title = "Comprehensive Review of Microfluidic Devices for Prostate-Specific Antigen Detection: From μPADs to Advanced Pump-Free Systems",
abstract = "Prostate cancer (PCa) remains one of the most common malignancies, and early diagnosis critically depends on accurate detection of prostate‑specific antigen (PSA). While conventional laboratory methods like ELISA offer high sensitivity, they are time‑consuming and require centralized infrastructure, limiting point‑of‑care (POC) use. This review focuses on passive capillary flow microfluidic platforms (LFIAs, μPADs, and hybrid systems) that rely on capillary, gravity, vacuum or slug‑flow for fluid transport. Active microfluidic devices (pump‑based) and standalone sensors are excluded due to their complexity and limited POC compatibility. We systematically evaluate these platforms in terms of materials, fabrication, detection methods, and their alignment with the REASSURED criteria for POC diagnostics. A weighted analysis shows that LFIAs excel in speed and simplicity but suffer from insufficient sensitivity. μPADs offer design flexibility and multiplexing but face challenges in reproducibility and integration. Hybrid pump‑free devices achieve the best overall balance, combining sensitivity comparable to ELISA with the simplicity required for POC use. The article critically discusses technological barriers to the implementation of research results: the lack of an integrated plasma separation system, insufficient stability of reagents, and the difficulty of interpreting multiparameter data. Future directions highlight machine‑learning‑based risk prediction, digital twins for personalized diagnostics, and the translation of prototypes into commercial products. This review provides a roadmap for implementing pump‑free microfluidic PSA testing in real‑world settings.",
keywords = "Immunoassay, Lateral-flow, Microfluidic, POC, PSA, Paper-based",
author = "Kseniya Miniailo and Anzhelika Martynenko and Lomova Mariia and Petkov Andrei",
note = "This research was supported by the Ministry of Science and Higher Education of the Russian Federation under the strategic academic leadership program “Priority 2030” at NSU.",
year = "2026",
month = jun,
day = "17",
doi = "10.1007/s44174-026-00726-w",
language = "English",
journal = "Biomedical Materials and Devices",
issn = "2731-4812",
publisher = "Springer Nature",

}

RIS

TY - JOUR

T1 - Comprehensive Review of Microfluidic Devices for Prostate-Specific Antigen Detection: From μPADs to Advanced Pump-Free Systems

AU - Miniailo, Kseniya

AU - Martynenko, Anzhelika

AU - Mariia, Lomova

AU - Andrei, Petkov

N1 - This research was supported by the Ministry of Science and Higher Education of the Russian Federation under the strategic academic leadership program “Priority 2030” at NSU.

PY - 2026/6/17

Y1 - 2026/6/17

N2 - Prostate cancer (PCa) remains one of the most common malignancies, and early diagnosis critically depends on accurate detection of prostate‑specific antigen (PSA). While conventional laboratory methods like ELISA offer high sensitivity, they are time‑consuming and require centralized infrastructure, limiting point‑of‑care (POC) use. This review focuses on passive capillary flow microfluidic platforms (LFIAs, μPADs, and hybrid systems) that rely on capillary, gravity, vacuum or slug‑flow for fluid transport. Active microfluidic devices (pump‑based) and standalone sensors are excluded due to their complexity and limited POC compatibility. We systematically evaluate these platforms in terms of materials, fabrication, detection methods, and their alignment with the REASSURED criteria for POC diagnostics. A weighted analysis shows that LFIAs excel in speed and simplicity but suffer from insufficient sensitivity. μPADs offer design flexibility and multiplexing but face challenges in reproducibility and integration. Hybrid pump‑free devices achieve the best overall balance, combining sensitivity comparable to ELISA with the simplicity required for POC use. The article critically discusses technological barriers to the implementation of research results: the lack of an integrated plasma separation system, insufficient stability of reagents, and the difficulty of interpreting multiparameter data. Future directions highlight machine‑learning‑based risk prediction, digital twins for personalized diagnostics, and the translation of prototypes into commercial products. This review provides a roadmap for implementing pump‑free microfluidic PSA testing in real‑world settings.

AB - Prostate cancer (PCa) remains one of the most common malignancies, and early diagnosis critically depends on accurate detection of prostate‑specific antigen (PSA). While conventional laboratory methods like ELISA offer high sensitivity, they are time‑consuming and require centralized infrastructure, limiting point‑of‑care (POC) use. This review focuses on passive capillary flow microfluidic platforms (LFIAs, μPADs, and hybrid systems) that rely on capillary, gravity, vacuum or slug‑flow for fluid transport. Active microfluidic devices (pump‑based) and standalone sensors are excluded due to their complexity and limited POC compatibility. We systematically evaluate these platforms in terms of materials, fabrication, detection methods, and their alignment with the REASSURED criteria for POC diagnostics. A weighted analysis shows that LFIAs excel in speed and simplicity but suffer from insufficient sensitivity. μPADs offer design flexibility and multiplexing but face challenges in reproducibility and integration. Hybrid pump‑free devices achieve the best overall balance, combining sensitivity comparable to ELISA with the simplicity required for POC use. The article critically discusses technological barriers to the implementation of research results: the lack of an integrated plasma separation system, insufficient stability of reagents, and the difficulty of interpreting multiparameter data. Future directions highlight machine‑learning‑based risk prediction, digital twins for personalized diagnostics, and the translation of prototypes into commercial products. This review provides a roadmap for implementing pump‑free microfluidic PSA testing in real‑world settings.

KW - Immunoassay

KW - Lateral-flow

KW - Microfluidic

KW - POC

KW - PSA

KW - Paper-based

UR - https://www.scopus.com/pages/publications/105042107723