Research output: Contribution to journal › Article › peer-review
The porosity and nuclear magnetic characteristics of artificial samples with the equal grain size. / Yanushenko, Timofey A.; Golikov, Nikita A.
In: Bulletin of the Tomsk Polytechnic University, Geo Assets Engineering, Vol. 336, No. 5, 2025, p. 110-119.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - The porosity and nuclear magnetic characteristics of artificial samples with the equal grain size
AU - Yanushenko, Timofey A.
AU - Golikov, Nikita A.
N1 - The research was carried out within the framework of the state assignment of the Ministry of Education and Science of the Russian Federation, the project FWZZ-2022-0026. Yanushenko T.A., Golikov N.A. The porosity and nuclear magnetic characteristics of artificial samples with the equal grain size. Bulletin of the Tomsk Polytechnic University. Geo Assets Engineering, 2025, vol. 336, no. 5, pp. 110–119. DOI: 10.18799/24131830/2025/5/4723
PY - 2025
Y1 - 2025
N2 - Relevance. The nuclear magnetic resonance relaxometry is a fairly new method for well logging and laboratory investigations. It is applied for determining petrophysical properties, e.g., porosity, permeability, water- and oil-saturation. However, the nuclear magnetic resonance relaxometry data interpretation rests on the representation of the pore space as a set of spheres of various diameters that fundamentally does not correspond to the structure of granular rocks. Aim. To examine an influence of grain size on the measurements results of nuclear magnetic resonance relaxometry porosity and compare with other conventional methods. Objects. Artificial samples made with various sand and quartz glass beads fractions. Methods. Water-saturation, gas-volumetric and nuclear magnetic resonance relaxometry were applied to determine porosity. X-ray diffraction method was used to clarify the mineralogical composition; to measure the grain size a laser particle size analyzer was used, and the grain shape was investigated in polished specimens. Results. The paper describes the results of porosity measurements with different methods for artificial samples. We observed an effect of underestimated porosity acquired with nuclear magnetic resonance relaxometry method for consolidated and unconsolidated samples with grain size less than 0.160 mm. The investigation of sand composition with the X-ray diffraction method and additional assessment of the particles shape and size led to conclude that these factors are not the cause of the underestimated porosity effect. Additional statistical samples and using of the other nuclear magnetic resonance relaxometer presented the reparability of previous results. Based on the research results, it was assumed that the cause of the underestimated porosity effect is the complex shape and increased specific surface area of the samples, which grows as the particle size decreases.
AB - Relevance. The nuclear magnetic resonance relaxometry is a fairly new method for well logging and laboratory investigations. It is applied for determining petrophysical properties, e.g., porosity, permeability, water- and oil-saturation. However, the nuclear magnetic resonance relaxometry data interpretation rests on the representation of the pore space as a set of spheres of various diameters that fundamentally does not correspond to the structure of granular rocks. Aim. To examine an influence of grain size on the measurements results of nuclear magnetic resonance relaxometry porosity and compare with other conventional methods. Objects. Artificial samples made with various sand and quartz glass beads fractions. Methods. Water-saturation, gas-volumetric and nuclear magnetic resonance relaxometry were applied to determine porosity. X-ray diffraction method was used to clarify the mineralogical composition; to measure the grain size a laser particle size analyzer was used, and the grain shape was investigated in polished specimens. Results. The paper describes the results of porosity measurements with different methods for artificial samples. We observed an effect of underestimated porosity acquired with nuclear magnetic resonance relaxometry method for consolidated and unconsolidated samples with grain size less than 0.160 mm. The investigation of sand composition with the X-ray diffraction method and additional assessment of the particles shape and size led to conclude that these factors are not the cause of the underestimated porosity effect. Additional statistical samples and using of the other nuclear magnetic resonance relaxometer presented the reparability of previous results. Based on the research results, it was assumed that the cause of the underestimated porosity effect is the complex shape and increased specific surface area of the samples, which grows as the particle size decreases.
KW - artificial samples
KW - gas-volumetric method
KW - grain size
KW - nuclear magnetic resonance relaxometry
KW - petrophysical properties
KW - porosity
KW - water-saturating method
UR - https://www.mendeley.com/catalogue/4d82e434-79b9-30d1-8208-727b1d8d64ce/
UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-105007352301&origin=inward&txGid=64523430c80ce39d29dd1ebfbccdee0d
U2 - 10.18799/24131830/2025/5/4723
DO - 10.18799/24131830/2025/5/4723
M3 - Article
VL - 336
SP - 110
EP - 119
JO - Известия Томского политехнического университета. Инжиниринг георесурсов
JF - Известия Томского политехнического университета. Инжиниринг георесурсов
SN - 2500-1019
IS - 5
ER -
ID: 67894522