Standard

Current and voltage source induced polarization transients: a comparative consideration. / Kozhevnikov, N. O.; Antonov, E. Y.

в: Geophysical Prospecting, Том 66, № 2, 01.02.2018, стр. 422-431.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Kozhevnikov NO, Antonov EY. Current and voltage source induced polarization transients: a comparative consideration. Geophysical Prospecting. 2018 февр. 1;66(2):422-431. doi: 10.1111/1365-2478.12521

Author

Kozhevnikov, N. O. ; Antonov, E. Y. / Current and voltage source induced polarization transients: a comparative consideration. в: Geophysical Prospecting. 2018 ; Том 66, № 2. стр. 422-431.

BibTeX

@article{3d5ae7855b494a6e8b4f88f0787eba27,
title = "Current and voltage source induced polarization transients: a comparative consideration",
abstract = "The article discusses the excitation of transient induced polarization responses using current and voltage sources. The first method has found a wide application in induced polarization surveys and—directly or indirectly—in the theory of the induced polarization method. Typically, rectangular current pulses are injected into the earth via grounding electrodes, and decaying induced polarization voltage is measured during the pauses between pulses. In this case, only the secondary field is recorded in the absence of the primary field, which is an important advantage of this method. On the other hand, since the current injected into the ground is fully controlled by the source, this method does not allow studying induced polarization by measuring the current in the transmitter line or associated magnetic field. When energising the earth with voltage pulses, the measured quantity is the transient induced polarization current. In principle, this method allows induced polarization studies to be done by recording the transmitter line current, the associated magnetic field, or its rate of change. The decay of current in a grounded transmitter line depends not only on the induced polarization of the earth but also on the polarization of the grounding electrodes. This problem does not occur when induced polarization transients in the earth are excited inductively. A grounded transmitter line is a mixed-type source; hence, for a purely inductive excitation of induced polarization transients, one should use an ungrounded loop, which is coupled to the earth solely by electromagnetic induction.",
keywords = "Cole-Cole model, Induced polarization, Transient response",
author = "Kozhevnikov, {N. O.} and Antonov, {E. Y.}",
year = "2018",
month = feb,
day = "1",
doi = "10.1111/1365-2478.12521",
language = "English",
volume = "66",
pages = "422--431",
journal = "Geophysical Prospecting",
issn = "0016-8025",
publisher = "Wiley-Blackwell",
number = "2",

}

RIS

TY - JOUR

T1 - Current and voltage source induced polarization transients: a comparative consideration

AU - Kozhevnikov, N. O.

AU - Antonov, E. Y.

PY - 2018/2/1

Y1 - 2018/2/1

N2 - The article discusses the excitation of transient induced polarization responses using current and voltage sources. The first method has found a wide application in induced polarization surveys and—directly or indirectly—in the theory of the induced polarization method. Typically, rectangular current pulses are injected into the earth via grounding electrodes, and decaying induced polarization voltage is measured during the pauses between pulses. In this case, only the secondary field is recorded in the absence of the primary field, which is an important advantage of this method. On the other hand, since the current injected into the ground is fully controlled by the source, this method does not allow studying induced polarization by measuring the current in the transmitter line or associated magnetic field. When energising the earth with voltage pulses, the measured quantity is the transient induced polarization current. In principle, this method allows induced polarization studies to be done by recording the transmitter line current, the associated magnetic field, or its rate of change. The decay of current in a grounded transmitter line depends not only on the induced polarization of the earth but also on the polarization of the grounding electrodes. This problem does not occur when induced polarization transients in the earth are excited inductively. A grounded transmitter line is a mixed-type source; hence, for a purely inductive excitation of induced polarization transients, one should use an ungrounded loop, which is coupled to the earth solely by electromagnetic induction.

AB - The article discusses the excitation of transient induced polarization responses using current and voltage sources. The first method has found a wide application in induced polarization surveys and—directly or indirectly—in the theory of the induced polarization method. Typically, rectangular current pulses are injected into the earth via grounding electrodes, and decaying induced polarization voltage is measured during the pauses between pulses. In this case, only the secondary field is recorded in the absence of the primary field, which is an important advantage of this method. On the other hand, since the current injected into the ground is fully controlled by the source, this method does not allow studying induced polarization by measuring the current in the transmitter line or associated magnetic field. When energising the earth with voltage pulses, the measured quantity is the transient induced polarization current. In principle, this method allows induced polarization studies to be done by recording the transmitter line current, the associated magnetic field, or its rate of change. The decay of current in a grounded transmitter line depends not only on the induced polarization of the earth but also on the polarization of the grounding electrodes. This problem does not occur when induced polarization transients in the earth are excited inductively. A grounded transmitter line is a mixed-type source; hence, for a purely inductive excitation of induced polarization transients, one should use an ungrounded loop, which is coupled to the earth solely by electromagnetic induction.

KW - Cole-Cole model

KW - Induced polarization

KW - Transient response

UR - http://www.scopus.com/inward/record.url?scp=85018959773&partnerID=8YFLogxK

U2 - 10.1111/1365-2478.12521

DO - 10.1111/1365-2478.12521

M3 - Article

AN - SCOPUS:85018959773

VL - 66

SP - 422

EP - 431

JO - Geophysical Prospecting

JF - Geophysical Prospecting

SN - 0016-8025

IS - 2

ER -

ID: 9263496