Standard

Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy. / Boldyreva, Lidiya V.; Kharenko, Denis S.; Serebrennikov, Kirill V. и др.

в: Diagnostics, Том 16, № 3, 438, 01.02.2026.

Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование

Harvard

APA

Vancouver

Boldyreva LV, Kharenko DS, Serebrennikov KV, Evtushenko AA, Shloma VV, Radnatarov DA и др. Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy. Diagnostics. 2026 февр. 1;16(3):438. doi: 10.3390/diagnostics16030438

Author

BibTeX

@article{27fc34e31a374352b03f5feb4a8bc622,
title = "Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy",
abstract = "Multiphoton endomicroscopy (MPEM) has recently become a key development in optical biomedical diagnostics, providing histologically relevant in vivo images that are eliminating both the need for tissue damage during biopsy sampling and the need for dye injections. Due to its ability to visualize structures at the epithelial, extracellular matrix, and subcellular levels, MPEM offers a promising diagnostic method for precancerous conditions and early forms of gastrointestinal (GI) cancer. The high specificity of multiphoton signals—the two-photon fluorescence response of endogenous fluorophores (NADH, FAD), the second-harmonic generation signal from collagen, and others—makes this method a promising alternative to both traditional histology and confocal endoscopy, enabling real-time assessment of metabolic status, intestinal epithelial cell status, and stromal remodeling. Despite the promising prospects of multiphoton microscopy, its practical implementation is progressing extremely slowly. The main factors here include the difficulty of delivering ultrashort pulses with high peak power, which is necessary for multiphoton excitation (MPE), and obtaining these pulses at the required wavelengths to activate the autofluorescence mechanism. One of the most promising solutions is the use of specialized multimode optical fibers that can both induce beam self-cleaning (BSC), which allows for the formation of a stable beam profile close to the fundamental mode, and significantly broaden the optical spectrum, which can ultimately cover the entire region of interest. This review presents the biophysical foundations of multiphoton microscopy of GI tissue, existing endoscopic architectures for MPE, and an analysis of the potential for using novel nonlinear effects in multimode optical fibers, such as the BSC effect and supercontinuum generation. It is concluded that the use of optical fibers in which the listed effects are realized in the tracts of multiphoton endomicroscopes can become a key step in the creation of a new generation of high-resolution instruments for the early detection of malignant neoplasms of the GI tract.",
keywords = "artificial intelligence, colorectal cancer, inflammatory bowel disease, multimode fibers, multiphoton endomicroscopy, nonlinear imaging, numerical simulations, воспалительные заболевания кишечника, колоректальный рак, нелинейная визуализация, многофотонная эндомикроскопия;, многомодовые оптические волокна, численное моделирование, искусственный интеллект",
author = "Boldyreva, {Lidiya V.} and Kharenko, {Denis S.} and Serebrennikov, {Kirill V.} and Evtushenko, {Anna A.} and Shloma, {Viktor V.} and Radnatarov, {Daba A.} and Dostovalov, {Alexandr V.} and Munkueva, {Zhibzema E.} and Sidelnikov, {Oleg S.} and Chekhovskoy, {Igor S.} and Raspopin, {Kirill S.} and Gervaziev, {Mikhail D.} and Stefan Wabnitz",
note = "Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy / L. V. Boldyreva, D. S. Kharenko, K. V. Serebrennikov [et al.] // Diagnostics. – 2026. – Vol. 16, No. 3. – P. 438. – DOI 10.3390/diagnostics16030438. – EDN AXXHJY. This research was funded by Russian Science Foundation (RSF) grant number 25-72-31018.",
year = "2026",
month = feb,
day = "1",
doi = "10.3390/diagnostics16030438",
language = "English",
volume = "16",
journal = "Diagnostics",
issn = "2075-4418",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "3",

}

RIS

TY - JOUR

T1 - Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy

AU - Boldyreva, Lidiya V.

AU - Kharenko, Denis S.

AU - Serebrennikov, Kirill V.

AU - Evtushenko, Anna A.

AU - Shloma, Viktor V.

AU - Radnatarov, Daba A.

AU - Dostovalov, Alexandr V.

AU - Munkueva, Zhibzema E.

AU - Sidelnikov, Oleg S.

AU - Chekhovskoy, Igor S.

AU - Raspopin, Kirill S.

AU - Gervaziev, Mikhail D.

AU - Wabnitz, Stefan

N1 - Challenges and Prospects of Using Novel Nonlinear Effects in Multimode Optical Fibers for Multiphoton Endomicroscopy / L. V. Boldyreva, D. S. Kharenko, K. V. Serebrennikov [et al.] // Diagnostics. – 2026. – Vol. 16, No. 3. – P. 438. – DOI 10.3390/diagnostics16030438. – EDN AXXHJY. This research was funded by Russian Science Foundation (RSF) grant number 25-72-31018.

