Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
Application of saturable absorption adaptive visualizing transparencies to obtain flow density fields. / Pavlov, A. A.; Shevchenko, A. M.; Shmakov, A. S. и др.
Proceedings of the XXV Conference on High-Energy Processes in Condensed Matter, HEPCM 2017: Dedicated to the 60th Anniversary of the Khristianovich Institute of Theoretical and Applied Mechanics SB RAS. ред. / Fomin. Том 1893 American Institute of Physics Inc., 2017. 030079 (AIP Conference Proceedings; Том 1893).Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференций › статья в сборнике материалов конференции › научная › Рецензирование
}
TY - GEN
T1 - Application of saturable absorption adaptive visualizing transparencies to obtain flow density fields
AU - Pavlov, A. A.
AU - Shevchenko, A. M.
AU - Shmakov, A. S.
AU - Pavlov, A. A.
PY - 2017/10/26
Y1 - 2017/10/26
N2 - In the present work a variation of schlieren technique increasing its sensitivity and usability is described. New self-adjustable adaptive transparencies (cutoffs) based on bleaching effect are suggested. The transparencies are thin layers made of translucent substance which are placed in the focal plane of the receiving lens of a shlieren system. To implement the technique laser light sources have to be used. It was shown the transparencies have low response time (10-20 μs) allowing significantly reduce liability of the system to vibrations. Such adaptive visualizing transparencies (AVT) have an increased sensitivity and usability and enable one to obtain a quantitative data.
AB - In the present work a variation of schlieren technique increasing its sensitivity and usability is described. New self-adjustable adaptive transparencies (cutoffs) based on bleaching effect are suggested. The transparencies are thin layers made of translucent substance which are placed in the focal plane of the receiving lens of a shlieren system. To implement the technique laser light sources have to be used. It was shown the transparencies have low response time (10-20 μs) allowing significantly reduce liability of the system to vibrations. Such adaptive visualizing transparencies (AVT) have an increased sensitivity and usability and enable one to obtain a quantitative data.
UR - http://www.scopus.com/inward/record.url?scp=85034224219&partnerID=8YFLogxK
U2 - 10.1063/1.5007537
DO - 10.1063/1.5007537
M3 - Conference contribution
AN - SCOPUS:85034224219
VL - 1893
T3 - AIP Conference Proceedings
BT - Proceedings of the XXV Conference on High-Energy Processes in Condensed Matter, HEPCM 2017
A2 - Fomin, null
PB - American Institute of Physics Inc.
T2 - 25th Conference on High-Energy Processes in Condensed Matter, HEPCM 2017
Y2 - 5 June 2017 through 9 June 2017
ER -
ID: 9697556