Standard

The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance. / Dorokhov, V. L.; Meshkov, O. I.; Boyarkina, V. E.

Proceedings of the International Beam Instrumentation Conference, IBIC. ed. / Jianshe Cao; Junhui Yue; Lin Bian; Ivan Andrian; Volker RW Schaa; Zhichu Chen. Joint Accelerator Conferences Website (JACoW), 2024. p. 305-309 (Proceedings of the International Beam Instrumentation Conference, IBIC).

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

Harvard

Dorokhov, VL, Meshkov, OI & Boyarkina, VE 2024, The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance. in J Cao, J Yue, L Bian, I Andrian, VRW Schaa & Z Chen (eds), Proceedings of the International Beam Instrumentation Conference, IBIC. Proceedings of the International Beam Instrumentation Conference, IBIC, Joint Accelerator Conferences Website (JACoW), pp. 305-309, 13th International Beam Instrumentation Conference, Beijing, China, 09.09.2024. https://doi.org/10.18429/JACoW-IBIC2024-WEP20

APA

Dorokhov, V. L., Meshkov, O. I., & Boyarkina, V. E. (2024). The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance. In J. Cao, J. Yue, L. Bian, I. Andrian, V. RW. Schaa, & Z. Chen (Eds.), Proceedings of the International Beam Instrumentation Conference, IBIC (pp. 305-309). (Proceedings of the International Beam Instrumentation Conference, IBIC). Joint Accelerator Conferences Website (JACoW). https://doi.org/10.18429/JACoW-IBIC2024-WEP20

Vancouver

Dorokhov VL, Meshkov OI, Boyarkina VE. The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance. In Cao J, Yue J, Bian L, Andrian I, Schaa VRW, Chen Z, editors, Proceedings of the International Beam Instrumentation Conference, IBIC. Joint Accelerator Conferences Website (JACoW). 2024. p. 305-309. (Proceedings of the International Beam Instrumentation Conference, IBIC). doi: 10.18429/JACoW-IBIC2024-WEP20

Author

Dorokhov, V. L. ; Meshkov, O. I. ; Boyarkina, V. E. / The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance. Proceedings of the International Beam Instrumentation Conference, IBIC. editor / Jianshe Cao ; Junhui Yue ; Lin Bian ; Ivan Andrian ; Volker RW Schaa ; Zhichu Chen. Joint Accelerator Conferences Website (JACoW), 2024. pp. 305-309 (Proceedings of the International Beam Instrumentation Conference, IBIC).

BibTeX

@inproceedings{6994967d9563435182cc5d90dba80802,
title = "The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance",
abstract = "The Siberian Circular Photon Source (SKIF), a fourth-generation synchrotron radiation (SR) source is being constructed in Russia. This installation has an ultra-low emittance, allowing for high beam intensity in various scientific and technological fields. A crucial aspect of SKIF is its availability of diagnostic instruments that measure the beam transverse dimensions. This will allow for minimizing the emittance during operation and comparing it with a calculated value. This comparison is critical for determining whether the physical setup meets the design specifications. In addition to measuring the transverse dimensions of the beam, it is also important to observe the behaviour of the longitudinal profile and measure its parameters with good accuracy. Since the calculated emittance of 75 pm · mrad corresponds to the beam sizes of less than 8 µm at the radiation output sites, a diagnostic complex was developed as a part of the working project, including a beam size monitor based on a double-slit interferometer. Observation and measurement of the longitudinal distribution of the beam will be carried out using mutually complementary devices, such as a streak camera and electron-optical dissector.",
author = "Dorokhov, {V. L.} and Meshkov, {O. I.} and Boyarkina, {V. E.}",
note = "This work was supported by the Ministry of Science and Higher Education of the Russian Federation within the governmental order for SRF SKIF Boreskov Institute of Catalysis (project FWUR-2024-0041).; 13th International Beam Instrumentation Conference, IBIC 2024 ; Conference date: 09-09-2024 Through 13-09-2024",
year = "2024",
doi = "10.18429/JACoW-IBIC2024-WEP20",
language = "English",
series = "Proceedings of the International Beam Instrumentation Conference, IBIC",
publisher = "Joint Accelerator Conferences Website (JACoW)",
pages = "305--309",
editor = "Jianshe Cao and Junhui Yue and Lin Bian and Ivan Andrian and Schaa, {Volker RW} and Zhichu Chen",
booktitle = "Proceedings of the International Beam Instrumentation Conference, IBIC",
address = "Switzerland",

}

RIS

TY - GEN

T1 - The project of optical diagnostics of the beam dimensions of the SKIF storage ring with ultra-low emittance

AU - Dorokhov, V. L.

AU - Meshkov, O. I.

AU - Boyarkina, V. E.

N1 - Conference code: 13

PY - 2024

Y1 - 2024

N2 - The Siberian Circular Photon Source (SKIF), a fourth-generation synchrotron radiation (SR) source is being constructed in Russia. This installation has an ultra-low emittance, allowing for high beam intensity in various scientific and technological fields. A crucial aspect of SKIF is its availability of diagnostic instruments that measure the beam transverse dimensions. This will allow for minimizing the emittance during operation and comparing it with a calculated value. This comparison is critical for determining whether the physical setup meets the design specifications. In addition to measuring the transverse dimensions of the beam, it is also important to observe the behaviour of the longitudinal profile and measure its parameters with good accuracy. Since the calculated emittance of 75 pm · mrad corresponds to the beam sizes of less than 8 µm at the radiation output sites, a diagnostic complex was developed as a part of the working project, including a beam size monitor based on a double-slit interferometer. Observation and measurement of the longitudinal distribution of the beam will be carried out using mutually complementary devices, such as a streak camera and electron-optical dissector.

AB - The Siberian Circular Photon Source (SKIF), a fourth-generation synchrotron radiation (SR) source is being constructed in Russia. This installation has an ultra-low emittance, allowing for high beam intensity in various scientific and technological fields. A crucial aspect of SKIF is its availability of diagnostic instruments that measure the beam transverse dimensions. This will allow for minimizing the emittance during operation and comparing it with a calculated value. This comparison is critical for determining whether the physical setup meets the design specifications. In addition to measuring the transverse dimensions of the beam, it is also important to observe the behaviour of the longitudinal profile and measure its parameters with good accuracy. Since the calculated emittance of 75 pm · mrad corresponds to the beam sizes of less than 8 µm at the radiation output sites, a diagnostic complex was developed as a part of the working project, including a beam size monitor based on a double-slit interferometer. Observation and measurement of the longitudinal distribution of the beam will be carried out using mutually complementary devices, such as a streak camera and electron-optical dissector.

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85219754810&origin=inward&txGid=c313096c9c420b9c23153b9610c685bc

UR - https://www.mendeley.com/catalogue/a725110b-9393-3081-a22f-a54362799cd9/

U2 - 10.18429/JACoW-IBIC2024-WEP20

DO - 10.18429/JACoW-IBIC2024-WEP20

M3 - Conference contribution

T3 - Proceedings of the International Beam Instrumentation Conference, IBIC

SP - 305

EP - 309

BT - Proceedings of the International Beam Instrumentation Conference, IBIC

A2 - Cao, Jianshe

A2 - Yue, Junhui

A2 - Bian, Lin

A2 - Andrian, Ivan

A2 - Schaa, Volker RW

A2 - Chen, Zhichu

PB - Joint Accelerator Conferences Website (JACoW)

T2 - 13th International Beam Instrumentation Conference

Y2 - 9 September 2024 through 13 September 2024

ER -

ID: 65075347