Standard

Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis. / Shalaev, Pavel V.; Bondina, Ekaterina V.; Dolgushin, Sergey A. и др.

European Conference on Biomedical Optics, ECBO_2019. ред. / JC Brown; TG VanLeeuwen. OSA - The Optical Society, 2019. (Optics InfoBase Conference Papers; Том Part F142-ECBO 2019).

Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференцийстатья в сборнике материалов конференциинаучнаяРецензирование

Harvard

Shalaev, PV, Bondina, EV, Dolgushin, SA, Semeykina, VS, Sankova, NN & Parkhomchuk, EV 2019, Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis. в JC Brown & TG VanLeeuwen (ред.), European Conference on Biomedical Optics, ECBO_2019. Optics InfoBase Conference Papers, Том. Part F142-ECBO 2019, OSA - The Optical Society, European Conference on Biomedical Optics, ECBO_2019, Munich, Нидерланды, 23.06.2019. https://doi.org/10.1117/12.2526387

APA

Shalaev, P. V., Bondina, E. V., Dolgushin, S. A., Semeykina, V. S., Sankova, N. N., & Parkhomchuk, E. V. (2019). Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis. в JC. Brown, & TG. VanLeeuwen (Ред.), European Conference on Biomedical Optics, ECBO_2019 (Optics InfoBase Conference Papers; Том Part F142-ECBO 2019). OSA - The Optical Society. https://doi.org/10.1117/12.2526387

Vancouver

Shalaev PV, Bondina EV, Dolgushin SA, Semeykina VS, Sankova NN, Parkhomchuk EV. Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis. в Brown JC, VanLeeuwen TG, Редакторы, European Conference on Biomedical Optics, ECBO_2019. OSA - The Optical Society. 2019. (Optics InfoBase Conference Papers). doi: 10.1117/12.2526387

Author

Shalaev, Pavel V. ; Bondina, Ekaterina V. ; Dolgushin, Sergey A. и др. / Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis. European Conference on Biomedical Optics, ECBO_2019. Редактор / JC Brown ; TG VanLeeuwen. OSA - The Optical Society, 2019. (Optics InfoBase Conference Papers).

BibTeX

@inproceedings{2e2cc09bd57d46ce9cb90382f8b9af85,
title = "Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis",
abstract = "Samples of liquid dispersions of 4 µm polystyrene microspheres with cyanine 5 and cyanine 5.5 dyes were synthesized and studied using developed experimental setup for fluorescence microscopy. It was shown the possibility of identification of microspheres with different dyes and different dye concentration in the image. The low coefficient of variation of fluorescence intensity in the image makes it possible to use a large number of types of spectrally encoded microspheres in the immunofluorescence analysis.",
keywords = "Cyanine dyes, Immunofluorescence analysis, Polystyrene microspheres, polystyrene microspheres, immunofluorescence analysis, cyanine dyes",
author = "Shalaev, {Pavel V.} and Bondina, {Ekaterina V.} and Dolgushin, {Sergey A.} and Semeykina, {Victoria S.} and Sankova, {Natalya N.} and Parkhomchuk, {Ekaterina V.}",
year = "2019",
month = jul,
day = "19",
doi = "10.1117/12.2526387",
language = "English",
series = "Optics InfoBase Conference Papers",
publisher = "OSA - The Optical Society",
editor = "JC Brown and TG VanLeeuwen",
booktitle = "European Conference on Biomedical Optics, ECBO_2019",
note = "European Conference on Biomedical Optics, ECBO_2019 ; Conference date: 23-06-2019 Through 25-06-2019",

}

RIS

TY - GEN

T1 - Fluorescent imaging of polystyrene microspheres with cyanine dyes for immunofluorescence analysis

AU - Shalaev, Pavel V.

AU - Bondina, Ekaterina V.

AU - Dolgushin, Sergey A.

AU - Semeykina, Victoria S.

AU - Sankova, Natalya N.

AU - Parkhomchuk, Ekaterina V.

PY - 2019/7/19

Y1 - 2019/7/19

N2 - Samples of liquid dispersions of 4 µm polystyrene microspheres with cyanine 5 and cyanine 5.5 dyes were synthesized and studied using developed experimental setup for fluorescence microscopy. It was shown the possibility of identification of microspheres with different dyes and different dye concentration in the image. The low coefficient of variation of fluorescence intensity in the image makes it possible to use a large number of types of spectrally encoded microspheres in the immunofluorescence analysis.

AB - Samples of liquid dispersions of 4 µm polystyrene microspheres with cyanine 5 and cyanine 5.5 dyes were synthesized and studied using developed experimental setup for fluorescence microscopy. It was shown the possibility of identification of microspheres with different dyes and different dye concentration in the image. The low coefficient of variation of fluorescence intensity in the image makes it possible to use a large number of types of spectrally encoded microspheres in the immunofluorescence analysis.

KW - Cyanine dyes

KW - Immunofluorescence analysis

KW - Polystyrene microspheres

KW - polystyrene microspheres

KW - immunofluorescence analysis

KW - cyanine dyes

UR - http://www.scopus.com/inward/record.url?scp=85084488383&partnerID=8YFLogxK

U2 - 10.1117/12.2526387

DO - 10.1117/12.2526387

M3 - Conference contribution

AN - SCOPUS:85084488383

T3 - Optics InfoBase Conference Papers

BT - European Conference on Biomedical Optics, ECBO_2019

A2 - Brown, JC

A2 - VanLeeuwen, TG

PB - OSA - The Optical Society

T2 - European Conference on Biomedical Optics, ECBO_2019

Y2 - 23 June 2019 through 25 June 2019

ER -