Standard

Determination of elemental impurities Cd, Pb, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, Mo, Al, and Fe in highly potent analgesic activity agent by microwave-induced plasma optical emission spectrometry (MIP OES). / Zubricheva, Daria V.; Lastovka, Anastasiya V.; Il’ina, Irina V. и др.

в: Chemical Papers, Том 76, № 9, 09.2022, стр. 5677-5689.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Zubricheva DV, Lastovka AV, Il’ina IV, Volcho KP, Tikhova VD, Fadeeva VP и др. Determination of elemental impurities Cd, Pb, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, Mo, Al, and Fe in highly potent analgesic activity agent by microwave-induced plasma optical emission spectrometry (MIP OES). Chemical Papers. 2022 сент.;76(9):5677-5689. doi: 10.1007/s11696-022-02275-0

Author

BibTeX

@article{a5507c1c487a4cc983828ae320ca9620,
title = "Determination of elemental impurities Cd, Pb, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, Mo, Al, and Fe in highly potent analgesic activity agent by microwave-induced plasma optical emission spectrometry (MIP OES)",
abstract = "Two methods for quantifying elemental impurities in a highly potent analgesic activity agent (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol have been developed using acid decomposition assisted by microwave digestion system or heating in metallic block followed by analyte determination using microwave-induced plasma optical emission spectrometry (MIP OES). Both methods have been validated. The fast linear interference correction (FLIC) and inter-element correction (IEC) methods have been used to take into account possible spectral interferences. Arsenic and mercury have been determined using the multimode sample introduction system (MSIS). The detection limits have been calculated (µg L−1) – 5.4 for Cd, 5.1 for Pb, 11 for As, 1.3 for Hg, 10 for Co, 2.4 for V, 1.4 for Ni. The accuracy of the results was established using an independent inductively coupled plasma mass spectrometry (ICP-MS) method. The relative standard deviation (RSD) (n ≥ 4) was ≤ 12% for Cd, 3.8% for Pb, 6.2% for As, 11% for Hg, 3.0% for V (sample decomposition assisted by heating on metallic block), and 10% for Ni (sample decomposition assisted by microwave radiation). It was shown that the concentration of Cd, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, and Mo as impurities in (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol was lower than the upper limit concentration.",
keywords = "Analgesic activity agent, MIP OES, Sample decomposition",
author = "Zubricheva, {Daria V.} and Lastovka, {Anastasiya V.} and Il{\textquoteright}ina, {Irina V.} and Volcho, {Konstantin P.} and Tikhova, {Vera D.} and Fadeeva, {Valentina P.} and Salakhutdinov, {Nariman F.}",
note = "Funding Information: Authors would like to acknowledge the Multi-Access Chemical Research Center SB RAS for spectral and analytical measurements Publisher Copyright: {\textcopyright} 2022, Institute of Chemistry, Slovak Academy of Sciences.",
year = "2022",
month = sep,
doi = "10.1007/s11696-022-02275-0",
language = "English",
volume = "76",
pages = "5677--5689",
journal = "Chemical Papers",
issn = "0366-6352",
publisher = "Springer International Publishing AG",
number = "9",

}

RIS

TY - JOUR

T1 - Determination of elemental impurities Cd, Pb, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, Mo, Al, and Fe in highly potent analgesic activity agent by microwave-induced plasma optical emission spectrometry (MIP OES)

AU - Zubricheva, Daria V.

AU - Lastovka, Anastasiya V.

AU - Il’ina, Irina V.

AU - Volcho, Konstantin P.

AU - Tikhova, Vera D.

AU - Fadeeva, Valentina P.

AU - Salakhutdinov, Nariman F.

N1 - Funding Information: Authors would like to acknowledge the Multi-Access Chemical Research Center SB RAS for spectral and analytical measurements Publisher Copyright: © 2022, Institute of Chemistry, Slovak Academy of Sciences.

PY - 2022/9

Y1 - 2022/9

N2 - Two methods for quantifying elemental impurities in a highly potent analgesic activity agent (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol have been developed using acid decomposition assisted by microwave digestion system or heating in metallic block followed by analyte determination using microwave-induced plasma optical emission spectrometry (MIP OES). Both methods have been validated. The fast linear interference correction (FLIC) and inter-element correction (IEC) methods have been used to take into account possible spectral interferences. Arsenic and mercury have been determined using the multimode sample introduction system (MSIS). The detection limits have been calculated (µg L−1) – 5.4 for Cd, 5.1 for Pb, 11 for As, 1.3 for Hg, 10 for Co, 2.4 for V, 1.4 for Ni. The accuracy of the results was established using an independent inductively coupled plasma mass spectrometry (ICP-MS) method. The relative standard deviation (RSD) (n ≥ 4) was ≤ 12% for Cd, 3.8% for Pb, 6.2% for As, 11% for Hg, 3.0% for V (sample decomposition assisted by heating on metallic block), and 10% for Ni (sample decomposition assisted by microwave radiation). It was shown that the concentration of Cd, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, and Mo as impurities in (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol was lower than the upper limit concentration.

AB - Two methods for quantifying elemental impurities in a highly potent analgesic activity agent (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol have been developed using acid decomposition assisted by microwave digestion system or heating in metallic block followed by analyte determination using microwave-induced plasma optical emission spectrometry (MIP OES). Both methods have been validated. The fast linear interference correction (FLIC) and inter-element correction (IEC) methods have been used to take into account possible spectral interferences. Arsenic and mercury have been determined using the multimode sample introduction system (MSIS). The detection limits have been calculated (µg L−1) – 5.4 for Cd, 5.1 for Pb, 11 for As, 1.3 for Hg, 10 for Co, 2.4 for V, 1.4 for Ni. The accuracy of the results was established using an independent inductively coupled plasma mass spectrometry (ICP-MS) method. The relative standard deviation (RSD) (n ≥ 4) was ≤ 12% for Cd, 3.8% for Pb, 6.2% for As, 11% for Hg, 3.0% for V (sample decomposition assisted by heating on metallic block), and 10% for Ni (sample decomposition assisted by microwave radiation). It was shown that the concentration of Cd, As, Hg, Co, V, Ni, Pd, Ru, Ag, Pt, and Mo as impurities in (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol was lower than the upper limit concentration.

KW - Analgesic activity agent

KW - MIP OES

KW - Sample decomposition

UR - http://www.scopus.com/inward/record.url?scp=85136785744&partnerID=8YFLogxK

UR - https://www.mendeley.com/catalogue/b41231b9-4033-3672-a6b5-009a444149d9/

U2 - 10.1007/s11696-022-02275-0

DO - 10.1007/s11696-022-02275-0

M3 - Article

AN - SCOPUS:85136785744

VL - 76

SP - 5677

EP - 5689

JO - Chemical Papers

JF - Chemical Papers

SN - 0366-6352

IS - 9

ER -

ID: 37069195