PY - 2026/2/1

Y1 - 2026/2/1

N2 - Multiphoton endomicroscopy (MPEM) has recently become a key development in optical biomedical diagnostics, providing histologically relevant in vivo images that are eliminating both the need for tissue damage during biopsy sampling and the need for dye injections. Due to its ability to visualize structures at the epithelial, extracellular matrix, and subcellular levels, MPEM offers a promising diagnostic method for precancerous conditions and early forms of gastrointestinal (GI) cancer. The high specificity of multiphoton signals—the two-photon fluorescence response of endogenous fluorophores (NADH, FAD), the second-harmonic generation signal from collagen, and others—makes this method a promising alternative to both traditional histology and confocal endoscopy, enabling real-time assessment of metabolic status, intestinal epithelial cell status, and stromal remodeling. Despite the promising prospects of multiphoton microscopy, its practical implementation is progressing extremely slowly. The main factors here include the difficulty of delivering ultrashort pulses with high peak power, which is necessary for multiphoton excitation (MPE), and obtaining these pulses at the required wavelengths to activate the autofluorescence mechanism. One of the most promising solutions is the use of specialized multimode optical fibers that can both induce beam self-cleaning (BSC), which allows for the formation of a stable beam profile close to the fundamental mode, and significantly broaden the optical spectrum, which can ultimately cover the entire region of interest. This review presents the biophysical foundations of multiphoton microscopy of GI tissue, existing endoscopic architectures for MPE, and an analysis of the potential for using novel nonlinear effects in multimode optical fibers, such as the BSC effect and supercontinuum generation. It is concluded that the use of optical fibers in which the listed effects are realized in the tracts of multiphoton endomicroscopes can become a key step in the creation of a new generation of high-resolution instruments for the early detection of malignant neoplasms of the GI tract.

AB - Multiphoton endomicroscopy (MPEM) has recently become a key development in optical biomedical diagnostics, providing histologically relevant in vivo images that are eliminating both the need for tissue damage during biopsy sampling and the need for dye injections. Due to its ability to visualize structures at the epithelial, extracellular matrix, and subcellular levels, MPEM offers a promising diagnostic method for precancerous conditions and early forms of gastrointestinal (GI) cancer. The high specificity of multiphoton signals—the two-photon fluorescence response of endogenous fluorophores (NADH, FAD), the second-harmonic generation signal from collagen, and others—makes this method a promising alternative to both traditional histology and confocal endoscopy, enabling real-time assessment of metabolic status, intestinal epithelial cell status, and stromal remodeling. Despite the promising prospects of multiphoton microscopy, its practical implementation is progressing extremely slowly. The main factors here include the difficulty of delivering ultrashort pulses with high peak power, which is necessary for multiphoton excitation (MPE), and obtaining these pulses at the required wavelengths to activate the autofluorescence mechanism. One of the most promising solutions is the use of specialized multimode optical fibers that can both induce beam self-cleaning (BSC), which allows for the formation of a stable beam profile close to the fundamental mode, and significantly broaden the optical spectrum, which can ultimately cover the entire region of interest. This review presents the biophysical foundations of multiphoton microscopy of GI tissue, existing endoscopic architectures for MPE, and an analysis of the potential for using novel nonlinear effects in multimode optical fibers, such as the BSC effect and supercontinuum generation. It is concluded that the use of optical fibers in which the listed effects are realized in the tracts of multiphoton endomicroscopes can become a key step in the creation of a new generation of high-resolution instruments for the early detection of malignant neoplasms of the GI tract.

KW - artificial intelligence

KW - colorectal cancer

KW - inflammatory bowel disease

KW - multimode fibers

KW - multiphoton endomicroscopy

KW - nonlinear imaging

KW - numerical simulations

KW - воспалительные заболевания кишечника

KW - колоректальный рак

KW - нелинейная визуализация

KW - многофотонная эндомикроскопия;

KW - многомодовые оптические волокна

KW - численное моделирование

KW - искусственный интеллект

UR - https://www.mendeley.com/catalogue/1abb9d7d-8c7a-3195-8445-ba25c9b14eae/

UR - https://www.scopus.com/pages/publications/105029810773

UR - https://elibrary.ru/item.asp?id=90330865

U2 - 10.3390/diagnostics16030438

DO - 10.3390/diagnostics16030438

M3 - Article

C2 - 41681754

VL - 16

JO - Diagnostics

JF - Diagnostics

SN - 2075-4418

IS - 3

M1 - 438

ER -

ID: 85795845