Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
An Experimental Study of Heat Transfer at the Interface between Two Immiscible Liquids Using Two-Color PLIF Method. / Zotyeva, A. A.; Nichik, M. Yu.; Dulin, V. M.
в: Journal of Engineering Thermophysics, Том 35, № 1, 04.09.2026, стр. 81-90.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - An Experimental Study of Heat Transfer at the Interface between Two Immiscible Liquids Using Two-Color PLIF Method
AU - Zotyeva, A. A.
AU - Nichik, M. Yu.
AU - Dulin, V. M.
N1 - Zotyeva, A. A. An Experimental Study of Heat Transfer at the Interface between Two Immiscible Liquids Using Two-Color PLIF Method / A. A. Zotyeva, M. Yu. Nichik, V. M. Dulin // Journal of Engineering Thermophysics. – 2026. – Vol. 35, No. 1. – P. 81-90. – DOI 10.1134/S1810232826010091. – EDN EYUJWP. This research was supported by the Ministry of Science and Higher Education of the Russian Federation (grant 075-15-2025-007, https://megagrant.ru/labs/lab_rus_1082740/) (contributions by A. A. Zotyeva and M. Yu. Nichik) and the Russian Science Foundation (RSF) (grant 19-79-30075, https://rscf.ru/project/19-79-30075/) (contribution by V. M. Dulin, development of the calibration procedure). The equipment was provided under a state contract of IT SB RAS
PY - 2026/9/4
Y1 - 2026/9/4
N2 - This study aims to enhance the accuracy and reliability of temperature measurements in liquid films and droplets using an extended two-color/two-dye planar laser-induced fluorescence (2C/2D PLIF) method. The experiment employs Kiton Red (temperature-sensitive) and Rhodamine 6G (temperature-insensitive) dyes to compensate for concentration fluctuations and environmental effects. A calibrated setup with synchronized cameras, optical filters, and a pulsed laser is used to capture the fluorescence intensities of glycerol and oil emulsions. The key results demonstrate a successful reconstruction of the temperature fields with a spatial resolution of 138 pixels/mm and an RMS error below 5%, validated against thermocouple measurements. The most significant finding is that the method resolves thermal gradients in both stratified and mixed-phase systems, though optical distortions at the interfaces pose challenges. The major conclusion highlights the potential of the 2C/2D PLIF method for high-resolution, non-contact thermometry in combustion and heat transfer applications, future improvements being needed to address interfacial artifacts.
AB - This study aims to enhance the accuracy and reliability of temperature measurements in liquid films and droplets using an extended two-color/two-dye planar laser-induced fluorescence (2C/2D PLIF) method. The experiment employs Kiton Red (temperature-sensitive) and Rhodamine 6G (temperature-insensitive) dyes to compensate for concentration fluctuations and environmental effects. A calibrated setup with synchronized cameras, optical filters, and a pulsed laser is used to capture the fluorescence intensities of glycerol and oil emulsions. The key results demonstrate a successful reconstruction of the temperature fields with a spatial resolution of 138 pixels/mm and an RMS error below 5%, validated against thermocouple measurements. The most significant finding is that the method resolves thermal gradients in both stratified and mixed-phase systems, though optical distortions at the interfaces pose challenges. The major conclusion highlights the potential of the 2C/2D PLIF method for high-resolution, non-contact thermometry in combustion and heat transfer applications, future improvements being needed to address interfacial artifacts.
KW - 2C/2D PLIF
KW - Kiton Red
KW - Rhodamine 6G
KW - emulsions
KW - 2C/2D PLIF
KW - красный краситель Kiton
KW - Kiton Red
KW - родамин 6G
KW - эмульсии
UR - https://www.mendeley.com/catalogue/77fd64da-8475-36b3-ba39-17e0abbac4c5/
UR - https://www.scopus.com/pages/publications/105049298543
UR - https://elibrary.ru/item.asp?id=92019529
U2 - 10.1134/S1810232826010091
DO - 10.1134/S1810232826010091
M3 - Article
VL - 35
SP - 81
EP - 90
JO - Journal of Engineering Thermophysics
JF - Journal of Engineering Thermophysics
SN - 1810-2328
IS - 1
ER -
ID: 85119256