Standard

Active Control of the Precession Frequency of the Vortex Core Using Rotating Jets. / Suslov, Daniil; Skripkin, Sergey.

в: Energies, Том 19, № 3, 719, 29.01.2026.

Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{d4fe0d1d6961404eae4f6c4f3fc8183c,
title = "Active Control of the Precession Frequency of the Vortex Core Using Rotating Jets",
abstract = "The precessing vortex core (PVC) is a major source of low-frequency harmful pressure pulsations that constrain the stable operating range of Francis turbines under part-load regimes. This study presents an experimental demonstration of active frequency control for the PVC in an aerodynamic turbine model (at Reynolds number 1.5 × 104), employing a resonant forcing strategy grounded in linear stability theory. Low-energy air injection with a momentum flux coefficient in the range of approximately 0.06% to 1.56% was applied via rotating actuators positioned within the flow region of highest receptivity. The core finding is the observation of frequency, where the PVC{\textquoteright}s natural precession frequency synchronizes with that of the rotating actuator. A comparative analysis of actuator geometry revealed that a single-jet configuration achieves a significantly greater frequency shift, up to 22%, and a wider lock-in range than a dual-jet actuator (8% shift). This enhanced performance is attributed to the higher momentum flux density and more spatially coherent forcing generated by the single jet, which couples more effectively with the global instability mode. The results validate the successful adaptation of a highly efficient, physics-based control paradigm from reacting flows to hydraulic machinery, offering a promising approach to mitigate vortex-induced vibrations and expanding turbine operational flexibility.",
keywords = "Francis turbine, active flow control, frequency lock-in, precessing vortex core (PVC), swirling flows, vortex breakdown",
author = "Daniil Suslov and Sergey Skripkin",
note = "The study was supported by the Russian Science Foundation, Grant No. 25-79-30002 (https://rscf.ru/en/project/25-79-30002/, accessed on 28 January 2026). The experimental facilities were provided under a state contract with IT SB RAS.",
year = "2026",
month = jan,
day = "29",
doi = "10.3390/en19030719",
language = "English",
volume = "19",
journal = "Energies",
issn = "1996-1073",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "3",

}

RIS

TY - JOUR

T1 - Active Control of the Precession Frequency of the Vortex Core Using Rotating Jets

AU - Suslov, Daniil

AU - Skripkin, Sergey

N1 - The study was supported by the Russian Science Foundation, Grant No. 25-79-30002 (https://rscf.ru/en/project/25-79-30002/, accessed on 28 January 2026). The experimental facilities were provided under a state contract with IT SB RAS.

PY - 2026/1/29

Y1 - 2026/1/29

N2 - The precessing vortex core (PVC) is a major source of low-frequency harmful pressure pulsations that constrain the stable operating range of Francis turbines under part-load regimes. This study presents an experimental demonstration of active frequency control for the PVC in an aerodynamic turbine model (at Reynolds number 1.5 × 104), employing a resonant forcing strategy grounded in linear stability theory. Low-energy air injection with a momentum flux coefficient in the range of approximately 0.06% to 1.56% was applied via rotating actuators positioned within the flow region of highest receptivity. The core finding is the observation of frequency, where the PVC’s natural precession frequency synchronizes with that of the rotating actuator. A comparative analysis of actuator geometry revealed that a single-jet configuration achieves a significantly greater frequency shift, up to 22%, and a wider lock-in range than a dual-jet actuator (8% shift). This enhanced performance is attributed to the higher momentum flux density and more spatially coherent forcing generated by the single jet, which couples more effectively with the global instability mode. The results validate the successful adaptation of a highly efficient, physics-based control paradigm from reacting flows to hydraulic machinery, offering a promising approach to mitigate vortex-induced vibrations and expanding turbine operational flexibility.

AB - The precessing vortex core (PVC) is a major source of low-frequency harmful pressure pulsations that constrain the stable operating range of Francis turbines under part-load regimes. This study presents an experimental demonstration of active frequency control for the PVC in an aerodynamic turbine model (at Reynolds number 1.5 × 104), employing a resonant forcing strategy grounded in linear stability theory. Low-energy air injection with a momentum flux coefficient in the range of approximately 0.06% to 1.56% was applied via rotating actuators positioned within the flow region of highest receptivity. The core finding is the observation of frequency, where the PVC’s natural precession frequency synchronizes with that of the rotating actuator. A comparative analysis of actuator geometry revealed that a single-jet configuration achieves a significantly greater frequency shift, up to 22%, and a wider lock-in range than a dual-jet actuator (8% shift). This enhanced performance is attributed to the higher momentum flux density and more spatially coherent forcing generated by the single jet, which couples more effectively with the global instability mode. The results validate the successful adaptation of a highly efficient, physics-based control paradigm from reacting flows to hydraulic machinery, offering a promising approach to mitigate vortex-induced vibrations and expanding turbine operational flexibility.

KW - Francis turbine

KW - active flow control

KW - frequency lock-in

KW - precessing vortex core (PVC)

KW - swirling flows

KW - vortex breakdown

UR - https://www.scopus.com/pages/publications/105030018677

UR - https://www.mendeley.com/catalogue/6f817b03-d993-3d9b-ad5c-08502eee3a94/

U2 - 10.3390/en19030719

DO - 10.3390/en19030719

M3 - Article

VL - 19

JO - Energies

JF - Energies

SN - 1996-1073

IS - 3

M1 - 719

ER -