Standard

Wide dynamic range 500 fA sensitivity current measurement instrument. / Pelemeshko, Anatoly; Styuf, Aleksey; Prokopyev, Vitaliy et al.

In: MATEC Web of Conferences, Vol. 102, 01031, 15.03.2017.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Pelemeshko A, Styuf A, Prokopyev V, Prokopyev Y, Zadorozhny A. Wide dynamic range 500 fA sensitivity current measurement instrument. MATEC Web of Conferences. 2017 Mar 15;102:01031. doi: 10.1051/matecconf/201710201031

Author

BibTeX

@article{833119530a3b4b90a35e2919244d9b7a,
title = "Wide dynamic range 500 fA sensitivity current measurement instrument",
abstract = "Main technical features of Low Energy Charged Particle Sensor (LECPS) are described, taking into account LECPS high sensitivity, wide dynamic range, and conditions of in-flight operation on-board a satellite. LECPS input cascade is capable of current measurement as low as 1 pA within a 120 dB dynamic range, providing error level below 20%. Statistical calculations of acquired data, measuring time considerations and implementation of input cascade auto-calibration technique were applied to gain the best possible stability and accuracy over -20° to +50°C operation temperature.",
author = "Anatoly Pelemeshko and Aleksey Styuf and Vitaliy Prokopyev and Yuri Prokopyev and Alexander Zadorozhny",
year = "2017",
month = mar,
day = "15",
doi = "10.1051/matecconf/201710201031",
language = "English",
volume = "102",
journal = "MATEC Web of Conferences",
issn = "2261-236X",
publisher = "EDP Sciences",

}

RIS

TY - JOUR

T1 - Wide dynamic range 500 fA sensitivity current measurement instrument

AU - Pelemeshko, Anatoly

AU - Styuf, Aleksey

AU - Prokopyev, Vitaliy

AU - Prokopyev, Yuri

AU - Zadorozhny, Alexander

PY - 2017/3/15

Y1 - 2017/3/15

N2 - Main technical features of Low Energy Charged Particle Sensor (LECPS) are described, taking into account LECPS high sensitivity, wide dynamic range, and conditions of in-flight operation on-board a satellite. LECPS input cascade is capable of current measurement as low as 1 pA within a 120 dB dynamic range, providing error level below 20%. Statistical calculations of acquired data, measuring time considerations and implementation of input cascade auto-calibration technique were applied to gain the best possible stability and accuracy over -20° to +50°C operation temperature.

AB - Main technical features of Low Energy Charged Particle Sensor (LECPS) are described, taking into account LECPS high sensitivity, wide dynamic range, and conditions of in-flight operation on-board a satellite. LECPS input cascade is capable of current measurement as low as 1 pA within a 120 dB dynamic range, providing error level below 20%. Statistical calculations of acquired data, measuring time considerations and implementation of input cascade auto-calibration technique were applied to gain the best possible stability and accuracy over -20° to +50°C operation temperature.

UR - http://www.scopus.com/inward/record.url?scp=85016482181&partnerID=8YFLogxK

U2 - 10.1051/matecconf/201710201031

DO - 10.1051/matecconf/201710201031

M3 - Article

AN - SCOPUS:85016482181

VL - 102

JO - MATEC Web of Conferences

JF - MATEC Web of Conferences

SN - 2261-236X

M1 - 01031

ER -

ID: 9052483