Standard

Study of the spatial resolution of low-material GEM tracking detectors. / Kudryavtsev, V. N.; Maltsev, T. V.; Shekhtman, L. I.

In: EPJ Web of Conferences, Vol. 174, 06005, 21.02.2018.

Research output: Contribution to journalConference articlepeer-review

Harvard

APA

Vancouver

Kudryavtsev VN, Maltsev TV, Shekhtman LI. Study of the spatial resolution of low-material GEM tracking detectors. EPJ Web of Conferences. 2018 Feb 21;174:06005. doi: 10.1051/epjconf/201817406005

Author

BibTeX

@article{3f1ef597e58645bbb911b46c34d53292,
title = "Study of the spatial resolution of low-material GEM tracking detectors",
abstract = "The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes. electronics noise and a particular algorithm of the final coordinate calculation (center of gravity). The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2 Ax 10{"}3 corresponding to a thickness of the copper layers of the GEM foils of 3 fjm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.",
author = "Kudryavtsev, {V. N.} and Maltsev, {T. V.} and Shekhtman, {L. I.}",
year = "2018",
month = feb,
day = "21",
doi = "10.1051/epjconf/201817406005",
language = "English",
volume = "174",
journal = "EPJ Web of Conferences",
issn = "2101-6275",
publisher = "EDP Sciences",

}

RIS

TY - JOUR

T1 - Study of the spatial resolution of low-material GEM tracking detectors

AU - Kudryavtsev, V. N.

AU - Maltsev, T. V.

AU - Shekhtman, L. I.

PY - 2018/2/21

Y1 - 2018/2/21

N2 - The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes. electronics noise and a particular algorithm of the final coordinate calculation (center of gravity). The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2 Ax 10"3 corresponding to a thickness of the copper layers of the GEM foils of 3 fjm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

AB - The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes. electronics noise and a particular algorithm of the final coordinate calculation (center of gravity). The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2 Ax 10"3 corresponding to a thickness of the copper layers of the GEM foils of 3 fjm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

UR - http://www.scopus.com/inward/record.url?scp=85043260678&partnerID=8YFLogxK

U2 - 10.1051/epjconf/201817406005

DO - 10.1051/epjconf/201817406005

M3 - Conference article

AN - SCOPUS:85043260678

VL - 174

JO - EPJ Web of Conferences

JF - EPJ Web of Conferences

SN - 2101-6275

M1 - 06005

ER -

ID: 10452225