Standard

BPM System for VEPP-4M Collider. / Bekhtenev, E. A.; Karpov, G. V.

в: Physics of Particles and Nuclei Letters, Том 15, № 7, 01.12.2018, стр. 929-932.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Bekhtenev, EA & Karpov, GV 2018, 'BPM System for VEPP-4M Collider', Physics of Particles and Nuclei Letters, Том. 15, № 7, стр. 929-932. https://doi.org/10.1134/S1547477118070154

APA

Bekhtenev, E. A., & Karpov, G. V. (2018). BPM System for VEPP-4M Collider. Physics of Particles and Nuclei Letters, 15(7), 929-932. https://doi.org/10.1134/S1547477118070154

Vancouver

Bekhtenev EA, Karpov GV. BPM System for VEPP-4M Collider. Physics of Particles and Nuclei Letters. 2018 дек. 1;15(7):929-932. doi: 10.1134/S1547477118070154

Author

Bekhtenev, E. A. ; Karpov, G. V. / BPM System for VEPP-4M Collider. в: Physics of Particles and Nuclei Letters. 2018 ; Том 15, № 7. стр. 929-932.

BibTeX

@article{d722906e0f094c24adc0201c0527e977,
title = "BPM System for VEPP-4M Collider",
abstract = "Developed in BINP wideband beam position monitor (BPM) electronics has been installed at the VEPP-4M electron-positron collider. The VEPP-4M operates with two electron and two positron bunches. Wide bandwidth of new electronics (200 MHz) allows the separate measurements of electron and positron bunches with time interval between bunches up to 18 ns. At present upgrade all 54 BPMs are supplied with new electronics. The electronics can measure the position of each of four bunches. BPM system works at two modes: slow closed orbit measurements and turn-by-turn measurements. We present details of system design and operation.",
author = "Bekhtenev, {E. A.} and Karpov, {G. V.}",
note = "Publisher Copyright: {\textcopyright} 2018, Pleiades Publishing, Ltd.",
year = "2018",
month = dec,
day = "1",
doi = "10.1134/S1547477118070154",
language = "English",
volume = "15",
pages = "929--932",
journal = "Physics of Particles and Nuclei Letters",
issn = "1547-4771",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "7",

}

RIS

TY - JOUR

T1 - BPM System for VEPP-4M Collider

AU - Bekhtenev, E. A.

AU - Karpov, G. V.

N1 - Publisher Copyright: © 2018, Pleiades Publishing, Ltd.

PY - 2018/12/1

Y1 - 2018/12/1

N2 - Developed in BINP wideband beam position monitor (BPM) electronics has been installed at the VEPP-4M electron-positron collider. The VEPP-4M operates with two electron and two positron bunches. Wide bandwidth of new electronics (200 MHz) allows the separate measurements of electron and positron bunches with time interval between bunches up to 18 ns. At present upgrade all 54 BPMs are supplied with new electronics. The electronics can measure the position of each of four bunches. BPM system works at two modes: slow closed orbit measurements and turn-by-turn measurements. We present details of system design and operation.

AB - Developed in BINP wideband beam position monitor (BPM) electronics has been installed at the VEPP-4M electron-positron collider. The VEPP-4M operates with two electron and two positron bunches. Wide bandwidth of new electronics (200 MHz) allows the separate measurements of electron and positron bunches with time interval between bunches up to 18 ns. At present upgrade all 54 BPMs are supplied with new electronics. The electronics can measure the position of each of four bunches. BPM system works at two modes: slow closed orbit measurements and turn-by-turn measurements. We present details of system design and operation.

UR - http://www.scopus.com/inward/record.url?scp=85058928737&partnerID=8YFLogxK

U2 - 10.1134/S1547477118070154

DO - 10.1134/S1547477118070154

M3 - Article

AN - SCOPUS:85058928737

VL - 15

SP - 929

EP - 932

JO - Physics of Particles and Nuclei Letters

JF - Physics of Particles and Nuclei Letters

SN - 1547-4771

IS - 7

ER -

ID: 18073034