Standard

Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators. / Erushin, E. Yu; Kostyukova, N. Yu; Boyko, A. A. и др.

в: Instruments and Experimental Techniques, Том 67, № 3, 2024, стр. 505-510.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Erushin, EY, Kostyukova, NY, Boyko, AA & Miroshnichenko, IB 2024, 'Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators', Instruments and Experimental Techniques, Том. 67, № 3, стр. 505-510. https://doi.org/10.1134/S0020441224700738

APA

Erushin, E. Y., Kostyukova, N. Y., Boyko, A. A., & Miroshnichenko, I. B. (2024). Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators. Instruments and Experimental Techniques, 67(3), 505-510. https://doi.org/10.1134/S0020441224700738

Vancouver

Erushin EY, Kostyukova NY, Boyko AA, Miroshnichenko IB. Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators. Instruments and Experimental Techniques. 2024;67(3):505-510. doi: 10.1134/S0020441224700738

Author

Erushin, E. Yu ; Kostyukova, N. Yu ; Boyko, A. A. и др. / Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators. в: Instruments and Experimental Techniques. 2024 ; Том 67, № 3. стр. 505-510.

BibTeX

@article{6f74934160a642858c081d763db6f8df,
title = "Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators",
abstract = " The multicomponent gas analyzer has a wide range of applications, such as environmental monitoring, chemical reaction and industrial process control, accident prevention, exploration in the oil and gas industries, and biomedicine. Laser photoacoustic spectroscopy is the universal method for analyzing gaseous impurities due to its high selectivity, sensitivity, and fast response. This paper presents an automated gas analysis system based on the combined optical parametric oscillators tuning from 2.5 to 10.8 µm. The full width at half maximum of the spectral line is approximately 5.5 ± 0.5 cm–1 in the range from 2.5 to 4.5 μm and approximately 2 ± 0.5 cm–1 in the range from 4.5 to 10.8 μm. Using software installed on the control computer, the controller performs all necessary operations, including pumping, analysis, and removal of gas samples in the measuring complex. The paper presents experimentally recorded absorption spectra of gas mixtures of CO, CO2, and CH4 obtained using a differential photoacoustic detector.",
author = "Erushin, {E. Yu} and Kostyukova, {N. Yu} and Boyko, {A. A.} and Miroshnichenko, {I. B.}",
note = "This work was supported by the Russian Science Foundation (grant no. 17-72-30006-P).",
year = "2024",
doi = "10.1134/S0020441224700738",
language = "English",
volume = "67",
pages = "505--510",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "3",

}

RIS

TY - JOUR

T1 - Automated System for Detecting Atmospheric Gases CO, CO2, and CH4 Based on Optical Parametric Oscillators

AU - Erushin, E. Yu

AU - Kostyukova, N. Yu

AU - Boyko, A. A.

AU - Miroshnichenko, I. B.

N1 - This work was supported by the Russian Science Foundation (grant no. 17-72-30006-P).

PY - 2024

Y1 - 2024

N2 - The multicomponent gas analyzer has a wide range of applications, such as environmental monitoring, chemical reaction and industrial process control, accident prevention, exploration in the oil and gas industries, and biomedicine. Laser photoacoustic spectroscopy is the universal method for analyzing gaseous impurities due to its high selectivity, sensitivity, and fast response. This paper presents an automated gas analysis system based on the combined optical parametric oscillators tuning from 2.5 to 10.8 µm. The full width at half maximum of the spectral line is approximately 5.5 ± 0.5 cm–1 in the range from 2.5 to 4.5 μm and approximately 2 ± 0.5 cm–1 in the range from 4.5 to 10.8 μm. Using software installed on the control computer, the controller performs all necessary operations, including pumping, analysis, and removal of gas samples in the measuring complex. The paper presents experimentally recorded absorption spectra of gas mixtures of CO, CO2, and CH4 obtained using a differential photoacoustic detector.

AB - The multicomponent gas analyzer has a wide range of applications, such as environmental monitoring, chemical reaction and industrial process control, accident prevention, exploration in the oil and gas industries, and biomedicine. Laser photoacoustic spectroscopy is the universal method for analyzing gaseous impurities due to its high selectivity, sensitivity, and fast response. This paper presents an automated gas analysis system based on the combined optical parametric oscillators tuning from 2.5 to 10.8 µm. The full width at half maximum of the spectral line is approximately 5.5 ± 0.5 cm–1 in the range from 2.5 to 4.5 μm and approximately 2 ± 0.5 cm–1 in the range from 4.5 to 10.8 μm. Using software installed on the control computer, the controller performs all necessary operations, including pumping, analysis, and removal of gas samples in the measuring complex. The paper presents experimentally recorded absorption spectra of gas mixtures of CO, CO2, and CH4 obtained using a differential photoacoustic detector.

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85207463025&origin=inward&txGid=cdb179392d4bd83e742422c33a690430

UR - https://www.mendeley.com/catalogue/5bfd4ceb-2e5f-3fa6-b05f-cc95a55c7dfb/

U2 - 10.1134/S0020441224700738

DO - 10.1134/S0020441224700738

M3 - Article

VL - 67

SP - 505

EP - 510

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 3

ER -

ID: 60864470