Standard

A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter. / Vitali, B.; Papa, A.; Baldini, A. M. и др.

в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 1049, 168020, 04.2023.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Vitali, B, Papa, A, Baldini, AM, Benmansour, H, Bianucci, S, Cei, F, Chiappini, M, Chiarello, G, Maso, GD, Francesconi, M, Galli, L, Grassi, M, Grigoriev, DN, Hildebrandt, M, Meuwly, M, Nicolò, D, Raffaelli, F, Schwendimann, P, Signorelli, G & Venturini, A 2023, 'A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 1049, 168020. https://doi.org/10.1016/j.nima.2023.168020

APA

Vitali, B., Papa, A., Baldini, A. M., Benmansour, H., Bianucci, S., Cei, F., Chiappini, M., Chiarello, G., Maso, G. D., Francesconi, M., Galli, L., Grassi, M., Grigoriev, D. N., Hildebrandt, M., Meuwly, M., Nicolò, D., Raffaelli, F., Schwendimann, P., Signorelli, G., & Venturini, A. (2023). A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1049, [168020]. https://doi.org/10.1016/j.nima.2023.168020

Vancouver

Vitali B, Papa A, Baldini AM, Benmansour H, Bianucci S, Cei F и др. A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2023 апр.;1049:168020. doi: 10.1016/j.nima.2023.168020

Author

Vitali, B. ; Papa, A. ; Baldini, A. M. и др. / A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2023 ; Том 1049.

BibTeX

@article{3a2379511bc046d0a08797ce01840281,
title = "A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter",
abstract = "The MEG II experiment aims to improve the sensitivity to μ+→e+γ down to 6×10−14, surpassing the 4.2×10−13 UL by MEG. To achieve this sensitivity the detector performances need to be assessed and monitored via dedicated calibrations. To calibrate the Liquid Xenon Calorimeter near the signal energy (52.8 MeV), photons are produced through the Charge EXchange (CEX) process π−p→nπ0(→γγ). Here we present the liquid Hydrogen target used for the CEX run 2021, during the first MEG II physics run.",
keywords = "Calibration, Charge EXchange, Liquid Xe calorimeter, Liquid hydrogen, MEG II",
author = "B. Vitali and A. Papa and Baldini, {A. M.} and H. Benmansour and S. Bianucci and F. Cei and M. Chiappini and G. Chiarello and Maso, {G. Dal} and M. Francesconi and L. Galli and M. Grassi and Grigoriev, {D. N.} and M. Hildebrandt and M. Meuwly and D. Nicol{\`o} and F. Raffaelli and P. Schwendimann and G. Signorelli and A. Venturini",
year = "2023",
month = apr,
doi = "10.1016/j.nima.2023.168020",
language = "English",
volume = "1049",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier Science B.V.",

}

RIS

TY - JOUR

T1 - A liquid hydrogen target to fully characterize the new MEG II liquid xenon calorimeter

AU - Vitali, B.

AU - Papa, A.

AU - Baldini, A. M.

AU - Benmansour, H.

AU - Bianucci, S.

AU - Cei, F.

AU - Chiappini, M.

AU - Chiarello, G.

AU - Maso, G. Dal

AU - Francesconi, M.

AU - Galli, L.

AU - Grassi, M.

AU - Grigoriev, D. N.

AU - Hildebrandt, M.

AU - Meuwly, M.

AU - Nicolò, D.

AU - Raffaelli, F.

AU - Schwendimann, P.

AU - Signorelli, G.

AU - Venturini, A.

PY - 2023/4

Y1 - 2023/4

N2 - The MEG II experiment aims to improve the sensitivity to μ+→e+γ down to 6×10−14, surpassing the 4.2×10−13 UL by MEG. To achieve this sensitivity the detector performances need to be assessed and monitored via dedicated calibrations. To calibrate the Liquid Xenon Calorimeter near the signal energy (52.8 MeV), photons are produced through the Charge EXchange (CEX) process π−p→nπ0(→γγ). Here we present the liquid Hydrogen target used for the CEX run 2021, during the first MEG II physics run.

AB - The MEG II experiment aims to improve the sensitivity to μ+→e+γ down to 6×10−14, surpassing the 4.2×10−13 UL by MEG. To achieve this sensitivity the detector performances need to be assessed and monitored via dedicated calibrations. To calibrate the Liquid Xenon Calorimeter near the signal energy (52.8 MeV), photons are produced through the Charge EXchange (CEX) process π−p→nπ0(→γγ). Here we present the liquid Hydrogen target used for the CEX run 2021, during the first MEG II physics run.

KW - Calibration

KW - Charge EXchange

KW - Liquid Xe calorimeter

KW - Liquid hydrogen

KW - MEG II

UR - https://www.scopus.com/inward/record.url?eid=2-s2.0-85146144798&partnerID=40&md5=26b95e1eecd734d205f0ce3a396f6bfb

UR - https://elibrary.ru/item.asp?id=50369320

UR - https://www.mendeley.com/catalogue/ae7a7dc6-2264-31c0-b227-b10c61b524f0/

U2 - 10.1016/j.nima.2023.168020

DO - 10.1016/j.nima.2023.168020

M3 - Article

VL - 1049

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

M1 - 168020

ER -

ID: 48700980