Standard

Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider. / Timoshenko, M. V.; Boyarkina, V. E.; Dorokhov, V. L. et al.

In: Instruments and Experimental Techniques, Vol. 67, No. 5, 03.02.2025, p. 858-864.

Research output: Contribution to journalArticlepeer-review

Harvard

Timoshenko, MV, Boyarkina, VE, Dorokhov, VL, Krutik, MI, Meshkov, OI & Terent’ev, IA 2025, 'Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider', Instruments and Experimental Techniques, vol. 67, no. 5, pp. 858-864. https://doi.org/10.1134/S0020441224701653

APA

Timoshenko, M. V., Boyarkina, V. E., Dorokhov, V. L., Krutik, M. I., Meshkov, O. I., & Terent’ev, I. A. (2025). Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider. Instruments and Experimental Techniques, 67(5), 858-864. https://doi.org/10.1134/S0020441224701653

Vancouver

Timoshenko MV, Boyarkina VE, Dorokhov VL, Krutik MI, Meshkov OI, Terent’ev IA. Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider. Instruments and Experimental Techniques. 2025 Feb 3;67(5):858-864. doi: 10.1134/S0020441224701653

Author

Timoshenko, M. V. ; Boyarkina, V. E. ; Dorokhov, V. L. et al. / Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider. In: Instruments and Experimental Techniques. 2025 ; Vol. 67, No. 5. pp. 858-864.

BibTeX

@article{9b58253c53da48778058325ba293cdc1,
title = "Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider",
abstract = "The Nanogate‑38 gated camera was used to measure the transverse beam dimensions in the BEP booster of the VEPP‑2000 electron−positron collider. The camera is used to measure the vertical beam size by a double-slit interferometer and to visualize a transverse beam profile in single-turn mode with the projection optics. The purpose of the experiments is to assess the applicability of the camera to measurements of the transverse beam dimensions and beam emittance in accelerator experiments at the SKIF synchrotron-radiation source.",
author = "Timoshenko, {M. V.} and Boyarkina, {V. E.} and Dorokhov, {V. L.} and Krutik, {M. I.} and Meshkov, {O. I.} and Terent{\textquoteright}ev, {I. A.}",
note = "The work was supported by the Russian Science Foundation (grant no. 22-22-00-177). Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider / M. V. Timoshenko, V. E. Boyarkina, V. L. Dorokhov [et al.] // Instruments and Experimental Techniques. – 2024. – Vol. 67, No. 5. – P. 858-864. – DOI 10.1134/S0020441224701653.",
year = "2025",
month = feb,
day = "3",
doi = "10.1134/S0020441224701653",
language = "English",
volume = "67",
pages = "858--864",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "5",

}

RIS

TY - JOUR

T1 - Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider

AU - Timoshenko, M. V.

AU - Boyarkina, V. E.

AU - Dorokhov, V. L.

AU - Krutik, M. I.

AU - Meshkov, O. I.

AU - Terent’ev, I. A.

N1 - The work was supported by the Russian Science Foundation (grant no. 22-22-00-177). Use of the Nanogate‑38 Camera for Beam Diagnostics at the VEPP‑2000 Collider / M. V. Timoshenko, V. E. Boyarkina, V. L. Dorokhov [et al.] // Instruments and Experimental Techniques. – 2024. – Vol. 67, No. 5. – P. 858-864. – DOI 10.1134/S0020441224701653.

PY - 2025/2/3

Y1 - 2025/2/3

N2 - The Nanogate‑38 gated camera was used to measure the transverse beam dimensions in the BEP booster of the VEPP‑2000 electron−positron collider. The camera is used to measure the vertical beam size by a double-slit interferometer and to visualize a transverse beam profile in single-turn mode with the projection optics. The purpose of the experiments is to assess the applicability of the camera to measurements of the transverse beam dimensions and beam emittance in accelerator experiments at the SKIF synchrotron-radiation source.

AB - The Nanogate‑38 gated camera was used to measure the transverse beam dimensions in the BEP booster of the VEPP‑2000 electron−positron collider. The camera is used to measure the vertical beam size by a double-slit interferometer and to visualize a transverse beam profile in single-turn mode with the projection optics. The purpose of the experiments is to assess the applicability of the camera to measurements of the transverse beam dimensions and beam emittance in accelerator experiments at the SKIF synchrotron-radiation source.

UR - https://www.mendeley.com/catalogue/995b3815-e0c9-3d07-8985-b551ff01ff5e/

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85218216788&origin=inward&txGid=bc9eb8b29f804dc7b9409400352ee07c

UR - https://elibrary.ru/item.asp?id=80288731

U2 - 10.1134/S0020441224701653

DO - 10.1134/S0020441224701653

M3 - Article

VL - 67

SP - 858

EP - 864

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 5

ER -

ID: 64855293