Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
Continuous Glucose Monitoring Data Analysis in Insulin-Treated Type 1 and Type 2 Diabetic Subjects with the Use of Original Software. / Myakina, Natalia E.; Lots, Igor A.; Klimontov, Vadim V.
11th International Conference Bioinformatics of Genome Regulation and Structure\Systems Biology, BGRS\SB 2018 - Proceedings. Institute of Electrical and Electronics Engineers Inc., 2018. стр. 24-27 8544878.Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
}
TY - GEN
T1 - Continuous Glucose Monitoring Data Analysis in Insulin-Treated Type 1 and Type 2 Diabetic Subjects with the Use of Original Software
AU - Myakina, Natalia E.
AU - Lots, Igor A.
AU - Klimontov, Vadim V.
PY - 2018/11/26
Y1 - 2018/11/26
N2 - The aim: to compare glucose variability (GV) parameters derived from continuous glucose monitoring (CGM) in daytime and nocturnal hours in insulin-treated subjects with type 1 and type 2 diabetes.Materials and Methods: The CGM data from 130 type 1 diabetic and 117 type 2 diabetic patients were analyzed. The original software Sakharok was applied for time in range analysis. The GV parameters: Mean Amplitude of Glucose Excursions (MAGE), Lability Index (LI), Low Blood Glucose Index (LBGI), High Blood Glucose Index (HBGI), Continuous Overlapping Net Glycemic Action (CONGA), and Mean Absolute Glucose (MAG) were calculated with EasyGV software.Results: Patients with type 1 diabetes, as compared to those with type 2 diabetes, had higher mean 24-hour GV parameters: MAGE (p=0.000002), LI (p<0.00001), LBGI (p<0.00001), HBGI (p=0.008) and MAG (p=0.0002). Nocturnal MAGE, LI, MAG, HBGI, CONGA and time in hyperglycemic range were also higher in patients with type 1 diabetes (all p<0.02). Nocturnal LBGI and the prevalence of hypoglycemia were similar in both groups. In day-time hours type 1 diabetic subjects, as compare to those with type 2 diabetes, demonstrate lower CONGA (p=0.04) and higher prevalence of hypoglycemic episodes (p=0.000004).Conclusion: Insulin-treated patients with type 1 diabetes, as compared to type 2 diabetic subjects, have greater 24- hour CGM-derived GV parameters with more pronounced glucose fluctuations in the hyperglycemic range at night and more prevalent episodes of hypoglycemia in the daytime.
AB - The aim: to compare glucose variability (GV) parameters derived from continuous glucose monitoring (CGM) in daytime and nocturnal hours in insulin-treated subjects with type 1 and type 2 diabetes.Materials and Methods: The CGM data from 130 type 1 diabetic and 117 type 2 diabetic patients were analyzed. The original software Sakharok was applied for time in range analysis. The GV parameters: Mean Amplitude of Glucose Excursions (MAGE), Lability Index (LI), Low Blood Glucose Index (LBGI), High Blood Glucose Index (HBGI), Continuous Overlapping Net Glycemic Action (CONGA), and Mean Absolute Glucose (MAG) were calculated with EasyGV software.Results: Patients with type 1 diabetes, as compared to those with type 2 diabetes, had higher mean 24-hour GV parameters: MAGE (p=0.000002), LI (p<0.00001), LBGI (p<0.00001), HBGI (p=0.008) and MAG (p=0.0002). Nocturnal MAGE, LI, MAG, HBGI, CONGA and time in hyperglycemic range were also higher in patients with type 1 diabetes (all p<0.02). Nocturnal LBGI and the prevalence of hypoglycemia were similar in both groups. In day-time hours type 1 diabetic subjects, as compare to those with type 2 diabetes, demonstrate lower CONGA (p=0.04) and higher prevalence of hypoglycemic episodes (p=0.000004).Conclusion: Insulin-treated patients with type 1 diabetes, as compared to type 2 diabetic subjects, have greater 24- hour CGM-derived GV parameters with more pronounced glucose fluctuations in the hyperglycemic range at night and more prevalent episodes of hypoglycemia in the daytime.
UR - http://www.scopus.com/inward/record.url?scp=85059757298&partnerID=8YFLogxK
U2 - 10.1109/CSGB.2018.8544878
DO - 10.1109/CSGB.2018.8544878
M3 - Conference contribution
AN - SCOPUS:85059757298
SP - 24
EP - 27
BT - 11th International Conference Bioinformatics of Genome Regulation and Structure\Systems Biology, BGRS\SB 2018 - Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 11th International Conference Bioinformatics of Genome Regulation and Structure\Systems Biology, BGRS\SB 2018
Y2 - 20 August 2018 through 25 August 2018
ER -
ID: 18118984