Standard

Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider. / Kremnev, N. S.; Bryzgunov, M. I.; Bubley, A. V. и др.

в: Physics of Particles and Nuclei Letters, Том 17, № 4, 01.07.2020, стр. 438-442.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Kremnev, NS, Bryzgunov, MI, Bubley, AV, Parkhomchuk, VV, Panasyuk, VM, Reva, VB, Putmakov, AA, Pospolita, SP & Shiyankov, SV 2020, 'Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider', Physics of Particles and Nuclei Letters, Том. 17, № 4, стр. 438-442. https://doi.org/10.1134/S1547477120040275

APA

Kremnev, N. S., Bryzgunov, M. I., Bubley, A. V., Parkhomchuk, V. V., Panasyuk, V. M., Reva, V. B., Putmakov, A. A., Pospolita, S. P., & Shiyankov, S. V. (2020). Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider. Physics of Particles and Nuclei Letters, 17(4), 438-442. https://doi.org/10.1134/S1547477120040275

Vancouver

Kremnev NS, Bryzgunov MI, Bubley AV, Parkhomchuk VV, Panasyuk VM, Reva VB и др. Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider. Physics of Particles and Nuclei Letters. 2020 июль 1;17(4):438-442. doi: 10.1134/S1547477120040275

Author

Kremnev, N. S. ; Bryzgunov, M. I. ; Bubley, A. V. и др. / Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider. в: Physics of Particles and Nuclei Letters. 2020 ; Том 17, № 4. стр. 438-442.

BibTeX

@article{6b01302acfaa409497b1756881b1d289,
title = "Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider",
abstract = "The HV electron cooling system designed at the Budker Institute of Nuclear Physics for the NICA collider is the world{\textquoteright}s only setup developed for a collider and makes it possible to simultaneously cool two ion beams with an energy up to 4.5 GeV/u using the magnetized electron flow [1]. Due to the fact that the cooling system should be installed at the NICA collider, the distance between the beam axes of cooling channels corresponds to the distance between collider beams and amounts to 320 mm. This became the first factor affecting the entire structure of the electron-cooling system and limits the maximum possible outer radius of longitudinal field coils. The energy-consumption limitation of 500–700 kW [2] can be considered the other factor, and it directly affects the density of filling the solenoid with the conductor. The design of the central solenoid (cooling solenoid) of the electron-cooling system is described, and it has been developed taking into account the imposed limitations.",
author = "Kremnev, {N. S.} and Bryzgunov, {M. I.} and Bubley, {A. V.} and Parkhomchuk, {V. V.} and Panasyuk, {V. M.} and Reva, {V. B.} and Putmakov, {A. A.} and Pospolita, {S. P.} and Shiyankov, {S. V.}",
year = "2020",
month = jul,
day = "1",
doi = "10.1134/S1547477120040275",
language = "English",
volume = "17",
pages = "438--442",
journal = "Physics of Particles and Nuclei Letters",
issn = "1547-4771",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "4",

}

RIS

TY - JOUR

T1 - Design of the Central Solenoid of the HV Electron Cooling System for the NICA Collider

AU - Kremnev, N. S.

AU - Bryzgunov, M. I.

AU - Bubley, A. V.

AU - Parkhomchuk, V. V.

AU - Panasyuk, V. M.

AU - Reva, V. B.

AU - Putmakov, A. A.

AU - Pospolita, S. P.

AU - Shiyankov, S. V.

PY - 2020/7/1

Y1 - 2020/7/1

N2 - The HV electron cooling system designed at the Budker Institute of Nuclear Physics for the NICA collider is the world’s only setup developed for a collider and makes it possible to simultaneously cool two ion beams with an energy up to 4.5 GeV/u using the magnetized electron flow [1]. Due to the fact that the cooling system should be installed at the NICA collider, the distance between the beam axes of cooling channels corresponds to the distance between collider beams and amounts to 320 mm. This became the first factor affecting the entire structure of the electron-cooling system and limits the maximum possible outer radius of longitudinal field coils. The energy-consumption limitation of 500–700 kW [2] can be considered the other factor, and it directly affects the density of filling the solenoid with the conductor. The design of the central solenoid (cooling solenoid) of the electron-cooling system is described, and it has been developed taking into account the imposed limitations.

AB - The HV electron cooling system designed at the Budker Institute of Nuclear Physics for the NICA collider is the world’s only setup developed for a collider and makes it possible to simultaneously cool two ion beams with an energy up to 4.5 GeV/u using the magnetized electron flow [1]. Due to the fact that the cooling system should be installed at the NICA collider, the distance between the beam axes of cooling channels corresponds to the distance between collider beams and amounts to 320 mm. This became the first factor affecting the entire structure of the electron-cooling system and limits the maximum possible outer radius of longitudinal field coils. The energy-consumption limitation of 500–700 kW [2] can be considered the other factor, and it directly affects the density of filling the solenoid with the conductor. The design of the central solenoid (cooling solenoid) of the electron-cooling system is described, and it has been developed taking into account the imposed limitations.

UR - http://www.scopus.com/inward/record.url?scp=85088633064&partnerID=8YFLogxK

U2 - 10.1134/S1547477120040275

DO - 10.1134/S1547477120040275

M3 - Article

AN - SCOPUS:85088633064

VL - 17

SP - 438

EP - 442

JO - Physics of Particles and Nuclei Letters

JF - Physics of Particles and Nuclei Letters

SN - 1547-4771

IS - 4

ER -

ID: 24830760