Результаты исследований: Научные публикации в периодических изданиях › комментарий, выступление › Рецензирование
Corrigendum : Composite laser-pulses spectroscopy for high-accuracy optical clocks: A review of recent progress and perspectives (Reports on Progress in Physics (2018) 81 (094401) DOI: 10.1088/1361-6633/aac9e9). / Zanon-Willette, Thomas; Lefevre, Rémi; Metzdorff, Rémi и др.
в: Reports on Progress in Physics, Том 81, № 12, 129501, 29.10.2018.Результаты исследований: Научные публикации в периодических изданиях › комментарий, выступление › Рецензирование
}
TY - JOUR
T1 - Corrigendum
T2 - Composite laser-pulses spectroscopy for high-accuracy optical clocks: A review of recent progress and perspectives (Reports on Progress in Physics (2018) 81 (094401) DOI: 10.1088/1361-6633/aac9e9)
AU - Zanon-Willette, Thomas
AU - Lefevre, Rémi
AU - Metzdorff, Rémi
AU - Sillitoe, Nicolas
AU - Almonacil, Sylvain
AU - Minissale, Marco
AU - De Clercq, Emeric
AU - Taichenachev, Alexey V.
AU - Yudin, Valeriy I.
AU - Arimondo, Ennio
PY - 2018/10/29
Y1 - 2018/10/29
N2 - There are a few mistakes in this paper. One figure, one equation and three references have to be corrected. The figure 10(e) of section 3.3 was inadvertently replaced by figure 10(c). The correct figure 10(e) is the following: In appendix C two minus signs are missing in equation (C.6c). The corrected equation is: (Formula Presented). (Figure Presented). The correct writing of [91-93] is the following: 91] Yudin V I, Taichenachev A V, Basalaev M Y, Zanon-Willette T, Pollock J W, Shuker M, Donley E A and Kitching J 2018 Generalized auto-balanced Ramsey spectroscopy Phys. Rev. Appl. 9 054034 [92] Abdel Hafiz M, Coget M, Petersen M, Rocher C, Zanon-Willette T, Guerandel S, de Clercq E and Boudot R 2018 Toward a high-stability coherent population trapping Cs vapor-cell atomic clock using autobalanced Ramsey spectroscopy Phys. Rev. Appl. 9 064002 [93] Abdel Hafiz M, Coget M, Petersen M, Calosso C E, Guerandel S, de Clercq E and Boudot R 2018 Symmetric autobalanced Ramsey interrogation for high-performance coherent population trapping vapor-cell atomic clock Appl. Phys. Lett. 112 244102.
AB - There are a few mistakes in this paper. One figure, one equation and three references have to be corrected. The figure 10(e) of section 3.3 was inadvertently replaced by figure 10(c). The correct figure 10(e) is the following: In appendix C two minus signs are missing in equation (C.6c). The corrected equation is: (Formula Presented). (Figure Presented). The correct writing of [91-93] is the following: 91] Yudin V I, Taichenachev A V, Basalaev M Y, Zanon-Willette T, Pollock J W, Shuker M, Donley E A and Kitching J 2018 Generalized auto-balanced Ramsey spectroscopy Phys. Rev. Appl. 9 054034 [92] Abdel Hafiz M, Coget M, Petersen M, Rocher C, Zanon-Willette T, Guerandel S, de Clercq E and Boudot R 2018 Toward a high-stability coherent population trapping Cs vapor-cell atomic clock using autobalanced Ramsey spectroscopy Phys. Rev. Appl. 9 064002 [93] Abdel Hafiz M, Coget M, Petersen M, Calosso C E, Guerandel S, de Clercq E and Boudot R 2018 Symmetric autobalanced Ramsey interrogation for high-performance coherent population trapping vapor-cell atomic clock Appl. Phys. Lett. 112 244102.
UR - http://www.scopus.com/inward/record.url?scp=85056825249&partnerID=8YFLogxK
U2 - 10.1088/1361-6633/aae6b2
DO - 10.1088/1361-6633/aae6b2
M3 - Comment/debate
AN - SCOPUS:85056825249
VL - 81
JO - Reports on Progress in Physics
JF - Reports on Progress in Physics
SN - 0034-4885
IS - 12
M1 - 129501
ER -
ID: 17514803