Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Effect of covalent and non-covalent linking of zinc(II) phthalocyanine functionalised carbon nanomaterials on the sensor response to ammonia. / Polyakov, Maxim S.; Basova, Tamara V.; Göksel, Meltem и др.
в: Synthetic Metals, Том 227, 01.05.2017, стр. 78-86.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Effect of covalent and non-covalent linking of zinc(II) phthalocyanine functionalised carbon nanomaterials on the sensor response to ammonia
AU - Polyakov, Maxim S.
AU - Basova, Tamara V.
AU - Göksel, Meltem
AU - Şenocak, Ahmet
AU - Demirbaş, Erhan
AU - Durmuş, Mahmut
AU - Kadem, Burak
AU - Hassan, Aseel
PY - 2017/5/1
Y1 - 2017/5/1
N2 - In this work, a comparative study of the sensor response of single walled carbon nanotubes (SWCNTs) and reduced graphene oxide (rGO) covalently and non-covalently functionalised with1-[N-(2-ethoxyethyl)-4-pentynamide]-8(11),15(18),22(25)-tris-{2-[2-(2-ethoxyethoxy) ethoxy]-1-[2-((2-ethoxy ethoxy)-ethoxy)methyl]ethyloxy}zinc(II) phthalocyanine (ZnPc) to ammonia is carried out. It was shown that in the case of SWCNT-based materials both covalent and non-covalent functionalisation with zinc(II) phthalocyanine leads to the increase of the sensor response toward NH3, while functionalisation of reduced graphene oxide causes a decrease in the response. At the same time both covalent and non-covalent linking of zinc(II) phthalocyanine leads to twofold decrease of the sensor recovery times. The sensor response of the carbon nanomaterial (single walled carbon nanotubes or reduced graphene oxide) hybrids covalently functionalised with zinc(II) phthalocyanine is several times higher than in the case of non-covalent linking of zinc(II) phthalocyanine to these nanomaterials, which is in good correlation with the number of zinc(II) phthalocyanine molecules adsorbed onto the SWCNT and rGO walls.
AB - In this work, a comparative study of the sensor response of single walled carbon nanotubes (SWCNTs) and reduced graphene oxide (rGO) covalently and non-covalently functionalised with1-[N-(2-ethoxyethyl)-4-pentynamide]-8(11),15(18),22(25)-tris-{2-[2-(2-ethoxyethoxy) ethoxy]-1-[2-((2-ethoxy ethoxy)-ethoxy)methyl]ethyloxy}zinc(II) phthalocyanine (ZnPc) to ammonia is carried out. It was shown that in the case of SWCNT-based materials both covalent and non-covalent functionalisation with zinc(II) phthalocyanine leads to the increase of the sensor response toward NH3, while functionalisation of reduced graphene oxide causes a decrease in the response. At the same time both covalent and non-covalent linking of zinc(II) phthalocyanine leads to twofold decrease of the sensor recovery times. The sensor response of the carbon nanomaterial (single walled carbon nanotubes or reduced graphene oxide) hybrids covalently functionalised with zinc(II) phthalocyanine is several times higher than in the case of non-covalent linking of zinc(II) phthalocyanine to these nanomaterials, which is in good correlation with the number of zinc(II) phthalocyanine molecules adsorbed onto the SWCNT and rGO walls.
KW - Ammonia sensor
KW - Carbon nanomaterials
KW - Covalent functionalisation
KW - Non- covalent functionalisation
KW - Phthalocyanine
KW - REDUCED GRAPHENE OXIDE
KW - METAL-PHTHALOCYANINE
KW - ROOM-TEMPERATURE
KW - CHEMICAL SENSORS
KW - ADSORPTION
KW - NANOPARTICLES
KW - HYBRID MATERIAL
KW - SENSING PERFORMANCE
KW - NANOTUBES
KW - GAS SENSOR
UR - http://www.scopus.com/inward/record.url?scp=85016145634&partnerID=8YFLogxK
U2 - 10.1016/j.synthmet.2017.02.024
DO - 10.1016/j.synthmet.2017.02.024
M3 - Article
AN - SCOPUS:85016145634
VL - 227
SP - 78
EP - 86
JO - Synthetic Metals
JF - Synthetic Metals
SN - 0379-6779
ER -
ID: 10267210