popular. While, acquisition speed are enormous, optimization of the measurement technique is necessary, in order to gather without loss of data quality. The analysis of field data from multi-channel resistivity-meter {"}Skala 64{"} shows that electrode charge-up effect is cause significant distortions of measuring potentials. This effect can be larger than the induced signal and have a significant amplitude during all time of measurements. Influence of electrode grounding resistance is much lower. An algorithm for linear correction had been realized and tested. If there is a short delay before measuring potentials is provided after an electrode is used for transmitting current, correction of the linear drift allows to exclude influence of charge-up effects.",
author = "Alymov, {A. O.} and Balkov, {E. V.} and Beloborodov, {V. A.}",
year = "2018",
month = jan,
day = "1",
language = "English",
booktitle = "Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition",
publisher = "European Association of Geoscientists and Engineers, EAGE",
note = "14th Conference and Exhibition on Engineering and Mining Geophysics 2018 ; Conference date: 23-04-2018 Through 27-04-2018",

}

RIS

TY - GEN

T1 - Influence of electrode grounding resistance and churge-up effect on quality of cves-measurements

AU - Alymov, A. O.

AU - Balkov, E. V.

AU - Beloborodov, V. A.

PY - 2018/1/1

Y1 - 2018/1/1

N2 - DC resistivity data by using computer-controlled multi-channel multi-electrode arrays is be popular. While, acquisition speed are enormous, optimization of the measurement technique is necessary, in order to gather without loss of data quality. The analysis of field data from multi-channel resistivity-meter "Skala 64" shows that electrode charge-up effect is cause significant distortions of measuring potentials. This effect can be larger than the induced signal and have a significant amplitude during all time of measurements. Influence of electrode grounding resistance is much lower. An algorithm for linear correction had been realized and tested. If there is a short delay before measuring potentials is provided after an electrode is used for transmitting current, correction of the linear drift allows to exclude influence of charge-up effects.

AB - DC resistivity data by using computer-controlled multi-channel multi-electrode arrays is be popular. While, acquisition speed are enormous, optimization of the measurement technique is necessary, in order to gather without loss of data quality. The analysis of field data from multi-channel resistivity-meter "Skala 64" shows that electrode charge-up effect is cause significant distortions of measuring potentials. This effect can be larger than the induced signal and have a significant amplitude during all time of measurements. Influence of electrode grounding resistance is much lower. An algorithm for linear correction had been realized and tested. If there is a short delay before measuring potentials is provided after an electrode is used for transmitting current, correction of the linear drift allows to exclude influence of charge-up effects.

UR - http://www.scopus.com/inward/record.url?scp=85050519910&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:85050519910

BT - Engineering and Mining Geophysics 2018 - 14th Conference and Exhibition

PB - European Association of Geoscientists and Engineers, EAGE

T2 - 14th Conference and Exhibition on Engineering and Mining Geophysics 2018

Y2 - 23 April 2018 through 27 April 2018

ER -

ID: 15967233